200 kHz swept light source equipped with KTN deflector for optical coherence tomography

被引:35
|
作者
Okabe, Y. [1 ]
Sasaki, Y. [1 ]
Ueno, M. [1 ]
Sakamoto, T. [1 ]
Toyoda, S. [1 ]
Yagi, S. [2 ]
Naganuma, K.
Fujiura, K.
Sakai, Y. [1 ]
Kobayashi, J. [1 ]
Omiya, K. [3 ]
Ohmi, M. [4 ]
Haruna, M. [4 ]
机构
[1] NTT Photon Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Adv Technol Corp, Atsugi, Kanagawa 2430124, Japan
[3] Osaka Univ, Grad Sch Engn, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, Japan
[4] Osaka Univ, Grad Sch Med, Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
D O I
10.1049/el.2011.4057
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new light source for swept-source optical coherence tomography (SS-OCT) is presented, namely, an external-cavity LD equipped with a KTN electro-optic deflector. The KTN deflector is unique in being very fast and simultaneously providing an appreciable deflection caused by injected carriers. Being free from mechanical resonance, the 1.3 mu m laser exhibits a scanning range of almost 80 nm up to 200 kHz with a +/- 400 V deflector driving voltage. Preliminary SS-OCT images of a human fingernail and finger skin have been obtained using the swept light source.
引用
收藏
页码:201 / 202
页数:2
相关论文
共 50 条
  • [31] High axial resolution swept source for optical coherence tomography
    Cordes, A. H.
    Xavier, G. B.
    de Faria, G. Vilela
    von der Weid, J. P.
    ELECTRONICS LETTERS, 2010, 46 (01) : 27 - 28
  • [32] Swept source optical coherence tomography artifacts in glaucoma patients
    Lee, S. Y.
    Seo, S. J.
    Lee, Y. H.
    Bae, H. Y.
    Kim, C. Y.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [33] Reproducibility of the measurements taken with swept source optical coherence tomography
    Orduna Hospital, E.
    Vilades Palomar, E.
    Cipres, M.
    Obis, J.
    Rodrigo, M. J.
    Satue, M.
    Garcia-Martin, E.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [34] SPECTRAL SIGNAL PROCESSING IN SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Chang, Shoude
    Mao, Youxin
    Flueraru, Costel
    PHOTONICS NORTH 2010, 2010, 7750
  • [35] Swept source optical coherence tomography angiography in choroidal melanoma
    Pellegrini, Marco
    Corvi, Federico
    Ravera, Vittoria
    Staurenghi, Giovanni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [36] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [37] Swept source cross-polarized optical coherence tomography for any input polarized light
    Sharma, Gargi
    Sharma, Shivani
    Blessing, Katharina
    Hartl, Georg
    Waldner, Maximilian
    Singh, Kanwarpal
    JOURNAL OF OPTICS, 2020, 22 (04)
  • [38] Voltage noise and jitter analysis for swept source optical coherence tomography using KTa1-xNbxO3 deflector
    Sunaga, Hiroshi
    Endo, Kazuma
    Ogawa, Takafumi
    Shinagawa, Mitsuru
    Toyoda, Seiji
    Ueno, Masahiro
    Sasaki, Yuzo
    Chen, Mingchen
    Sakamoto, Tadashi
    MEASUREMENT, 2019, 135 : 753 - 761
  • [39] Comparison of swept source optical coherence tomography and spectral domain optical coherence tomography in polypoidal choroidal vasculopathy
    Ting, Daniel S. W.
    Cheung, Gemmy C. M.
    Lim, Laurence S.
    Yeo, Ian Y. S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 815 - 819
  • [40] Phase Stability Analysis of Swept Light Source with KTa1-xNbxO3 Electro-Optic Deflector toward Doppler Optical Coherence Tomography
    Hasegawa, Shinya
    Shinagawa, Mitsuru
    Toyoda, Seiji
    Ueno, Masahiro
    Sasaki, Yuzo
    Kobayashi, Junya
    2014 IEEE CPMT SYMPOSIUM JAPAN (ICSJ), 2014, : 7 - 10