Real-time myocardial contrast echocardiography for pharmacologic stress testing: Is quantitative estimation of myocardial blood flow reserve necessary?

被引:27
|
作者
Korosoglou, G
da Silva, KGC
Labadze, N
Dubart, AE
Hansen, A
Rosenberg, M
Zehelein, J
Kuecherer, H
机构
[1] Heidelberg Univ, Dept Cardiol, D-69115 Heidelberg, Germany
[2] Univ Lille, Clin Invest Ctr, Lille, France
关键词
D O I
10.1016/j.echo.2003.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Little is known about the diagnostic accuracy of quantitative real-time myocardial contrast echocardiography (MCE) as an adjunct to stress testing. This study was performed to evaluate the agreement between MCE and technetium 99m-sestamibi single photon emission computed tomography (SPECT) for detection of perfusion defects and to investigate whether quantitative assessment of myocardial perfusion can increase the diagnostic value of MCE. Methods. MCE was performed at rest and during peak adenosine stress in 50 unselected patients undergoing SPECT imaging. Concordance between the 2 methods was assessed using K statistics. MCE images were analyzed quantitatively, measuring peak intensity (A) and maximal rise of signal intensity (beta). Myocardial blood flow reserve was estimated by calculating the ratios of A(adenosine)/A(baseline) (A reserve), beta(adenosine)/beta(baseline) (beta reserve), and A x beta(adenosine)/A x beta(baseline) (A X beta reserve). Results: Visual analysis of MCE agreed well with SPECT (K = 0.67) with sensitivity of 64%, specificity of 97%, and overall accuracy of 87%. Quantitative analysis showed that peak signal intensity A significantly increased under adenosine stress in SPECT-normal segments (2.6 +/- 1.9 vs 3.0 +/- 1.6 dB, P < .0001), tendencially decreased in reversible (3.0 +/- 2.0 vs 2.4 +/- 1.2 dB, P = .07) and remained unchanged in fixed (0.9 +/- 0.9 vs 0.8 +/- 0.9 dB) defects. P increased markedly under adenosine in normal segments (0.4 +/- 0.4 vs 1.4 +/- 1.3, beta < .0001) but not in segments with reversible or fixed defects. Receiver operating characteristic showed that beta reserve and A x beta reserve, but not A reserve, are sensitive parameters for detecting perfusion defects with areas under the curve of 0.84, 0.85, and 0.61, respectively. Cut-off values of 1.9 and 2.3, respectively, for beta and A x beta reserve yielded sensitivity rates of 79% and 80%, specificity rates of 75% and 78%, and overall accuracy rates of 76% and 79%, respectively. Conclusion: Quantitative estimation of myocardial blood flow reserve by MCE parameters corresponds to the evaluation of myocardial perfusion by nuclear imaging and can increase the sensitivity but not the overall accuracy of contrast echocardiography.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Regional myocardial blood flow reserve in normal humans using parametric analysis of real-time myocardial contrast echocardiography
    Li, P
    Murthy, TH
    Locricchio, E
    Ismail, D
    Rajput, FS
    Baisch, C
    Vannan, MA
    CIRCULATION, 2000, 102 (18) : 472 - 472
  • [2] Novel quantification method of myocardial blood flow in real-time myocardial contrast echocardiography
    Otani, K
    Masuda, K
    Asanuma, T
    Ishikura, F
    Beppu, S
    CIRCULATION, 2005, 112 (17) : U781 - U781
  • [3] Quantification of transmural gradient of myocardial blood flow with real-time myocardial contrast echocardiography and dipyridamole stress test
    Yao, Gui Hua
    Zhang, Cheng
    Zhang, Peng Fei
    Zhang, Mei
    Zhao, Yu Xia
    Ding, Shi Fang
    Zhong, Ming
    Li, Xiao Nan
    Chen, Wen Qiang
    Zhang, Yun
    CIRCULATION, 2006, 114 (18) : 481 - 481
  • [4] How valuable is real-time myocardial contrast echocardiography for pharmacological stress testing?
    da Silva, KGC
    Dubart, AE
    Ferrari, N
    Korosoglou, G
    Rosenberg, M
    Zehelein, J
    Kuecherer, HF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 432A - 432A
  • [5] Quantification of transmural gradient of blood flow in myocardial ischemia with real-time myocardial contrast echocardiography and dipyridamole stress test
    Yao, Gui-Hua
    Zhang, Cheng
    Sun, Feng-Rong
    Zhang, Mei
    Zhao, Yu-Xia
    Zhang, Peng-Fei
    Zhong, Lin
    Ding, Shi-Fang
    Chen, Wen-Qiang
    Li, Xiao-Nan
    Zhang, Yun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01): : 22 - 30
  • [6] A Workstation for the Quantitative Analysis of Real-time Myocardial Contrast Echocardiography
    Sun, Feng-rong
    Zhang, Ming-qiang
    Jia, Xiao-bo
    Yao, Gui-hua
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 122 - +
  • [7] Quantitative real-time myocardial contrast echocardiography demonstrates that myocardial blood volume increases during dobutamine stress in normal humans
    Kuersten, B
    Li, P
    Murthy, TH
    Paz, F
    Locricchio, E
    Vannan, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 440A - 440A
  • [8] Resting myocardial blood flow not myocardial flow reserve predicts hibernating myocardium: a quantitative myocardial contrast echocardiography study
    Hickman, M.
    Burden, L.
    Senior, R.
    EUROPEAN HEART JOURNAL, 2007, 28 : 526 - 526
  • [9] Resting myocardial blood flow not myocardial flow reserve predicts hibernating myocardium: A quantitative myocardial contrast echocardiography study
    Hickman, Michael
    Burden, Leah
    Senior, Roxy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 131A - 131A
  • [10] Resting myocardial blood flow not myocardial flow reserve predicts hibernating myocardium: A quantitative myocardial contrast echocardiography study
    Hickman, M.
    Burden, L.
    Senior, R.
    HEART, 2007, 93 : A52 - A52