VERIFICATION OF FORCE TRANSDUCER FOR DIRECT AND INDIRECT MEASUREMENTS

被引:11
|
作者
Kelemenova, Tatiana [1 ]
Dovica, Miroslav
Kolarikova, Ivana
Benedik, Ondrej
Maxim, Vladislav
机构
[1] Tech Univ Kosice, Fac Mech Engn, Kosice, Slovakia
来源
MM SCIENCE JOURNAL | 2021年 / 2021卷
关键词
Force sensor; measurement; calibration; reference standard; verification; uncertainty; measurement error; CALIBRATION; SENSOR;
D O I
10.17973/MMSJ.2021_10_2021021
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Paper deals with verification of high load force sensor using the small weight weights. Test band was built for this purpose. Verification of test band were executed using the etalon reference sensor. Small forces were executed via using the direct method through the applying of weights. High forces were executed using the indirect method through the lever amplification of load derived from small weights. Uncertainties of measurement were evaluated.
引用
收藏
页码:4736 / 4742
页数:7
相关论文
共 50 条
  • [1] DIRECT AND INDIRECT MEASUREMENTS OF HYDROGEN
    LEVINE, TE
    NASTASI, M
    WALTER, KC
    TESMER, JR
    MAGGIORE, CJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 103 (03): : 359 - 361
  • [2] Methodology for replacing indirect measurements with direct measurements
    Mitarai, Kosuke
    Fujii, Keisuke
    [J]. PHYSICAL REVIEW RESEARCH, 2019, 1 (01):
  • [3] Calibration Issues for Nanoindentation Experiments: Direct Atomic Force Microscopy Measurements and Indirect Methods
    Barone, A. C.
    Salerno, M.
    Patra, N.
    Gastaldi, D.
    Bertarelli, E.
    Carnelli, D.
    Vena, P.
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2010, 73 (10) : 996 - 1004
  • [4] MINIATURE TRANSDUCER FOR CHORDAL FORCE MEASUREMENTS IN VIVO
    Askov, J. B.
    Jensen, M. O.
    Honge, J. L.
    Nygaard, H.
    Hasenkam, J. M.
    Nielsen, S. L.
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 617 - 618
  • [5] DIRECT AND INDIRECT MEASUREMENTS OF OXYGEN RADICALS
    SARAN, M
    BORS, W
    [J]. KLINISCHE WOCHENSCHRIFT, 1991, 69 (21-23): : 957 - 964
  • [6] INTRALUMINAL FORCE TRANSDUCER MEASUREMENTS OF HUMAN ESOPHAGEAL PERISTALSIS
    POPE, CE
    HORTON, PF
    [J]. GUT, 1972, 13 (06) : 464 - &
  • [7] On the direct or indirect measurement of force in vibration testing
    Wright, JR
    Skingle, GW
    [J]. PROCEEDINGS OF THE 15TH INTERNATIONAL MODAL ANALYSIS CONFERENCE - IMAC, VOLS I AND II, 1997, 3089 : 1360 - 1370
  • [8] Force and location between direct and indirect laryngoscopes
    Yukihiro Imajo
    Nobuyasu Komasawa
    Toshiaki Minami
    [J]. Journal of Anesthesia, 2016, 30 : 362 - 362
  • [9] Force and location between direct and indirect laryngoscopes
    Imajo, Yukihiro
    Komasawa, Nobuyasu
    Minami, Toshiaki
    [J]. JOURNAL OF ANESTHESIA, 2016, 30 (02) : 362 - 362
  • [10] DIRECT SINOATRIAL CONDUCTION TIME - VERIFICATION OF INDIRECT METHODS
    TRUSZGLUZA, M
    DRZEWIECKI, J
    GIEC, L
    SZULC, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A12 - A12