Time-Resolved Absolute Velocity Quantification With Projections

被引:13
|
作者
Langham, Michael C. [1 ]
Jain, Varsha [1 ]
Magland, Jeremy F. [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Med Ctr, MRI Educ Ctr, Lab Struct NMR Imaging,Dept Radiol, Philadelphia, PA 19104 USA
关键词
velocity quantification; projections; non-triggered PC-MRI; PHASE-CONTRAST FLOW; REAL-TIME; BLOOD-FLOW; REACTIVE HYPEREMIA; ARTERIAL-DISEASE; LOWER-EXTREMITY; ISCHEMIA;
D O I
10.1002/mrm.22559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative information on time-resolved blood velocity along the femoral/popliteal artery can provide clinical information on peripheral arterial disease and complement MR angiography as not all stenoses are hemodynamically significant. The key disadvantages of the most widely used approach to time-resolve pulsatile blood flow by cardiac-gated velocity-encoded gradient-echo imaging are gating errors and long acquisition time. Here, we demonstrate a rapid nontriggered method that quantifies absolute velocity on the basis of phase difference between successive velocity-encoded projections after selectively removing the background static tissue signal via a reference image. The tissue signal from the reference image's center k-space line is isolated by masking out the vessels in the image domain. The performance of the technique, in terms of reproducibility and agreement with results obtained with conventional phase contrast-MRI was evaluated at 3 T field strength with a variable-flow rate phantom and in vivo of the triphasic velocity waveforms at several segments along the femoral and popliteal arteries. Additionally, time-resolved flow velocity was quantified in five healthy subjects and compared against gated phase contrast-MRI results. To illustrate clinical feasibility, the proposed method was shown to be able to identify hemodynamic abnormalities and impaired reactivity in a diseased femoral artery. For both phantom and in vivo studies, velocity measurements were within 1.5 cm/s, and the coefficient of variation was less than 5% in an in vivo reproducibility study. In five healthy subjects, the average differences in mean peak velocities and their temporal locations were within 1 cm/s and 10 ms compared to gated phase contrast-MRI. In conclusion, the proposed method provides temporally resolved arterial velocity with a temporal resolution of 20 ms with minimal post processing. Magn Reson Med 64:1599-1606, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1599 / 1606
页数:8
相关论文
共 50 条
  • [31] Quantification of endospores in ancient permafrost using time-resolved terbium luminescence
    Lalla, S. J.
    Kaneshige, K. R.
    Miller, D. R.
    Mackelprang, R.
    Mogul, R.
    [J]. ANALYTICAL BIOCHEMISTRY, 2021, 612
  • [32] Mass Spectrometry-Based Analysis of Time-Resolved Proteome Quantification
    Valdes, Alberto
    Bergstroem Lind, Sara
    [J]. PROTEOMICS, 2020, 20 (09)
  • [33] QUANTIFICATION OF NUCLEIC-ACIDS ON NITROCELLULOSE MEMBRANES WITH TIME-RESOLVED FLUOROMETRY
    CHRISTOPOULOS, TK
    DIAMANDIS, EP
    WILSON, G
    [J]. NUCLEIC ACIDS RESEARCH, 1991, 19 (21) : 6015 - 6019
  • [34] Quantification of cystatin C by time-resolved fluorometry-based immunoassays
    Ristiniemi, Noora
    Qin, Qiu-Ping
    Lindstrom, Veronica
    Grubb, Anders
    Pettersson, Kim
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2012, 378 (1-2) : 56 - 61
  • [35] Magnetophoretic Velocity Determined by Space- and Time-Resolved Extinction Profiles
    Mykhaylyk, Olga
    Lerche, Dietmar
    Vlaskou, Dialechti
    Schoemig, Veronika
    Detloff, Torsten
    Krause, Daniel
    Wolff, Markus
    Joas, Timo
    Berensmeier, Sonja
    Plank, Christian
    [J]. IEEE MAGNETICS LETTERS, 2015, 6
  • [36] The time-resolved visualization of first and second derivatives of turbulent velocity field
    Zhang, Y
    [J]. INTERNATIONAL CONFERENCE ON OPTICAL METHODS AND DATA PROCESSING IN HEAT AND FLUID FLOW, 1998, 1998 (02): : 43 - 49
  • [37] Imaginary particle tracking accelerometry based on time-resolved velocity fields
    Zhongyi Wang
    Qi Gao
    Chong Pan
    Lihao Feng
    Jinjun Wang
    [J]. Experiments in Fluids, 2017, 58
  • [38] Application of a time-resolved event counting technique in velocity map imaging
    Dinu, L
    Eppink, ATJB
    Rosca-Pruna, F
    Offerhaus, HL
    van der Zande, WJ
    Vrakking, MJJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (12): : 4206 - 4213
  • [39] Time-resolved electroabsorption measurement of the transient electron velocity overshoot in GaN
    Wraback, M
    Shen, H
    Carrano, JC
    Collins, CJ
    Campbell, JC
    Dupuis, RD
    Schurman, MJ
    Ferguson, IT
    [J]. APPLIED PHYSICS LETTERS, 2001, 79 (09) : 1303 - 1305
  • [40] FEMTOSECOND DESORPTION DYNAMICS PROBED BY TIME-RESOLVED VELOCITY-MEASUREMENTS
    BUSCH, DG
    GAO, SW
    PELAK, RA
    BOOTH, MF
    HO, W
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (04) : 673 - 676