Punching strength of slabs reinforced for shear with offcuts of rolled steel I-section beams

被引:19
|
作者
Gomes, R
Regan, P
机构
[1] Univ Fed Goiania, Escola Engn Civil, BR-74605220 Goiania, Go, Brazil
[2] Univ Westminster, Sch Architecture & Civil Engn, London NW1 5LS, England
关键词
D O I
10.1680/macr.1999.51.2.121
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Punching shear failure may occur at columns supporting flat slabs or at concentrated loads. The rupture is brittle and may occur clearly below the flexural capacity of the slab. This work aims to analyse the symmetric punching resistance of reinforced concrete flat slabs with shear reinforcement. Twelve 200 mm thick slabs representing regions around columns, loaded at the centre and reacted at the edges, were tested up to failure. Short offcuts of steel I-beams were used as shear reinforcement. The principal variables considered in the tests were the area, number and distribution of the shear steel elements. All the slabs failed by punching, and the failure load of the specimen with the most reinforcement was more than twice that of the slabs without shear reinforcement.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 50 条
  • [41] Size Effect on Punching Strength of Reinforced Concrete Slabs with and without Shear Reinforcement
    Gardner, N. J.
    ACI STRUCTURAL JOURNAL, 2018, 115 (03) : 897 - 899
  • [42] Punching Shear Strength of Reinforced Concrete Slabs without Transverse Reinforcement Discussion
    Muttoni, Aurelio
    Windisch, Andor
    ACI STRUCTURAL JOURNAL, 2009, 106 (03) : 381 - 381
  • [43] Punching Shear in Steel Fibre Reinforced Concrete Slabs without Traditional Reinforcement
    Tan, K. H.
    Venkateshwaran, A.
    FIBRE CONCRETE 2017, 2017, 246
  • [44] A new formula of punching shear strength for fiber reinforced polymer (FRP) or steel reinforced two-way concrete slabs
    Ju, Minkwan
    Ju, Jiann-wen Woody
    Sim, Jongsung
    COMPOSITE STRUCTURES, 2021, 259
  • [45] Mechanical model for the shear-punching strength of steel fiber reinforced concrete slabs under concentric loading
    Mari, Antonio
    Spinella, Nino
    Rodriguez, Ma. Fernanda
    STRUCTURES, 2023, 52 : 854 - 867
  • [46] Postbuckling resistance of high strength steel welded I-section beams based on interactive slenderness
    Xu, Kelong
    Shi, Yongjiu
    THIN-WALLED STRUCTURES, 2021, 159
  • [47] Punching shear strength of glass fiber-reinforced polymer reinforced concrete flat slabs
    Hassan, Mohamed
    Ahmed, Ehab A.
    Benmokrane, Brahim
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2013, 40 (10) : 951 - 960
  • [48] Punching Shear Characterization of Steel Fiber-Reinforced Concrete Flat Slabs
    Mohammed A.H.
    Mubarak H.M.
    Hussein A.K.
    Abulghafour T.Z.
    Nassani D.E.
    HighTech and Innovation Journal, 2022, 3 (04): : 483 - 490
  • [49] Punching shear strength and deformation for FRP-reinforced concrete slabs without shear reinforcements
    Deifalla, A.
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 16
  • [50] Shear Strength of Steel Fiber-Reinforced Concrete Beams and One-Way Slabs
    Alcocer, Sergio M.
    Almasabha, Ghassan
    Carrillo, Julian
    Chao, Shih-Ho
    Lubell, Adam S.
    ACI MATERIALS JOURNAL, 2025, 122 (01) : 103 - 115