Biomechanical effects of screw orientation and plate profile on tibial condylar valgus osteotomy-Finite-element analysis

被引:4
|
作者
Cheng, Chih-Ting [1 ]
Luo, Chu-An [2 ,3 ]
Chen, Yi-Chih [4 ]
机构
[1] Hsinchu MacKay Mem Hosp, Dept Orthoped Surg, Hsinchu, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, Taipei, Taiwan
[3] APlus Biotechnol Co Ltd, Dept Precis Surg Dev, Taipei, Taiwan
[4] Cathay Gen Hosp, Dept Orthoped, Taipei, Taiwan
关键词
knee; TCVO; finite-element; biomechanics; plate; tibial condylar valgus osteotomy; FATIGUE-STRENGTH; BONE; OSTEOARTHRITIS; FRACTURE; MOVEMENT; AGE;
D O I
10.1080/10255842.2020.1772763
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Tibial condylar valgus osteotomy (TCVO) is a type of open wedge high tibial osteotomy for correcting intra-articular deformities of medial knee osteoarthritis. However, there are no implant design and related biomechanical investigations specifically for TCVO. This study aims to investigate the effects of the proximal screw direction and plate profile on the biomechanical behaviors of the TCVO construct. Based on computed tomography images, the tibia model with TCVO was simulated. Four variations (straight and contoured plate profile x convergent and divergent proximal screw direction) with two loading conditions (compressive loads and torsional load) were compared by finite-element method. Fracture risk and construct stability were chosen as the comparison indices. For both loading conditions, the fracture risk of screw, plate and bone was the lowest in straight plate with divergent screw direction (SD), while contoured plate with convergent screw direction (CC) was the highest. Similar results were found in construct stability, SD allowed the smallest micromotions of the L-shaped opening gap, but CC allowed the highest. Divergent screw direction can decrease fracture risk of all components and provide better construct stability, while contoured plate profile seems like to have converse effects. If stability is the major concern, straight plate with divergent screw is recommended for patients with heavy load demands. Contoured plate may be suitable for skinny patients that can reduce the soft tissue irritation.
引用
收藏
页码:906 / 913
页数:8
相关论文
共 50 条
  • [31] Biomechanical Behavior Analysis of Tibia According to Types of Fractures in Opening Wedge High Tibial Osteotomy Based on Finite Element Method
    Sim, On
    Rhee, Seung Joon
    Lee, Chiseung
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2023, 47 (12) : 607 - 614
  • [32] Biomechanical Effects of Novel Osteotomy Approaches on Mandibular Expansion: A Three-Dimensional Finite Element Analysis
    Singh, Pradeep
    Wang, Chao
    Ajmera, Deepal Haresh
    Xiao, Shui Sheng
    Song, Jinlin
    Lin, Zeng
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (08) : 1658.e1 - 1658.e15
  • [33] Finite element analysis of biomechanical effects of residual varus/valgus malunion after femoral fracture on knee joint
    Kai Ding
    Weijie Yang
    Haicheng Wang
    Shi Zhan
    Pan Hu
    Junsheng Bai
    Chuan Ren
    Qi Zhang
    Yanbin Zhu
    Wei Chen
    International Orthopaedics, 2021, 45 : 1827 - 1835
  • [34] Finite element analysis of biomechanical effects of residual varus/valgus malunion after femoral fracture on knee joint
    Ding, Kai
    Yang, Weijie
    Wang, Haicheng
    Zhan, Shi
    Hu, Pan
    Bai, Junsheng
    Ren, Chuan
    Zhang, Qi
    Zhu, Yanbin
    Chen, Wei
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1827 - 1835
  • [35] Biomechanical analysis of distal femoral fracture fixation: dynamic condylar screw versus locked compression plate
    Narsaria, Nidhi
    Singh, Ashutosh K.
    Rastogi, Amit
    Singh, Vakil
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (05) : 770 - 775
  • [36] Biomechanical effect of a lateral hinge fracture for a medial opening wedge high tibial osteotomy: finite element study
    Kang, Kyoung-Tak
    Koh, Yong-Gon
    Lee, Jin-Ah
    Lee, Jae Jung
    Kwon, Sae Kwang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [37] Biomechanical effect of a lateral hinge fracture for a medial opening wedge high tibial osteotomy: finite element study
    Kyoung-Tak Kang
    Yong-Gon Koh
    Jin-Ah Lee
    Jae Jung Lee
    Sae Kwang Kwon
    Journal of Orthopaedic Surgery and Research, 15
  • [38] A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process
    Wagner, A
    Krach, W
    Schicho, K
    Undt, G
    Ploder, O
    Ewers, R
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 94 (06): : 678 - 686
  • [39] Biomechanical optimization of a custom-made positioning and fixing bone plate for Le Fort I osteotomy by finite element analysis
    Huang, Shao-Fu
    Lo, Lun-Jou
    Lin, Chun-Li
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 68 : 49 - 56
  • [40] Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I Osteotomy: a finite element analysis
    Huang, Shao-Fu
    Lo, Lun-Jou
    Lin, Chun-Li
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (16) : 1704 - 1713