A Preliminary Study on Fast Calibration Method for Magnetic Positioning Sensor Array

被引:0
|
作者
Wu, Xiaoyang [1 ]
Song, Shuang [1 ]
Wang, Jiaole [1 ]
机构
[1] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen, Peoples R China
来源
关键词
magnetic localization; sensor calibration; magnetic sensor array;
D O I
10.1109/SENSORS47087.2021.9639245
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic positioning method can be well used for tracking of intra-body objects, such as wireless capsule robot. Before the magnetic sensor array can be used to locate the target, it is necessary to calibrate each sensor to ensure tracking accuracy. Existing calibration methods generally require a large number of samples with prior known pose information of the magnetic target, and then the calibrated coefficients can be obtained by optimization method. Aiming to simplify the calibration process, we propose a fast calibration method in which position and direction of magnetic target are not required during the calibration by introducing a novel calibration tool and corresponding algorithm. As a result, the calibration process can be simple and no advanced pose information is needed. Experimental results verified the proposed method.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A fast method for gain-phase error calibration in conformal array
    Zhang, X.-J. (xjzhang7@163.com), 1600, Science Press (36):
  • [22] Study on the method of measuring direction and positioning with the sparse linear array sensor on the Partial discharge (PD) source
    Liu, Tong
    Xu, Xiaolong
    Du, Hao
    Proceedings of the 2016 4th International Conference on Machinery, Materials and Information Technology Applications, 2016, 71 : 358 - 360
  • [23] A two step iterative calibration method for permanent magnet positioning system sensor
    Kong, Ping
    Pan, Yu
    Chen, Quan
    Chi, Zhipeng
    Li, Ran
    Zhongguo Guanxing Jishu Xuebao/Journal of Chinese Inertial Technology, 2024, 32 (08): : 833 - 840
  • [24] The impact of sensor positioning on the array manifold
    Sleiman, A
    Manikas, A
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2003, 51 (09) : 2227 - 2237
  • [25] A New Measurement and Calibration Method of the Synchronization Sampling Error of Sensor Array
    Jiang, Jiajia
    Duan, Fajie
    Chen, Jin
    Hua, Xiangning
    Li, Yanchao
    2013 10TH IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA), 2013, : 794 - 798
  • [26] Study on fast calibration method of photoelectric sighting
    Zhang Zhuo
    Wang Shaohua
    Wen Zhijie
    Fan Dapeng
    SEVENTH ASIA PACIFIC CONFERENCE ON OPTICS MANUFACTURE (APCOM 2021), 2022, 12166
  • [27] Reference magnetic actuator for self calibration of a very small Hall sensor array
    Demierre, M
    Pesenti, S
    Frounchi, J
    Besse, PA
    Popovic, RS
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 136 - 139
  • [28] Study on the time calibration method of the YangBaJing Hybrid Array
    Zhao, Shaozhang
    Chen, Tianlu
    Gao, Qi
    Feng, Youliang
    ASTROPHYSICS AND SPACE SCIENCE, 2024, 369 (04)
  • [29] A Map-Aided Fast Initialization Method for the Magnetic Positioning of Vehicles
    Lu, Yi
    Wei, Dongyan
    Li, Wen
    Ji, Xinchun
    Yuan, Hong
    ELECTRONICS, 2024, 13 (07)
  • [30] Fast and Accurate Near-Field Calibration Method for Phased Array Antennas
    Jin, Xin
    Wang, Shuai
    Lin, Yujie
    Bu, Xiangyuan
    An, Jianping
    2018 10TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS AND SIGNAL PROCESSING (WCSP), 2018,