Ultrasound Guided Out-of-Plane Versus In-Plane Transpectoral Left Axillary Vein Cannulation

被引:17
|
作者
Maddali, Madan Mohan [1 ]
Arora, Nishant Ram [1 ]
Chatterjee, Nilay [2 ]
机构
[1] Royal Hosp, Natl Heart Ctr, Dept Cardiac Anesthesia, Muscat, Oman
[2] Khoula Hosp, Dept Anesthesia, Muscat, Oman
关键词
axillary vein/ultrasonography; catheterization; central venous/methods; clinical competence; axillary vein access; ultrasound imaging plane evaluation; RANDOMIZED CONTROLLED-TRIAL; INTERNAL JUGULAR-VEIN; VENOUS CATHETERIZATION; SUBCLAVIAN-VEIN; COMPLICATIONS; RISK; ARM;
D O I
10.1053/j.jvca.2017.02.011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The primary objective was to compare the frequency of first-attempt successful axillary vein cannulation by the Seldinger technique using out-of-plane ultrasound guidance versus in-plane imaging. Between the two ultrasound imaging planes, this study also compared the number of attempts that were necessary for the cannulation of the left axillary vein along with the number of needle redirections that had to be done for final cannulation of the vein. Incidence of complications and the number of times the procedure was abandoned also were compared between the two imaging planes. Design: Prospective, randomized, interventional study. Setting: Tertiary care cardiac center. Participants: Cardiac surgical patients. Interventions: Left axillary vein cannulation under ultrasound guidance by Seldinger technique. Measurements and Main Results: The left axillary vein was accessed under ultrasound guidance in 86 consecutive adult cardiac surgical patients. They were randomized to out-of-plane (Group I, n = 43) and in-plane (Group II, n = 43) groups. In group I, the number of first attempt cannulations was very high (p < 0.01). The number of attempts to access the vein was significantly lower in this group (p < 0.05). The duration for completion of the procedure was also less in group I with out-of-plane ultrasound guidance (p < 0.01). The number of needle redirections and the incidence of complications (arterial puncture, pneumothorax hematoma formation) were similar between the groups. There was no difference in the number of times the procedure was abandoned between the two groups. With an assumption that the first 10 patients in each group would suffice for overcoming the learning curve, the above aspects were analyzed further in each group. The first-attempt cannulation success continued to be significantly higher in the out-of-plane group. Conclusions: Out-of-plane ultrasound imaging during axillary vein cannulation increased the chance of first-attempt successful cannulation. Axillary vein cannulation under out-of-plane ultrasound imaging also appeared to be quicker and was preferable in terms of the fewer number of attempts that were necessary for a successful vein cannulation. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1707 / 1712
页数:6
相关论文
共 50 条
  • [31] Role of in-plane and out-of-plane dilution in CeFeAsO: Charge doping versus disorder
    Prando, G.
    Vakaliuk, O.
    Sanna, S.
    Lamura, G.
    Shiroka, T.
    Bonfa, P.
    Carretta, P.
    De Renzi, R.
    Klauss, H. -H.
    Blum, C. G. F.
    Wurmehl, S.
    Hess, C.
    Buechner, B.
    PHYSICAL REVIEW B, 2013, 87 (17):
  • [32] The ratio of out-of-plane to in-plane stresses for plane strain problems
    Changlu Tian
    Meccanica, 2009, 44 : 105 - 107
  • [33] Accurate energetics for in-plane versus out-of-plane phenol, thiophenol, anisole, and thioanisole
    Doerksen, RJ
    Chen, B
    DeGrado, WF
    Klein, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U787 - U787
  • [34] Ultrasound-guided short-axis in-plane method for safe axillary vein catheterization
    Tang, Jia-Xi
    Wang, Ling
    Xu, Fang
    Nian, Wei-Qi
    Liu, Hong-Liang
    JOURNAL OF CLINICAL ANESTHESIA, 2022, 82
  • [35] Comparison between classic short-axis out-of-plane approach and novel medial-oblique in-plane approach to ultrasound guided right internal jugular vein cannulation: A randomized controlled trial
    Baidya, D. K.
    Arora, M. K.
    Ray, B. R.
    Mohan, V. K.
    Anand, R. K.
    Khanna, P.
    Maitra, S.
    ACTA ANAESTHESIOLOGICA BELGICA, 2018, 69 (02) : 107 - 112
  • [36] In-Plane and Out-of-Plane Elastodynamics of Thin Rings and Seals
    Turnbull, R.
    Rahmani, R.
    Rahnejat, H.
    JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2019, 14 (08):
  • [37] A new method for facilitating ultrasound-guided in-plane cannulation of the subclavian vein: a randomized clinical trial
    Mao, Qingxiang
    He, Haitao
    Lu, Yuangang
    Hu, Yi
    Wang, Zhen
    Gan, Maoxiang
    Chen, Liyong
    Yan, Hong
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [38] In-plane and out-of-plane buckling of arches made of FGM
    Shafiee, H.
    Naei, M. H.
    Eslami, M. R.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2006, 48 (08) : 907 - 915
  • [39] In-plane and out-of-plane motions of the human tympanic membrane
    Khaleghi, Morteza
    Cheng, Jeffrey Tao
    Furlong, Cosme
    Rosowski, John J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 139 (01): : 104 - 117
  • [40] Effect of out-of-plane material behavior on in-plane modeling
    Manjula, S
    Sitaraman, SK
    ITHERM '98: SIXTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 1998, : 256 - 262