Improvement of prostate cancer detection combining a computer-aided diagnostic system with TRUS-MRI targeted biopsy

被引:12
|
作者
Campa, Riccardo [1 ]
Del Monte, Maurizio [1 ]
Barchetti, Giovanni [1 ]
Pecoraro, Martina [1 ]
Salvo, Vincenzo [1 ]
Ceravolo, Isabella [1 ]
Indino, Elena Lucia [1 ]
Ciardi, Antonio [1 ]
Catalano, Carlo [1 ]
Panebianco, Valeria [1 ]
机构
[1] Sapienza Univ Rome, Dept Radiol Sci Oncol & Pathol, Vle Regina Elena 324, I-00161 Rome, Italy
关键词
Prostate cancer; Multiparametric MRI; TRUS; MRI fusion biopsy; Interventional radiology; Prostate biopsy; Computer-aided diagnosis; ULTRASOUND FUSION BIOPSY; GUIDELINES;
D O I
10.1007/s00261-018-1712-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo validate a novel consensus method, called target-in-target, combining human analysis of mpMRI with automated CAD system analysis, with the aim to increasing the prostate cancer detection rate of targeted biopsies.MethodsA cohort of 420 patients was enrolled and 253 patients were rolled out, due to exclusion criteria. 167 patients, underwent diagnostic 3T MpMRI. Two expert radiologists evaluated the exams adopting PI-RADSv2 and CAD system. When a CAD target overlapped with a radiologic one, we performed the biopsy in the overlapping area which we defined as target-in-target. Targeted TRUS-MRI fusion biopsy was performed in 63 patients with a total of 212 targets. The MRI data of all targets were quantitatively analyzed, and diagnostic findings were compared to pathologist's biopsy reports.ResultsCAD system diagnostic performance exhibited sensitivity and specificity scores of 55.2% and 74.1% [AUC=0.63 (0.54 divided by 0.71)] , respectively. Human readers achieved an AUC value, in ROC analysis, of 0.71 (0.63 divided by 0.79). The target-in-target method provided a detection rate per targeted biopsy core of 81.8 % vs. a detection rate per targeted biopsy core of 68.6 % for pure PI-RADS based on target definitions. The higher per-core detection rate of the target-in-target approach was achieved irrespective of the presence of technical flaws and artifacts.ConclusionsA novel consensus method combining human reader evaluation with automated CAD system analysis of mpMRI to define prostate biopsy targets was shown to improve the detection rate per biopsy core of TRUS-MRI fusion biopsies. Results suggest that the combination of CAD system analysis and human reader evaluation is a winning strategy to improve targeted biopsy efficiency.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 50 条
  • [41] Computer-aided diagnosis of prostate cancer in the peripheral zone using multiparametric MRI
    Niaf, Emilie
    Rouviere, Olivier
    Mege-Lechevallier, Florence
    Bratan, Flavie
    Lartizien, Carole
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3833 - 3851
  • [42] COMPARISON OF TRUS-TARGETED VS. MRI-TARGETED VS. SYSTEMATIC PROSTATE BIOPSY IN DETECTING PROSTATE CANCER
    Herlemann, Annika
    Cooperberg, Matthew R.
    Overland, Maya R.
    Cowan, Janet E.
    Washington, Samuel L., III
    Carroll, Peter R.
    Nguyen, Hao G.
    Shinohara, Katsuto
    JOURNAL OF UROLOGY, 2019, 201 (04): : E426 - E427
  • [43] Realtime TRUS/MRI Fusion Targeted-Biopsy for Prostate Cancer: A Clinical Demonstration of Increased Positive Biopsy Rates
    Kadoury, Samuel
    Yan, Pingkun
    Xu, Sheng
    Glossop, Neil
    Choyke, Peter
    Turkbey, Bans
    Pinto, Peter
    Wood, Bradford J.
    Kruecker, Jochen
    PROSTATE CANCER IMAGING: COMPUTER-AIDED DIAGNOSIS, PROGNOSIS, AND INTERVENTION, 2010, 6367 : 52 - +
  • [44] Computer-aided diagnostic detection system of venous beading in retinal images
    Yang, CW
    Ma, DJ
    Chao, SC
    Wang, CM
    Wen, CH
    Lo, CS
    Chung, PC
    Chang, CI
    OPTICAL ENGINEERING, 2000, 39 (05) : 1293 - 1303
  • [45] Computer-aided detection (CAD) of breast-cancer diagnostic performance of a further improved system
    Hochmuth, A
    Fleck, M
    Minkus, C
    Boehm, T
    Marx, C
    Kaiser, WA
    10TH INTERNATIONAL CONGRESS ON SENOLOGY - BREAST DISEASES OF THE SENOLOGIC INTERNATIONAL SOCIETY, 1998, : 415 - 418
  • [46] PROMETEO: A CNN-Based Computer-Aided Diagnosis System for WSI Prostate Cancer Detection
    Duran-Lopez, Lourdes
    Dominguez-Morales, Juan P.
    Felix Conde-Martin, Antonio
    Vicente-Diaz, Saturnino
    Linares-Barranco, Alejandro
    IEEE ACCESS, 2020, 8 : 128613 - 128628
  • [47] Computer-aided detection (CAD) of breast-cancer - Diagnostic performance of a further improved system
    Hochmuth, A
    Fleck, M
    Minkus, C
    Boehm, T
    Marx, C
    Kaiser, WA
    DIGITAL MAMMOGRAPHY, 1998, 13 : 493 - 494
  • [48] THE FEASIBILITY OF A NOVEL MRI-TRUS NAVIGATION SYSTEM FOR TARGETED FUSION BIOPSY OF EARLY STAGE PROSTATE CANCER: THE PRELIMINARY EXPERIENCE
    Mouraviev, Vladimir
    Pugnale, Michael
    Kalyanaraman, Balaji
    Verma, Sadhna
    Nistor, Vasile
    Zhai, Qihui 'Jim'
    Gaitonde, Krishnanath
    Patil, Nilesh
    Bracken, Bruce
    Donovan, James
    JOURNAL OF ENDOUROLOGY, 2012, 26 : A42 - A42
  • [49] Intelligent computer-aided diagnosis system for breast MRI combining kinetic and morphological aspects
    Wismueller, Axel
    Meyer-Baese, Anke
    Lange, Oliver
    INTELLIGENT COMPUTING: THEORY AND APPLICATIONS VI, 2008, 6961
  • [50] Evaluating Prostate Cancer: The Diagnostic Impact of MRI and Its Relationship With Transrectal Ultrasound (TRUS)-Guided Biopsy
    Ahmed, Mohammed Musheer
    Kaushik, J.
    Yogesh, S.
    Subburam, Sairam
    Raja, Dinesh
    Thinakaran, Siddarth
    Raj, M. R. Madan Karthik
    Lohakare, Tejaswee
    Prashanth, A.
    Mittal, Gaurav
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)