Determination of drop size distributions in a continuous mixer

被引:0
|
作者
Ruiz, MC [1 ]
Müller, X [1 ]
Padilla, R [1 ]
机构
[1] Concepcion Univ, Dept Met Engn, Concepcion, Chile
来源
关键词
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
In the present study, the size distribution, F-0(v), of organic drops produced in a continuous-mixing vessel has been determined experimentally for various conditions. The organic phase used was a 1:1 mixture of a salicylaldoxime (LIX 860N-IC) and a ketoxime (LIX 64-IC) in an aliphatic diluent (Escaid 103). The aqueous phase was a copper sulfate solution. The results indicated that an increase in stirring speed, extractant concentration, and pH produced smaller drops. The effect of the stirring speed was the most significant, decreasing the average volume of drops by 57 % for a change from 300 to 400 rpm. On the contrary, an increase in the dispersed phase fraction, copper sulfate concentration, and retention time produced larger drops. Changes in temperature from 23 to 30 degreesC did not affect significantly the drop sizes. In all cases, the experimental drop size distributions could be accurately represented by a lognormal distribution.
引用
收藏
页码:371 / 383
页数:13
相关论文
共 50 条
  • [21] Primary Modes of Global Drop Size Distributions
    Dolan, B.
    Fuchs, B.
    Rutledge, S. A.
    Barnes, E. A.
    Thompson, E. J.
    JOURNAL OF THE ATMOSPHERIC SCIENCES, 2018, 75 (05) : 1453 - 1476
  • [22] MEASUREMENTS OF CLOUD DROP-SIZE DISTRIBUTIONS
    ELDRIDGE, RG
    JOURNAL OF METEOROLOGY, 1957, 14 (01): : 55 - 59
  • [24] Shock-induced drop size and distributions
    Park, J. E.
    Lee, T. -w.
    COMBUSTION AND FLAME, 2025, 275
  • [25] Drop size distributions in liquid pulsed columns
    Sreenivasulu, K
    Venkatanarasaiah, D
    Varma, YBG
    BIOPROCESS ENGINEERING, 1997, 17 (03) : 189 - 195
  • [26] THE DEVELOPMENT OF DROP SIZE DISTRIBUTIONS IN LIGHT RAIN
    ZAWADZKI, I
    MONTEIRO, E
    FABRY, F
    JOURNAL OF THE ATMOSPHERIC SCIENCES, 1994, 51 (08) : 1100 - 1113
  • [27] DETERMINATION OF SUBMICRON ATMOSPHERIC AEROSOL SIZE DISTRIBUTIONS BY USE OF CONTINUOUS ANALOG SENSORS
    SVERDRUP, GM
    WHITBY, KT
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (13) : 1171 - 1176
  • [28] Drop-size distributions and spatial distributions in an annular centrifugal contactor
    Wyatt, Nicholas B.
    O'Hern, Timothy J.
    Shelden, Bion
    AICHE JOURNAL, 2013, 59 (06) : 2219 - 2226
  • [29] Measurement and analysis of drop size in a batch rotor-stator mixer
    Calabrese, RV
    Francis, MK
    Mishra, VP
    Phongikaroon, S
    10TH EUROPEAN CONFERENCE ON MIXING, 2000, : 149 - 156
  • [30] The effects of a surfactant on mean drop size in a mixer-settler extractor
    Khakpay, Amir
    Abolghasemi, Hossein
    Salimi-Khorshidi, Ali
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (06) : 1105 - 1111