VERIFICATION OF FORCE TRANSDUCER FOR DIRECT AND INDIRECT MEASUREMENTS

被引:14
|
作者
Kelemenova, Tatiana [1 ]
Dovica, Miroslav
Kolarikova, Ivana
Benedik, Ondrej
Maxim, Vladislav
机构
[1] Tech Univ Kosice, Fac Mech Engn, Kosice, Slovakia
来源
MM SCIENCE JOURNAL | 2021年 / 2021卷
关键词
Force sensor; measurement; calibration; reference standard; verification; uncertainty; measurement error; CALIBRATION; SENSOR;
D O I
10.17973/MMSJ.2021_10_2021021
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Paper deals with verification of high load force sensor using the small weight weights. Test band was built for this purpose. Verification of test band were executed using the etalon reference sensor. Small forces were executed via using the direct method through the applying of weights. High forces were executed using the indirect method through the lever amplification of load derived from small weights. Uncertainties of measurement were evaluated.
引用
收藏
页码:4736 / 4742
页数:7
相关论文
共 50 条
  • [41] INTERACTION OF FLUORIDE AND BACTERIA EVALUATED BY DIRECT AND INDIRECT MEASUREMENTS
    BIRKELAN.JM
    CARIES RESEARCH, 1972, 6 (03) : 258 - &
  • [42] DIRECT AND INDIRECT MEASUREMENTS OF MARKSTEIN NUMBERS OF PREMIXED FLAMES
    SEARBY, G
    QUINARD, J
    COMBUSTION AND FLAME, 1990, 82 (3-4) : 298 - 311
  • [43] DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENTS IN BABOONS
    MCMAHAN, CA
    WIGODSKY, HS
    MOORE, GT
    JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (05) : 806 - 809
  • [44] Reliability of direct and indirect clinical attachment level measurements
    Corraini, Priscila
    Baelum, Vibeke
    Lopez, Rodrigo
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2013, 40 (09) : 896 - 905
  • [45] Direct and Indirect Measurements for a Better Understanding of the Primordial Nucleosynthesis
    Sparta, Roberta
    Pizzone, Rosario Gianluca
    Bertulani, Carlos A.
    Hou, Suqing
    Lamia, Livio
    Tumino, Aurora
    FRONTIERS IN ASTRONOMY AND SPACE SCIENCES, 2020, 7
  • [46] The importance of structural coupling effects on force-moment transducer measurements
    Dong, JR
    McConnell, KG
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 1106 - 1110
  • [47] Orthogonal superposition measurements using a rheometer equipped with a force rebalanced transducer
    Vermant, J
    Moldenaers, P
    Mewis, J
    Ellis, M
    Garritano, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (11): : 4090 - 4096
  • [48] COMPARISON OF THE DIRECT AND INDIRECT EFFECTS OF ANDROMEDOTOXIN ON THE CONTRACTILE FORCE OF THE HEART
    COTTEN, MD
    MALING, HM
    MORAN, NC
    JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 1956, 118 (01): : 55 - 62
  • [49] MEASUREMENTS OF SHOCK WAVE FORCE IN SHOCK TUBE WITH INDIRECT METHODS
    Dobrilovic, Mario
    Ester, Zvonimir
    Kujundzic, Trpimir
    RUDARSKO-GEOLOSKO-NAFTNI ZBORNIK, 2005, 17 (01): : 55 - 60
  • [50] Wind load based on direct force measurements
    Mihanovic, Ante
    Nikolic, Zeljana
    Trogrlic, Boris
    GRADEVINAR, 2010, 62 (02): : 105 - 112