Changes in Macular Thickness After Descemet Stripping Automated Endothelial Keratoplasty

被引:4
|
作者
Mashor, Raneen Shehadeh [1 ]
Nasser, Orwa [1 ,2 ]
Sansanayudh, Wiwan [1 ]
Rootman, David S. [1 ]
Slomovic, Allan R. [1 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Ophthalmol, Toronto, ON M5T 2S8, Canada
[2] Bnai Zion Med Ctr, Technion Israel Inst Technol, Dept Ophthalmol, Haifa, Israel
关键词
OPTICAL COHERENCE TOMOGRAPHY; PENETRATING KERATOPLASTY; RETINAL THICKNESS; EDEMA; EYES;
D O I
10.1016/j.ajo.2014.11.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess changes in macular thickness after Descemet stripping automated endothelial keratoplasty (DSAEK), using optical coherence tomography. DESIGN: Prospective interventional case series. METHODS: SETTING: Institutional. PATIENTS AND INTERVENTION: Thirty-three eyes of 31 patients who had Fuchs dystrophy or pseudophakic bullus keratopathy (PBK) and underwent DSAEK or combined DSAEK with cataract surgery. MAIN OUTCOME. MEASURE: Changes in macular thickness. RESULTS: There were 7 eyes with Fuchs endothelial dystrophy and 9 eyes with pseudophakic bullous keratopathy (PBK) that underwent DSAEK, and 17 eyes with Fuchs endothelial dystrophy and cataract that underwent combined DSAEK with phacoemulsification cataract surgery. For the whole group there was a significant increase of 19.32 mu m in macular thickness at 1 month after surgery (P = .025). At 3 months the increase of 10.33 mu m was not statistically significant (P = .192). For the Fuchs endothelial dystrophy there was a mean increase of 11.83 mu m and a mean decrease of 9 mu m at 1 and 3 months, respectively. For the PBK group there was an increase of 12.37 mu m and 2.428 mu m at 1 month (P = .603) and at 3 months after surgery (P = .883), respectively. These changes were not significant. For the Fuchs endothelial dystrophy and cataract group there was a significant increase of 26.50 mu m at 1 month (P = .012) and 23.15 mu m at 3 months after surgery (P = .038). CONCLUSIONS: Macular thickness significantly increased after DSAEK combined with cataract surgery but did not change significantly when only DSAEK was performed. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:415 / 418
页数:4
相关论文
共 50 条
  • [31] Descemet stripping automated endothelial keratoplasty in a child after failed penetrating keratoplasty
    Kymionis, George D.
    Kankariya, Vardhaman P.
    Diakonis, Vasilios F.
    Karavitaki, Alexandra E.
    Siganos, Charalampos S.
    Pallikaris, Ioannis G.
    JOURNAL OF AAPOS, 2012, 16 (01): : 95 - 96
  • [32] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Busin, Massimo
    Beltz, Jacqueline
    CORNEA, 2011, 30 (09) : 1048 - 1050
  • [33] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Gutfreund, Shay
    Leon, Pia
    Graffi, Shmuel
    Busin, Massimo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 175 : 129 - 136
  • [34] Topographic characteristics after Descemet's membrane endothelial keratoplasty and Descemet's stripping automated endothelial keratoplasty
    Hayashi, Takahiko
    Yamaguchi, Takefumi
    Yuda, Kentaro
    Kato, Naoko
    Satake, Yoshiyuki
    Shimazaki, Jun
    PLOS ONE, 2017, 12 (11):
  • [35] Changes in Intraocular Pressure After Descemet Stripping Automated Endothelial Keratoplasty: A Retrospective Analysis
    Mueller, Luzia
    Kaufmann, Claude
    Bachmann, Lucas M.
    Tarantino-Scherrer, Janine N.
    Thiel, Michael A.
    Bochmann, Frank
    CORNEA, 2015, 34 (03) : 271 - 274
  • [36] Refractive outcomes after descemet stripping automated endothelial keratoplasty surgery associated with graft thickness
    Cheung, Natalie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [37] Recipient corneal thickness and visual outcome after Descemet's stripping automated endothelial keratoplasty
    Ivarsen, Anders
    Hjortdal, Jesper
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 30 - 34
  • [38] Descemet stripping automated endothelial keratoplasty for microcornea
    Hiroshi Toshida
    Toshihiko Ohta
    Akira Murakami
    Akira Kobayashi
    Kazuhisa Sugiyama
    Japanese Journal of Ophthalmology, 2012, 56 : 436 - 440
  • [39] Descemet-stripping automated endothelial keratoplasty
    Gorovoy, Mark S.
    CORNEA, 2006, 25 (08) : 886 - 889
  • [40] Descemet stripping automated endothelial keratoplasty for microcornea
    Toshida, Hiroshi
    Ohta, Toshihiko
    Murakami, Akira
    Kobayashi, Akira
    Sugiyama, Kazuhisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (05) : 436 - 440