Biosensor Forster resonance energy transfer detection by the phasor approach to fluorescence lifetime imaging microscopy

被引:68
|
作者
Hinde, Elizabeth [1 ]
Digman, Michelle A. [1 ,2 ]
Welch, Christopher [3 ]
Hahn, Klaus M. [3 ]
Gratton, Enrico [1 ,2 ]
机构
[1] Univ Calif Irvine, Fluorescence Dynam Lab, Dept Biomed Engn, Irvine, CA 92717 USA
[2] Univ Calif Irvine, Dept Dev & Cell Biol, Irvine, CA USA
[3] Univ N Carolina, Dept Pharmacol, Chapel Hill, NC USA
关键词
fluorescence lifetime; phasor analysis; Forster resonance energy transfer; biosensor; VARIABLE-FREQUENCY PHASE; GENERALIZED POLARIZATION; DYNAMICS; RHO; QUANTITATION; ACTIVATION; RESOLUTION; FRET; RAC;
D O I
10.1002/jemt.21054
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
We present here the phasor approach to biosensor Forster resonance energy transfer (FRET) detection by fluorescence lifetime imaging microscopy (FLIM) and show that this method of data representation is robust towards biosensor design as well as the fluorescence artifacts inherent to the cellular environment. We demonstrate this property on a series of dual and single chain biosensors, which report the localization of Rac1 and RhoA activity, whilst performing concomitant ratiometric FRET analysis on the acquired FLIM data by the generalized polarization (GP) approach. We then evaluate and compare the ability of these two methods to quantitatively image biosensor FRET signal as a function of time and space. We find that with lifetime analysis in the phasor plot each molecular species is transformed into a two-dimensional coordinate system where independent mixtures of fluorophores can be distinguished from changes in lifetime due to FRET. This enables the fractional contribution of the free and bound state of a dual chain biosensor or the low and high FRET species of a single chain biosensor to be quantified in each pixel of an image. The physical properties intrinsic to each biosensor design are also accurately characterized by the phasor analysis; thus, this method could be used to inform biosensor optimization at the developmental stage. We believe that as biosensors become more sophisticated and are multiplexed with other fluorescent molecular tools, biosensor FRET detection by the phasor approach to FLIM will not only become imperative to their use but also their advancement. Microsc. Res. Tech., 2011. (c) 2011 Wiley-Liss, Inc.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [1] Physiological fluorescence lifetime imaging microscopy improves Forster resonance energy transfer detection in living cells
    Chang, Ching-Wei
    Wu, Mei
    Merajver, Sofia D.
    Mycek, Mary-Ann
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)
  • [2] Measuring protein interactions using Forster resonance energy transfer and fluorescence lifetime imaging microscopy
    Day, Richard N.
    METHODS, 2014, 66 (02) : 200 - 207
  • [3] Energy migration alters the fluorescence lifetime of Cerulean: implications for fluorescence lifetime imaging Forster resonance energy transfer measurements
    Koushik, Srinagesh V.
    Vogel, Steven S.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (03)
  • [4] Fluorescence resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM)
    Jovin, TM
    Lidke, DS
    Jares-Erijman, EA
    FROM CELLS TO PROTEINS: IMAGING NATURE ACROSS DIMENSIONS, 2005, 3 : 209 - 216
  • [5] Fluorescence lifetime imaging nanoscopy for measuring Forster resonance energy transfer in cellular nanodomains
    Tardif, Christian
    Nadeau, Gabriel
    Labrecque, Simon
    Cote, Daniel
    Lavoie-Cardinal, Flavie
    De Koninck, Paul
    NEUROPHOTONICS, 2019, 6 (01)
  • [6] Quantifying nuclear wide chromatin compaction by phasor analysis of histone Forster resonance energy transfer (FRET) in frequency domain fluorescence lifetime imaging microscopy (FLIM) data
    Liang, Zhen
    Lou, Jieqiong
    Scipioni, Lorenzo
    Gratton, Enrico
    Hinde, Elizabeth
    DATA IN BRIEF, 2020, 30
  • [7] Screening for protein-protein interactions using Forster resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM)
    Margineanu, Anca
    Chan, Jia Jia
    Kelly, Douglas J.
    Warren, Sean C.
    Flatters, Delphine
    Kumar, Sunil
    Katan, Matilda
    Dunsby, Christopher W.
    French, Paul M. W.
    SCIENTIFIC REPORTS, 2016, 6
  • [8] Adaptive optics for a time-resolved Forster resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM) in vivo
    Coelho, Simao
    Poland, Simon P.
    Devauges, Viviane
    Ameer-Beg, Simon M.
    OPTICS LETTERS, 2020, 45 (10) : 2732 - 2735
  • [9] Global analysis of Forster resonance energy transfer in live cells measured by fluorescence lifetime imaging microscopy exploiting the rise time of acceptor fluorescence
    Laptenok, Sergey P.
    Borst, Jan Willem
    Mullen, Katharine M.
    van Stokkum, Ivo H. M.
    Visser, Antonie J. W. G.
    van Amerongen, Herbert
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (27) : 7593 - 7602
  • [10] Application of fluorescence resonance energy transfer resolved by fluorescence lifetime imaging microscopy for the detection of enterovirus 71 infection in cells
    Ghukasyan, Vladimir
    Hsu, Yueh-Ying
    Kung, Szu-Hao
    Kao, Fu-Jen
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)