A study of octupolar excitation for mass-selective centering in Penning traps

被引:8
|
作者
Rosenbusch, M. [1 ]
Boehm, Ch. [2 ]
Borgmann, Ch. [2 ]
Breitenfeldt, M. [3 ]
Herlert, A. [4 ]
Kowalska, M. [4 ]
Kreim, S. [2 ]
Marx, G. [1 ]
Naimi, S. [5 ]
Neidherr, D. [2 ]
Schneider, R. [1 ]
Schweikhard, L. [1 ]
机构
[1] Ernst Moritz Arndt Univ Greifswald, D-17487 Greifswald, Germany
[2] Max Planck Inst Kernphys, D-69117 Heidelberg, Germany
[3] Katholieke Univ Leuven, B-3000 Louvain, Belgium
[4] CERN, CH-1211 Geneva 23, Switzerland
[5] CNRS, IN2P3, CSNSM, F-91405 Orsay, France
关键词
Penning trap; Octupolar excitation; Mass-selective ion centering; ION-CYCLOTRON-RESONANCE; SPECTROMETRY; MOTION; AXIALIZATION; ACCURACY;
D O I
10.1016/j.ijms.2012.01.002
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Octupolar excitation has been investigated with respect to mass-selective ion centering in buffer-gas filled Penning traps for the isolation of an ion species of interest. To this end, off-line test measurements have been performed with the preparation Penning trap of the mass spectrometer ISOLTRAP located at ISOLDE/CERN including a comparison with the conventional quadrupolar excitation. The experimental results are compared to numerical simulations of ions under influence of quadrupolar and octupolar excitation. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 50 条
  • [31] Nanocomposite materials as observed by mass-selective neutron spectroscopy
    Krzystyniak, Matthew
    Romanelli, Giovanni
    Grabowska, Beata
    Fernandez-Alonso, Felix
    JOURNAL OF PHYSICS COMMUNICATIONS, 2024, 8 (02):
  • [32] Mass-selective detection of butylate and its metabolites.
    Blumhorst, MR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 67 - AGRO
  • [33] Mass measurements of few-electron systems in Penning traps
    Carlberg, C
    HYPERFINE INTERACTIONS, 1998, 114 (1-4): : 177 - 195
  • [34] Mass measurements of few-electron systems in Penning traps
    C. Carlberg
    Hyperfine Interactions, 1998, 114 : 177 - 195
  • [35] Diagnosis of a benzene discharge with a mass-selective spectroscopic technique
    Güthe, F
    Ding, HB
    Pino, T
    Maier, JP
    CHEMICAL PHYSICS, 2001, 269 (1-3) : 347 - 355
  • [36] PICOSECOND MASS-SELECTIVE MEASUREMENTS OF MOLECULAR CLUSTER REACTIONS - (CH3I)N A STATE EXCITATION
    SYAGE, JA
    STEADMAN, J
    CHEMICAL PHYSICS LETTERS, 1990, 166 (02) : 159 - 166
  • [37] Octupolar-Excitation Penning-Trap Mass Spectrometry for Q-Value Measurement of Double-Electron Capture in 164Er
    Eliseev, S.
    Roux, C.
    Blaum, K.
    Block, M.
    Droese, C.
    Herfurth, F.
    Kretzschmar, M.
    Krivoruchenko, M. I.
    Ramirez, E. Minaya
    Novikov, Yu N.
    Schweikhard, L.
    Shabaev, V. M.
    Simkovic, F.
    Tupitsyn, I. I.
    Zuber, K.
    Zubova, N. A.
    PHYSICAL REVIEW LETTERS, 2011, 107 (15)
  • [38] A MASS-SELECTIVE NEUTRAL PARTICLE ENERGY ANALYZER WITH BACKGROUND REJECTION
    VANBLOKLAND, AAE
    GRIMBERGEN, TWM
    VANDERVEN, HW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (03): : 1978 - 1987
  • [39] High-accuracy mass spectrometry of fission products with Penning traps
    Kankainen, A.
    Aysto, J.
    Jokinen, A.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2012, 39 (09)
  • [40] Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
    Lohse, S.
    Berrocal, J.
    Boehland, S.
    van de Laar, J.
    Block, M.
    Chenmarev, S.
    Duellmann, Ch. E.
    Nagy, Sz.
    Ramirez, J. G.
    Rodriguez, D.