Effects Of a Ceiling Diffuser On Diffuse Ceiling Ventilation (DCV) Performance

被引:1
|
作者
Nocente, Alessandro [1 ,2 ]
Arslan, Tufan [1 ]
Grynning, Steinar [2 ]
Goia, Francesco [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Trondheim, Norway
[2] SINTEF Bldg & Infrastruct, Trondheim, Norway
关键词
D O I
10.26868/25222708.2019.210297
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Diffuse Ceiling Ventilation (DCV) is a promising concept to address the internal comfort requirements in modern buildings. Among various possible configuration, the use of sound absorbing perforated panels is the most attractive since it does not require substantial modification in the design of the suspended ceilings normally present in office room. Numerical simulations are a valuable tool to evaluate the performance of a DCV avoiding the cost of an experimental campaign. As today, all the numerical studies are usually carried out by modeling the perforated ceiling as a porous medium, focusing more on its general performance than on the optimisation of the diffuser design. In a previous study by the authors, a CFD model was used to optimise the size and distribution of the dropped ceiling perforation in a room section, modeling the actual perforation of panels. This paper presents the results of simulations carried out using of a full scale numerical model of an office room with DCV with focus on the performance comparison between a continuous and non-continuous ceiling diffuser surface. The results show that the noncontinuous diffuser design does not affect the internal comfort. The air velocity distribution in the room is far below the discomfort limit. In addition, the noncontinuous system does not introduce a significant increase in the total pressure loss of the ventilation system.
引用
下载
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [21] Experimental investigation of convective heat transfer for night cooling with diffuse ceiling ventilation
    Guo, Rui
    Heiselberg, Per
    Hu, Yue
    Johra, Hicham
    Zhang, Chen
    Jensen, Rasmus Lund
    Jonsson, Kim Trangbaek
    Peng, Pei
    BUILDING AND ENVIRONMENT, 2021, 193
  • [22] THE INFLUENCE OF A PERFORATED FALSE CEILING ON THE PERFORMANCE OF SMOKE VENTILATION SYSTEMS
    MARSHALL, NR
    FENG, SQ
    MORGAN, HP
    FIRE SAFETY JOURNAL, 1985, 8 (03) : 227 - 237
  • [23] Performance comparison between mixing ventilation and displacement ventilation with and without cooled ceiling
    Wang, Qiu-Wang
    Zhao, Zhen
    ENGINEERING COMPUTATIONS, 2006, 23 (3-4) : 218 - 237
  • [24] Experimental investigation of cooling performance of a novel HVAC system combining natural ventilation with diffuse ceiling inlet and TABS
    Yu, Tao
    Heiselberg, Per
    Lei, Bo
    Pomianowski, Michal
    Zhang, Chen
    Jensen, Rasmus
    ENERGY AND BUILDINGS, 2015, 105 : 165 - 177
  • [25] BAFFLED CENTER CEILING VENTILATION INLET
    HELLICKSON, MA
    YOUNG, HG
    WITMER, WB
    TRANSACTIONS OF THE ASAE, 1973, 16 (04): : 758 - 760
  • [26] Field study evaluation of diffuse ceiling ventilation in classroom during real operating conditions
    Kristensen, Martin Heine
    Jensen, Jakob Soland
    Heiselberg, Per Kvols
    ENERGY AND BUILDINGS, 2017, 138 : 26 - 34
  • [27] Integrated solution in an office room with diffuse ceiling ventilation and thermally activated building constructions
    Zhang, Chen
    Heiselberg, Per Kvols
    Pomianowski, Michal
    Yu, Tao
    Jensen, Rasmus Lund
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2808 - 2813
  • [28] Effect of natural ventilation and wind direction on the thermal performance of a building ceiling
    Ali, Abdel Aziz Ali
    Milad, Guiremis Nabil
    Ali, Hassan Mafirnoud
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 410 - 414
  • [29] Investigation on indoor airflow and contaminant dispersion of diffuse ceiling ventilation in heating and cooling modes
    Peng, Pei
    Zhang, Chen
    Li, Wenqiang
    Pomianowski, Michal
    Gong, Guangcai
    Fang, Xi
    Chun, Liang
    Guo, Rui
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [30] A novel solution for school renovations: Combining diffuse ceiling ventilation with double skin facade
    Bugenings, Laura Annabelle
    Schaffer, Markus
    Larsen, Olena Kalyanova
    Zhang, Chen
    JOURNAL OF BUILDING ENGINEERING, 2022, 49