Optical Gravimetry mass measurement performance for small body flyby missions

被引:6
|
作者
Bull, Rylie [1 ]
Mitch, Ryan [1 ]
Atchison, Justin [1 ]
McMahon, Jay [2 ]
Rivkin, Andrew [1 ]
Mazarico, Erwan [3 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, 11100 Johns Hopkins Rd, Laurel, MD 20723 USA
[2] Univ Colorado, 429 UCB,AERO 461, Boulder, CO 80309 USA
[3] NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA
关键词
Asteroid gravity science Asteroid flyby; ASTEROID; 21; LUTETIA; GRAVITY-FIELD; ROTATION PERIOD; BULK-DENSITY; SPIN POLE; 433; EROS; SHAPE; ORBIT; MODEL; TRACKING;
D O I
10.1016/j.pss.2021.105289
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
It is challenging or infeasible to precisely measure the mass of small asteroids using the state-of-the-art without a dedicated spacecraft rendezvous mission, which are typically limited to one or a few asteroid targets. Alternatively, spacecraft flyby missions offer the possibility of visiting multiple asteroids but typically lack the sensitivity to measure mass for all but the largest asteroids. In these encounters, Earth-based two-way Doppler is used to measure a change in the spacecraft's velocity imparted by the asteroid. The technique known as Optical Gravimetry (OpGrav) seeks to increase this sensitivity of mass measurements from flyby encounters using optical measurements from the spacecraft to one or more test-masses. In this technique, the spacecraft deploys the testmasses prior to an asteroid flyby and then tracks them before and after the encounter using an on-board telescope. The test-masses can pass much closer to the asteroid than a spacecraft would typically choose such that their trajectories are measurably deflected. This paper provides a quantitative sensitivity analysis of the design parameters most relevant to OpGrav, including asteroid mass, flyby velocity, number of test-masses, test-mass target altitude, test-mass deployment time, and the cadence of optical measurements. Additionally, this paper investigates the effect of practical test-mass deployment errors on the expected mass measurement. Broadly speaking, this analysis shows that OpGrav provides comparable sensitivity to the existing technique at asteroids that are five to ten times smaller in diameter, depending on whether one or three test-masses are deployed. We demonstrate that under realistic mission assumptions, the use of OpGrav would have allowed all previous flyby visits of asteroids, most of which were not able to obtain mass estimates, to achieve better than 25% 1 sigma accuracy in mass measurements, representing a significant improvement on the state of the art.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Concentration measurement with optical fibers for small sample
    Ding, Jiexiong
    Feng, Xiang
    Song, Yi
    Wang, Wei
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2011, 54 (06) : 849 - 856
  • [42] Small optical device for measurement of surface roughness
    Mendeleev, VY
    Skovorod'ko, SN
    Porotov, VN
    Kim, KY
    FIFTH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2001, 4607 : 214 - 216
  • [43] THE MEASUREMENT OF SMALL LINEAR MOTIONS BY OPTICAL METHODS
    HUNT, RWG
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1946, 23 (06): : 119 - 121
  • [44] Concentration measurement with optical fibers for small sample
    Jiexiong Ding
    Xiang Feng
    Yi Song
    Wei Wang
    Instruments and Experimental Techniques, 2011, 54 : 849 - 856
  • [45] Measurement of small dispersion values in optical components
    Peucheret, C
    Liu, F
    Pedersen, RJS
    ELECTRONICS LETTERS, 1999, 35 (05) : 409 - 411
  • [46] Intercomparison study on accurate mass measurement of small molecules in mass spectrometry
    Bristow, AWT
    Webb, KS
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) : 1086 - 1098
  • [47] Intercomparison study on accurate mass measurement of small molecules in mass spectrometry
    Bristow, A.W.T. (tony.bristow@lgc.co.uk), 1600, Elsevier Inc. (14):
  • [48] The concurrent validity of the body center of mass in accelerometric measurement
    Lee, Hyo-Ki
    Cho, Sung-Pil
    You, Joshua H.
    Lee, Kyoung-Joung
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 659 - +
  • [49] BIASES IN THE MEASUREMENT OF BODY MASS INDEX IN OLDER ADULTS
    Conroy-Ferreccio, Gabriel
    NUTRICION HOSPITALARIA, 2017, 34 (01) : 251 - 251
  • [50] Obstetric body mass index measurement and anaesthetic implications
    Sykes, K. E.
    Latif, U.
    Venkata, K. Kada
    ANAESTHESIA, 2013, 68 : 102 - 102