Non-steady response of BOD biosensor for the determination of biochemical oxygen demand in wastewater

被引:4
|
作者
Velling, Siiri [1 ]
Mashirin, Alexey [1 ]
Hellat, Karin [1 ]
Tenno, Toomas [1 ]
机构
[1] Univ Tartu, Inst Chem, Ravila 14A, EE-50411 Tartu, Estonia
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2011年 / 13卷 / 01期
关键词
THERMALLY KILLED CELLS; ARXULA-ADENINIVORANS; MICROBIAL MEMBRANE; SENSOR; LOAD;
D O I
10.1039/c0em00082e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biochemical oxygen demand (BOD) biosensor for effective and expeditious BOD7 estimations was constructed and the non-steady phase of the output signal was extensively studied. The modelling approach introduced allows response curve reconstruction and a curve fitting procedure of good quality, resulting in parameters indicating the relationship between response and organic substrate concentration and stability properties of the BOD biosensor. Also, the immobilization matrixes of different thicknesses were characterized to determine their suitability for bio-sensing measurements in non-stationary conditions, as well as for the determination of the mechanical durability of the BOD biosensor in time. The non-steady response of the experimental output of the BOD biosensor was fitted according to the developed model that enables to determine the stability of the biosensor output and dependency on biodegradable organic substrate concentration. The calibration range of the studied BOD biosensor in OECD synthetic wastewater was 15-110 mg O-2 L-1. Repeatability tests showed relative standard deviation (RSD) values of 2.8% and 5.8% for the parameter tau(d), characterizing the transient output of the amperometric oxygen sensor in time, and tau(s), describing the dependency of the transient response of the BOD biosensor on organic substrate concentration, respectively. BOD biosensor experiments for the evaluation of the biochemical oxygen demand of easily degradable and refractory municipal wastewater showed good concurrence with traditional BOD7 analysis.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [21] Determining the total amount of oxygen consumption in effluent via carbonaceous biochemical oxygen demand (CBOD) and biochemical oxygen demand (BOD)
    Leong, Julie
    Jacques, Faye
    Meleties, Panayiotis
    Svoronos, Paris
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [22] The effect of hydrogen peroxide on the biochemical oxygen demand (BOD) values measured during ionizing radiation treatment of wastewater
    Bezsenyi, Aniko
    Sagi, Gyuri
    Mako, Magdolna
    Wojnarovits, Laszlo
    Takacs, Erzsebet
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [23] Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
    Chang, IS
    Jang, JK
    Gil, GC
    Kim, M
    Kim, HJ
    Cho, BW
    Kim, BH
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (06): : 607 - 613
  • [24] Integrated Determination of Chemical Oxygen Demand and Biochemical Oxygen Demand
    Qi, Mengmeng
    Han, Yanhe
    Zhao, Zikun
    Li, Yang
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2021, 30 (02): : 1785 - 1794
  • [25] Development of photocatalytic biosensor for the evaluation of biochemical oxygen demand
    Chee, GJ
    Nomura, Y
    Ikebukuro, K
    Karube, I
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (01): : 67 - 73
  • [26] THE EFFECT OF METALLIC TOXICANTS ON BIOCHEMICAL OXYGEN-DEMAND (BOD) MEASUREMENTS
    ADEMOROTI, CMA
    BIOLOGICAL WASTES, 1988, 24 (04): : 259 - 265
  • [27] Current situation and development of Biochemical Oxygen Demand (BOD) detection standard
    Sun X.
    Huang S.
    Liu Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (22): : 302 - 308
  • [28] Statistical Analysis of Reducing Biochemical Oxygen Demand (BOD) on Industrial Rubber Wastewater using Dielectric Barrier Discharge Plasma
    Syakur, Abdul
    Zaman, Badrus
    Nurmaliakasih, Dias Yunita
    IAES INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS, 2017, 190
  • [29] BIOCHEMICAL OXYGEN DEMAND - DETERMINATION AND VALUE
    TOUZEL, JP
    ANNALES DE TECHNOLOGIE AGRICOLE, 1974, 23 (01): : 97 - 111
  • [30] Determination of biochemical oxygen demand (BOD5) in water samples by potassium iodate-starch spectrophotometry
    Department of Chemical Engineering, Huaihai Institute of Technology, Lianyungang 222005, China
    不详
    不详
    Yejin Fenxi, 2008, 7 (23-27):