Changes in Macular Thickness After Descemet Stripping Automated Endothelial Keratoplasty

被引:4
|
作者
Mashor, Raneen Shehadeh [1 ]
Nasser, Orwa [1 ,2 ]
Sansanayudh, Wiwan [1 ]
Rootman, David S. [1 ]
Slomovic, Allan R. [1 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Dept Ophthalmol, Toronto, ON M5T 2S8, Canada
[2] Bnai Zion Med Ctr, Technion Israel Inst Technol, Dept Ophthalmol, Haifa, Israel
关键词
OPTICAL COHERENCE TOMOGRAPHY; PENETRATING KERATOPLASTY; RETINAL THICKNESS; EDEMA; EYES;
D O I
10.1016/j.ajo.2014.11.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess changes in macular thickness after Descemet stripping automated endothelial keratoplasty (DSAEK), using optical coherence tomography. DESIGN: Prospective interventional case series. METHODS: SETTING: Institutional. PATIENTS AND INTERVENTION: Thirty-three eyes of 31 patients who had Fuchs dystrophy or pseudophakic bullus keratopathy (PBK) and underwent DSAEK or combined DSAEK with cataract surgery. MAIN OUTCOME. MEASURE: Changes in macular thickness. RESULTS: There were 7 eyes with Fuchs endothelial dystrophy and 9 eyes with pseudophakic bullous keratopathy (PBK) that underwent DSAEK, and 17 eyes with Fuchs endothelial dystrophy and cataract that underwent combined DSAEK with phacoemulsification cataract surgery. For the whole group there was a significant increase of 19.32 mu m in macular thickness at 1 month after surgery (P = .025). At 3 months the increase of 10.33 mu m was not statistically significant (P = .192). For the Fuchs endothelial dystrophy there was a mean increase of 11.83 mu m and a mean decrease of 9 mu m at 1 and 3 months, respectively. For the PBK group there was an increase of 12.37 mu m and 2.428 mu m at 1 month (P = .603) and at 3 months after surgery (P = .883), respectively. These changes were not significant. For the Fuchs endothelial dystrophy and cataract group there was a significant increase of 26.50 mu m at 1 month (P = .012) and 23.15 mu m at 3 months after surgery (P = .038). CONCLUSIONS: Macular thickness significantly increased after DSAEK combined with cataract surgery but did not change significantly when only DSAEK was performed. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:415 / 418
页数:4
相关论文
共 50 条
  • [1] Cystoid Macular Edema after Descemet's Stripping Automated Endothelial Keratoplasty
    Kitazawa, Koji
    Kayukawa, Kanae
    Wakimasu, Koichi
    Yokota, Isao
    Inatomi, Tsutomu
    Hieda, Osamu
    Mori, Kazuhiko
    Sotozono, Chie
    Kinoshita, Shigeru
    OPHTHALMOLOGY, 2017, 124 (04) : 572 - 573
  • [2] Changes in Corneal Power After Descemet Stripping Automated Endothelial Keratoplasty
    Clemmensen, Kare
    Ivarsen, Anders
    Hjortdal, Jesper
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (12) : 807 - 812
  • [3] Macular Thickness After Ultrathin Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty Combined With Cataract Surgery: A Randomized Controlled Clinical Trial
    Madsen, Morten Brok Molbech
    Ivarsen, Anders
    Hjortdal, Jesper
    CORNEA, 2023, 42 (12) : 1536 - 1543
  • [4] Incidence of cystoid macular edema after Descemet's stripping automated endothelial keratoplasty
    Pedemonte-Sarrias, Eduard
    Salvador Playa, Toni
    Sassot Cladera, Irene
    Gris, Oscar
    Ribas Martinez, Joan
    Garcia-Arumi, Jose
    Gimenez, Nuria
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (07) : 1081 - 1087
  • [5] Incidence of cystoid macular edema after Descemet's stripping automated endothelial keratoplasty
    Eduard Pedemonte-Sarrias
    Toni Salvador Playà
    Irene Sassot Cladera
    Oscar Gris
    Joan Ribas Martínez
    José García-Arumí
    Núria Giménez
    International Journal of Ophthalmology, 2017, 10 (07) : 1081 - 1087
  • [6] Descemet stripping automated endothelial keratoplasty
    Sharma, Namrata
    Maharana, Prafulla K.
    Singhi, Shipra
    Aron, Neelima
    Patil, Mukesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (03) : 198 - 209
  • [7] Descemet Stripping Automated Endothelial Keratoplasty After Failed Penetrating Keratoplasty
    Jangi, Anisha A.
    Ritterband, David C.
    Wu, Elaine I.
    Mehta, Veeral V.
    Koplin, Richard S.
    Seedor, John A.
    CORNEA, 2012, 31 (10) : 1148 - 1153
  • [8] Corneal biomechanical changes after Descemet stripping automated endothelial keratoplasty, penetrating keratoplasty, and phacoemulsification
    Rahimi, Mahnaz
    Bazaz, Mahmoodreza Panahi
    Sharifipour, Farideh
    Hajizadeh, Maryam
    Cheraghian, Bahman
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 3183 - 3190
  • [9] Descemet Membrane Endothelial Keratoplasty as Treatment for Graft Failure After Descemet Stripping Automated Endothelial Keratoplasty
    Weller, Julia M.
    Tourtas, Theofilos
    Kruse, Friedrich E.
    Schloetzer-Schrehardt, Ursula
    Fuchsluger, Thomas
    Bachmann, Bjoern O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (06) : 1050 - 1057
  • [10] Corneal biomechanical changes after Descemet stripping automated endothelial keratoplasty, penetrating keratoplasty, and phacoemulsification
    Mahnaz Rahimi
    Mahmoodreza Panahi Bazaz
    Farideh Sharifipour
    Maryam Hajizadeh
    Bahman Cheraghian
    International Ophthalmology, 2022, 42 : 3183 - 3190