Time-Resolved Absolute Velocity Quantification With Projections

被引:13
|
作者
Langham, Michael C. [1 ]
Jain, Varsha [1 ]
Magland, Jeremy F. [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Med Ctr, MRI Educ Ctr, Lab Struct NMR Imaging,Dept Radiol, Philadelphia, PA 19104 USA
关键词
velocity quantification; projections; non-triggered PC-MRI; PHASE-CONTRAST FLOW; REAL-TIME; BLOOD-FLOW; REACTIVE HYPEREMIA; ARTERIAL-DISEASE; LOWER-EXTREMITY; ISCHEMIA;
D O I
10.1002/mrm.22559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative information on time-resolved blood velocity along the femoral/popliteal artery can provide clinical information on peripheral arterial disease and complement MR angiography as not all stenoses are hemodynamically significant. The key disadvantages of the most widely used approach to time-resolve pulsatile blood flow by cardiac-gated velocity-encoded gradient-echo imaging are gating errors and long acquisition time. Here, we demonstrate a rapid nontriggered method that quantifies absolute velocity on the basis of phase difference between successive velocity-encoded projections after selectively removing the background static tissue signal via a reference image. The tissue signal from the reference image's center k-space line is isolated by masking out the vessels in the image domain. The performance of the technique, in terms of reproducibility and agreement with results obtained with conventional phase contrast-MRI was evaluated at 3 T field strength with a variable-flow rate phantom and in vivo of the triphasic velocity waveforms at several segments along the femoral and popliteal arteries. Additionally, time-resolved flow velocity was quantified in five healthy subjects and compared against gated phase contrast-MRI results. To illustrate clinical feasibility, the proposed method was shown to be able to identify hemodynamic abnormalities and impaired reactivity in a diseased femoral artery. For both phantom and in vivo studies, velocity measurements were within 1.5 cm/s, and the coefficient of variation was less than 5% in an in vivo reproducibility study. In five healthy subjects, the average differences in mean peak velocities and their temporal locations were within 1 cm/s and 10 ms compared to gated phase contrast-MRI. In conclusion, the proposed method provides temporally resolved arterial velocity with a temporal resolution of 20 ms with minimal post processing. Magn Reson Med 64:1599-1606, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1599 / 1606
页数:8
相关论文
共 50 条
  • [1] Automated Quantification of Blood Flow Velocity from Time-Resolved CT Angiography
    Boonen, Pieter Thomas
    Buls, Nico
    Van Gompel, Gert
    De Brucker, Yannick
    Aerden, Dimitri
    De Mey, Johan
    Vandemeulebroucke, Jef
    [J]. INTRAVASCULAR IMAGING AND COMPUTER ASSISTED STENTING AND LARGE-SCALE ANNOTATION OF BIOMEDICAL DATA AND EXPERT LABEL SYNTHESIS, 2018, 11043 : 11 - 18
  • [2] Time-resolved MR angiography with limited projections
    Huang, Yuexi
    Wright, Graham A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 316 - 325
  • [3] ABSOLUTE INTENSITY CALIBRATION OF A TIME-RESOLVED SPECTROGRAM
    BRONFIN, BR
    MCLEAN, EA
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1962, 52 (02) : 224 - &
  • [4] Contrast Flow Velocity Quantification from Time-Resolved CT Angiography, a Phantom Study
    Boonen, Pieter Thomas
    Buls, Nico
    Van Gompel, Gert
    De Brucker, Yannick
    Aerden, Dimitri
    Leiner, Tim
    de Mey, Johan
    Vandemeulebroucke, Jef
    [J]. MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [5] Time-resolved velocity measurements in a magnetic micromixer
    Ergin, F. Gokhan
    Watz, Bo B.
    Erglis, Kaspars
    Cebers, Andrejs
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 67 : 6 - 13
  • [6] VELOCITY INTERFEROMETRY FOR TIME-RESOLVED HIGH-VELOCITY MEASUREMENTS
    BARKER, LM
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 427 : 116 - 126
  • [7] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR THE QUANTIFICATION OF LIPOPROTEIN(A) IN SERUM
    MISSLER, U
    WALEK, T
    STANGE, E
    [J]. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1995, 33 (11): : 805 - 812
  • [8] Time-resolved velocity and pressure field quantification in a flow-focusing device for ultrafast microbubble production
    Cleve, Sarah
    Diddens, Christian
    Segers, Tim
    Lajoinie, Guillaume
    Versluis, Michel
    [J]. PHYSICAL REVIEW FLUIDS, 2021, 6 (11)
  • [9] INSTRUMENTATION FOR TIME-RESOLVED MEASUREMENT OF ULTRASOUND VELOCITY DEVIATION
    ANDERSON, WL
    JENSEN, CE
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (04) : 913 - 916
  • [10] Time-resolved velocity of a domain wall in a magnetic microwire
    Calle, E.
    Jimenez, A.
    Vazquez, M.
    del Real, R. P.
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 767 : 106 - 111