Stereotactic target localization accuracy in interventional magnetic resonance imaging

被引:3
|
作者
Samset, E [1 ]
Hirschberg, H
机构
[1] Univ Oslo, Rikshosp, Intervent Ctr, Natl Hosp Norway, NO-0027 Oslo, Norway
[2] Univ Oslo, Natl Hosp Norway, Dept Neurosurg, NO-0027 Oslo, Norway
关键词
functional stereotactic surgery; accuracy; magnetic resonance imaging; target determination;
D O I
10.1159/000070832
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: To compare stereotactic target determination, based on images obtained from interventional MRI (iMRI), conventional closed MR and CT. Methods: Stereotactic coordinates for 55 targets in an artificial scull were derived from iMRI scans and compared using CT as the standard. Stereotactic coordinates were also derived from iMRI scans in a series of patients and compared using iMRI fused with CT as the standard. Results: The mean difference between targets in the skull phantom determined from iMRI and CT images was 0.90 +/- 0.28 mm, with a maximum difference of 1.57 mm. The mean difference between targets in the patients derived from iMRI alone and interventional MR fused with CT was 1.39 +/- 0.54 mm, with a maximum difference of 2.47 mm. Discussion: The results indicate that iMRI can be used for stereotactic target localization. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [21] Interventional magnetic resonance imaging
    Jolesz, FA
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 599 - 603
  • [22] Measurement of Lead Localization Accuracy Based on Magnetic Resonance Imaging
    He, Changgeng
    Zhang, Feng
    Li, Linze
    Jiang, Changqing
    Li, Luming
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [24] Accuracy of Frame-Based Stereotactic Magnetic Resonance Imaging vs Frame-Based Stereotactic Head Computed Tomography Fused With Recent Magnetic Resonance Imaging for Postimplantation Deep Brain Stimulator Lead Localization
    Pezeshkian, Patrick
    DeSalles, Antonio A. F.
    Gorgulho, Alessandra
    Behnke, Eric
    McArthur, David
    Bari, Ausaf
    NEUROSURGERY, 2011, 69 (06) : 1299 - 1306
  • [25] Interventional cardiac magnetic resonance imaging
    Weber, OM
    Schalla, S
    Martin, AJ
    Saeed, M
    Lee, R
    Shunk, KA
    Moore, P
    Higgins, CB
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (04) : 352 - 357
  • [26] Endovascular interventional magnetic resonance imaging
    Bartels, LW
    Bakker, CJG
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14): : R37 - R64
  • [27] Focus on interventional magnetic resonance imaging
    Partain, C. Leon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) : 251 - 251
  • [28] Interventional magnetic resonance imaging of the brain
    Kahn, T
    Schwarzmaier, HJ
    Mödder, U
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1999, 16 (01) : 51 - 61
  • [29] Cardiovascular interventional magnetic resonance imaging
    Lederman, RJ
    CIRCULATION, 2005, 112 (19) : 3009 - 3017
  • [30] Interventional cardiovascular magnetic resonance imaging
    Raman, Venkatesh K.
    Lederman, Robert J.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2007, 17 (06) : 196 - 202