Biosensor Forster resonance energy transfer detection by the phasor approach to fluorescence lifetime imaging microscopy

被引:68
|
作者
Hinde, Elizabeth [1 ]
Digman, Michelle A. [1 ,2 ]
Welch, Christopher [3 ]
Hahn, Klaus M. [3 ]
Gratton, Enrico [1 ,2 ]
机构
[1] Univ Calif Irvine, Fluorescence Dynam Lab, Dept Biomed Engn, Irvine, CA 92717 USA
[2] Univ Calif Irvine, Dept Dev & Cell Biol, Irvine, CA USA
[3] Univ N Carolina, Dept Pharmacol, Chapel Hill, NC USA
关键词
fluorescence lifetime; phasor analysis; Forster resonance energy transfer; biosensor; VARIABLE-FREQUENCY PHASE; GENERALIZED POLARIZATION; DYNAMICS; RHO; QUANTITATION; ACTIVATION; RESOLUTION; FRET; RAC;
D O I
10.1002/jemt.21054
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
We present here the phasor approach to biosensor Forster resonance energy transfer (FRET) detection by fluorescence lifetime imaging microscopy (FLIM) and show that this method of data representation is robust towards biosensor design as well as the fluorescence artifacts inherent to the cellular environment. We demonstrate this property on a series of dual and single chain biosensors, which report the localization of Rac1 and RhoA activity, whilst performing concomitant ratiometric FRET analysis on the acquired FLIM data by the generalized polarization (GP) approach. We then evaluate and compare the ability of these two methods to quantitatively image biosensor FRET signal as a function of time and space. We find that with lifetime analysis in the phasor plot each molecular species is transformed into a two-dimensional coordinate system where independent mixtures of fluorophores can be distinguished from changes in lifetime due to FRET. This enables the fractional contribution of the free and bound state of a dual chain biosensor or the low and high FRET species of a single chain biosensor to be quantified in each pixel of an image. The physical properties intrinsic to each biosensor design are also accurately characterized by the phasor analysis; thus, this method could be used to inform biosensor optimization at the developmental stage. We believe that as biosensors become more sophisticated and are multiplexed with other fluorescent molecular tools, biosensor FRET detection by the phasor approach to FLIM will not only become imperative to their use but also their advancement. Microsc. Res. Tech., 2011. (c) 2011 Wiley-Liss, Inc.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [21] Recent Advances in Dynamic Monitoring of Drug Release of Nanoparticle Using Forster Resonance Energy Transfer and Fluorescence Lifetime Imaging
    Cheng, Shih-Hsun
    Chen, Nai-Tzu
    Wu, Chia-Yan
    Chung, Chao-Yu
    Hwu, Yeukuang
    Mou, Chung-Yuan
    Yang, Chung-Shi
    Lo, Leu-Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (06) : 798 - 804
  • [22] Fluorescence (Forster) resonance energy transfer imaging of oncogene activity in living cells
    Kiyokawa, E
    Hara, S
    Nakamura, T
    Matsuda, M
    CANCER SCIENCE, 2006, 97 (01): : 8 - 15
  • [23] A genetically encoded Forster resonance energy transfer biosensor for two-photon excitation microscopy
    Kumagai, Yuka
    Kamioka, Yuji
    Yagi, Shunsuke
    Matsuda, Michiyuki
    Kiyokawa, Etsuko
    ANALYTICAL BIOCHEMISTRY, 2011, 413 (02) : 192 - 199
  • [24] Fluorescence lifetime imaging of nuclear DNA: Effect of fluorescence resonance energy transfer
    Murata, S
    Herman, P
    Lin, HJ
    Lakowicz, JR
    CYTOMETRY, 2000, 41 (03): : 178 - 185
  • [25] Investigation of tryptophan-NADH interactions in live human cells using three-photon fluorescence lifetime imaging and Forster resonance energy transfer microscopy
    Jyothikumar, Vinod
    Sun, Yuansheng
    Periasamy, Ammasi
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)
  • [26] Screening for protein-protein interactions using Forster resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM) (vol 6, 28186, 2016)
    Margineanu, Anca
    Chan, Jia Jia
    Kelly, Douglas J.
    Warren, Sean C.
    Flatters, Delphine
    Kumar, Sunil
    Katan, Matilda
    Dunsby, Christopher W.
    French, Paul M. W.
    SCIENTIFIC REPORTS, 2016, 6
  • [27] Concentric Forster Resonance Energy Transfer Imaging
    Wu, Miao
    Algar, W. Russ
    ANALYTICAL CHEMISTRY, 2015, 87 (16) : 8078 - 8083
  • [28] In vivo hexamerization and characterization of the Arabidopsis AAA ATPase CDC48A complex using forster resonance energy transfer-fluorescence lifetime imaging microscopy and fluorescence correlation spectroscopy
    Aker, Jose
    Hesselink, Renske
    Engel, Ruchira
    Karlova, Rumyana
    Borst, Jan Willem
    Visser, Antonie J. W. G.
    de Vries, Sacco C.
    PLANT PHYSIOLOGY, 2007, 145 (02) : 339 - 350
  • [29] Nanosecond fluorescence resonance energy transfer-fluorescence lifetime imaging microscopy to localize the protein interactions in a single living cell
    Elangovan, M
    Day, RN
    Periasamy, A
    JOURNAL OF MICROSCOPY, 2002, 205 : 3 - 14
  • [30] Fluorescence resonance energy transfer determinations using multiphoton fluorescence lifetime imaging microscopy to characterize amyloid-beta plaques
    Bacskai, BJ
    Skoch, J
    Hickey, GA
    Allen, R
    Hyman, BT
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (03) : 368 - 375