摘要
With the newest medical researches and studies increase equipment's rate of health centers. By contrast to it, any parts of medicine in SR and abroad don't utilize all actual knowledge's and possibilities. One of this is the measurement of intra-abdominal pressure in critical ill patients. From the results of analysis the most often intra-abdominal pressure measurement is via bladder. This is not invasive method with high significant weight. The measurement techniques what are in present time usually used does not meet criteria for modern diagnostic methods. This paper describes the verification of measuring system for intra - abdominal pressure measurement. The measuring system is the basic part of proposal device for automated measurement of intra - abdominal pressure.
引用
收藏
页码:297 / +
页数:2
相关论文
共 50 条
  • [21] Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure
    Federico Garcia, Alberto
    Ignacio Sanchez, Alvaro
    Jose Gutierrez, Alvaro
    Gabriel Bayona, Juan
    Paula Naranjo, Maria
    Lago, Sebastian
    Carlos Puyana, Juan
    JOURNAL OF SURGICAL RESEARCH, 2018, 227 : 112 - 118
  • [22] Noninvasive Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension
    van Ramshorst, Gabrielle H.
    Salih, Mahdi
    Hop, Wim C. J.
    van Waes, Oscar J. F.
    Kleinrensink, Gert-Jan
    Goossens, Richard H. M.
    Lange, Johan F.
    JOURNAL OF SURGICAL RESEARCH, 2011, 171 (01) : 240 - 244
  • [23] THE MEASUREMENT OF INTRA-ABDOMINAL PRESSURE AS A CRITERION FOR ABDOMINAL RE-EXPLORATION
    KRON, IL
    HARMAN, PK
    NOLAN, SP
    ANNALS OF SURGERY, 1984, 199 (01) : 28 - 30
  • [25] Direct measurement of intra-abdominal pressure with a solid microtranducer
    Pracca F.F.
    Biestro A.A.
    Moraes L.
    Puppo C.B.
    Calvo S.M.
    Gorrasi J.
    Cancela M.
    Journal of Clinical Monitoring and Computing, 2007, 21 (3) : 167 - 170
  • [26] New technique of direct intra-abdominal pressure measurement
    Risin, Elena
    Kessel, Boris
    Lieberman, Noah
    Schmilovich, Michael
    Ashkenazi, Itamar
    Alfici, Ricardo
    ASIAN JOURNAL OF SURGERY, 2006, 29 (04) : 247 - 250
  • [27] Abdominocentesis and intra-abdominal pressure measurement in small animals
    Munguia, George G.
    Thomovsky, Elizabeth
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (09): : 1 - 1
  • [28] A user's guide to intra-abdominal pressure measurement
    Sugrue, Michael
    De Waele, Jan J.
    De Keulenaer, Bart L.
    Roberts, Derek J.
    Malbrain, Manu L. N. G.
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2015, 47 (03) : 241 - 251
  • [30] Intra-abdominal pressure measurement using a bladder catheter
    Rozov, R
    Pottecher, T
    Launoy, A
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2004, 23 (04): : 433 - 434