Feasibility and diagnostic accuracy of 16-slice multidetector computed tomography coronary angiography in 500 consecutive patients: critical role of heart rate

被引:24
|
作者
Andreini, Daniele [1 ]
Pontone, Gianluca [1 ]
Ballerini, Giovanni [1 ]
Quaglia, Carlo [1 ]
Nobili, Enrica [1 ]
Magini, Alessandra [1 ]
Bertella, Erika [1 ]
Pepi, Mauro [1 ]
机构
[1] Univ Milan, IRCCS, Inst Cardiol, Ctr Cardiol Monzino, I-20138 Milan, Italy
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2007年 / 23卷 / 06期
关键词
beta-blocker therapy; heart rate; misalignment of slices;
D O I
10.1007/s10554-007-9217-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To evaluate the feasibility and diagnostic accuracy of multidetector computed tomography coronary (MDCT) angiography applied to an unselected heart-disease population, to identify all causes of unfeasibility of exams, the distribution of artifacts in every coronary segment and their influence on diagnostic accuracy of examination. Materials and methods We evaluated 500 patients with different indications for invasive coronary angiography. All underwent coronary MDCT and ICA. 215 patients were pre-treated with metoprolol intravenously. In the whole population we studied native coronary arteries and in 141 cases the patency of coronary artery bypass grafts (CABG). The quality of MDCT images was graded as good, sufficient and insufficient. Results We were able to evaluate the patency of all grafts, with the exception of 4 cases. Diagnostic accuracy of CABG evaluation was very high (sensitivity 100%, specificity 98.4%). In native coronary arteries the overall feasibility was 97.9%. The middle left circumflex artery, right coronary artery and posterior descending artery were the segments most often poorly visualized. The first cause of artifacts was misalignment related to high heart rate, followed by premature heart beats and calcified plaque. The population was separated into 3 groups: group 1: heart rate < 55 bpm, group 2: 55-65 bpm, group 3: > 65 bpm. In group 1, misalignment was significantly lower than in groups 2 and 3. On a segment-based analysis, overall feasibility was therefore significantly higher in group 1 vs group 2 and vs group 3. Images of good quality were significantly higher in group 1 (95.4%) than in group 2 (87%) and group 3 (71.8%). The higher image quality in group 1 impacts on the overall diagnostic accuracy of the exam. Indeed overall sensitivity is significantly higher in group 1 (89.5%) than in group 2 (86%) and group 3 (82.8%) and overall specificity is significantly higher in group 1 than in group 3. Conclusion Multidetector computed tomography has a high feasibility and diagnostic accuracy for the evaluation of coronary artery disease in an unselected population. Good patient preparation (optimized beta-blocker therapy, correct breathing instructions) is essential for evaluating native coronary arteries while preparation with a beta-blocker is less relevant in bypass graft patients.
引用
收藏
页码:789 / 801
页数:13
相关论文
共 50 条
  • [21] Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
    Shi-Zheng Zhang
    Xiu-Hua Hu
    Qiao-Wei Zhang
    Wen-Xin Huang
    European Radiology, 2005, 15 : 1105 - 1109
  • [22] Clinical value of 16-slice multidetector computed tomography in symptomatic patients with suspected coronary artery disease
    Turkvattan, A.
    Biyikoglu, S. F.
    Buyukbayraktar, F.
    Oelcer, T.
    ACTA RADIOLOGICA, 2008, 49 (04) : 400 - 408
  • [23] Diagnostic accuracy of 16-slice CT coronary angiography in the evaluation of coronary artery disease
    Soon, K. H.
    Chaitowitz, I.
    Cox, N.
    MacGregor, L.
    Eccleston, D.
    Bell, K. W.
    Kelly, A-M
    Lim, Y. L.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (04): : 365 - 369
  • [24] Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
    Zhang, SZ
    Hu, XH
    Zhang, QW
    Huang, WX
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1105 - 1109
  • [25] Feasibility of assessment of coronary stent patency using 16-slice computed tomography
    Schuijf, JD
    Bax, JJ
    Jukema, JW
    Lamb, HJ
    Warda, HMA
    Vliegen, HW
    de Roos, A
    van der Wall, EE
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (04): : 427 - 430
  • [26] Improvement in the diagnostic accuracy of 64-slice multidetector-row computed tomography compared with 16-slice MD-CT.
    Kamura, A.
    Kawasaki, T.
    Koga, N.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 15D - 15D
  • [27] Ability for visualization, reasons for nonassessable image, and diagnostic accuracy of 16-slice multidetector row helical computed tomography for the assessment of the entire coronary arteries
    Kitagawa, T
    Fujii, T
    Tomohiro, Y
    Maeda, K
    Kobayashi, M
    Kunita, E
    Sekiguchi, Y
    Suzuki, T
    Fujikawa, K
    Yamaguchi, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (09): : 1076 - 1079
  • [28] Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bartorelli, Antonio L.
    Ballerini, Giovanni
    Bertella, Erika
    Segurini, Chiara
    Conte, Edoardo
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Fiorentini, Cesare
    Pepi, Mauro
    AMERICAN HEART JOURNAL, 2014, 168 (03) : 332 - 339
  • [29] Feasibility and diagnostic accuracy of 64-slice multidetector computed tomography coronary angiography in the evaluation of in-stent restenosis: Preliminary results
    Trabattoni, Daniela
    Andreini, Daniele
    Pontone, Gianluca
    Pepi, Mauro
    Ballerini, Giovanni
    Bertella, Erica
    Barlorelli, Antonio L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 135L - 135L
  • [30] The role of 16-slice computed tomography angiography in the diagnosis of coronary artery disease: large sample analysis
    Gaspar, T
    Dvir, D
    Peled, N
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2005, 7 (07): : 424 - 427