A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements

被引:51
|
作者
Benni, Paul B. [1 ]
MacLeod, David [2 ]
Ikeda, Keita [2 ,3 ]
Lin, Hung-Mo [4 ]
机构
[1] CAS Med Syst CASMED Inc, Branford, CT 06405 USA
[2] Duke Univ, Med Ctr, Dept Anesthesiol, Human Pharmacol & Physiol Lab, Durham, NC 27710 USA
[3] Univ Virginia, Dept Anesthesiol, Charlottesville, VA USA
[4] Icahn Sch Med Mt Sinai, Dept Populat Hlth Sci & Policy, New York, NY 10029 USA
基金
美国国家卫生研究院;
关键词
Tissue oximetry; Cerebral oximetry; Near Infrared Spectroscopy; NIRS; Tissue oxygen; Saturation; FDA; CONCORDANCE CORRELATION-COEFFICIENT; POSITRON-EMISSION-TOMOGRAPHY; CONGENITAL HEART-DISEASE; INTERNAL JUGULAR VEINS; TIDAL CARBON-DIOXIDE; RISK CARDIAC-SURGERY; BLOOD-VOLUME; HEALTHY-VOLUNTEERS; IN-VIVO; OXIDATIVE-METABOLISM;
D O I
10.1007/s10877-017-0015-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We describe the validation methodology for the NIRS based FORE-SIGHT ELITEA (R) (CAS Medical Systems, Inc., Branford, CT, USA) tissue oximeter for cerebral and somatic tissue oxygen saturation (StO(2)) measurements for adult subjects submitted to the United States Food and Drug Administration (FDA) to obtain clearance for clinical use. This validation methodology evolved from a history of NIRS validations in the literature and FDA recommended use of Deming regression and bootstrapping statistical validation methods. For cerebral validation, forehead cerebral StO(2) measurements were compared to a weighted 70:30 reference (REF CXB) of co-oximeter internal jugular venous and arterial blood saturation of healthy adult subjects during a controlled hypoxia sequence, with a sensor placed on the forehead. For somatic validation, somatic StO(2) measurements were compared to a weighted 70:30 reference (REF CXS) of co-oximetry central venous and arterial saturation values following a similar protocol, with sensors place on the flank, quadriceps muscle, and calf muscle. With informed consent, 25 subjects successfully completed the cerebral validation study. The bias and precision (1 SD) of cerebral StO(2) compared to REF CXB was -0.14 +/- 3.07%. With informed consent, 24 subjects successfully completed the somatic validation study. The bias and precision of somatic StO(2) compared to REF CXS was 0.04 +/- 4.22% from the average of flank, quadriceps, and calf StO(2) measurements to best represent the global whole body REF CXS. The NIRS validation methods presented potentially provide a reliable means to test NIRS monitors and qualify them for clinical use.
引用
收藏
页码:269 / 284
页数:16
相关论文
共 50 条
  • [1] A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements
    Paul B. Benni
    David MacLeod
    Keita Ikeda
    Hung-Mo Lin
    Journal of Clinical Monitoring and Computing, 2018, 32 : 269 - 284
  • [2] Reproducibility of cerebral tissue oxygen saturation measurements by near-infrared spectroscopy in newborn infants
    Jenny, Carmen
    Biallas, Martin
    Trajkovic, Ivo
    Fauchere, Jean-Claude
    Bucher, Hans Ulrich
    Wolf, Martin
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)
  • [3] Comparison between tissue oxygen saturation as determined by near-infrared spectroscopy and direct measurements of subcutaneous tissue oxygen
    Akca, O
    Doufas, AG
    Lin, CM
    Sessler, DI
    ANESTHESIOLOGY, 2002, 97 (03) : B15 - B15
  • [4] REPRODUCIBILITY OF CEREBRAL TISSUE OXYGEN SATURATION MEASUREMENTS BY NEAR INFRARED SPECTROSCOPY IN NEWBORN INFANTS
    Jenny, C.
    Biallas, M.
    Trajkovic, I.
    Wolf, M.
    PEDIATRIC RESEARCH, 2010, 68 : 165 - 165
  • [5] 321 Reproducibility of Cerebral Tissue Oxygen Saturation Measurements by Near Infrared Spectroscopy in Newborn Infants
    C Jenny
    M Biallas
    I Trajkovic
    M Wolf
    Pediatric Research, 2010, 68 : 165 - 165
  • [6] Physiologic Determinants of Near-Infrared Spectroscopy-Derived Cerebral and Tissue Oxygen Saturation Measurements in Critically Ill Patients
    Cody, Neil
    Bradbury, Ian
    McMullan, Ross R.
    Quinn, Gerard
    O'Neill, Aisling
    Ward, Kathryn
    McCann, Justine
    McAuley, Daniel F.
    Silversides, Jonathan A.
    CRITICAL CARE EXPLORATIONS, 2024, 6 (05) : E1094
  • [7] Cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation
    Mellor A.
    Critical Care, 1 (1):
  • [8] NEAR-INFRARED SPECTROSCOPY AND CHANGES IN TISSUE OXYGEN-SATURATION DURING EXERCISE
    BELARDINELLI, R
    BARSTOW, TJ
    WASSERMAN, K
    CIRCULATION, 1992, 86 (04) : 98 - 98
  • [9] Near-Infrared Spectroscopy Assessment of Tissue Saturation of Oxygen in Torsed and Healthy Testes
    Schoenfeld, E. M.
    Coute, R.
    Blank, F. S.
    Capraro, G.
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (04) : S59 - S60
  • [10] Near-infrared spectroscopy monitoring tissue oxygen saturation after cardiac surgery
    R Kopp
    S Rex
    K Dommann
    G Schälte
    G Dohmen
    G Marx
    R Rossaint
    Critical Care, 13 (Suppl 1):