Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Survivorship, Wear Analysis, and Clinical Outcomes Between 15 and 20 Years

被引:14
|
作者
Stambough, Jeffrey B. [1 ]
Rames, Richard D. [2 ]
Pashos, Gail E. [2 ]
Maloney, William J. [3 ]
Martell, John M. [4 ]
Clohisy, John C. [2 ]
机构
[1] Univ Arkansas Med Sci, Dept Orthopaed Surg, 4301 West Markham St,Slot 531, Little Rock, AR 72205 USA
[2] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO USA
[3] Stanford Univ, Sch Med, Dept Orthoped Surg, Redwood City, CA USA
[4] Univ Chicago Med & Biol Sci, Dept Orthopaed Surg & Rehabil Med, Orthopaed Biomed Inst, Chicago, IL USA
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 12期
关键词
conventional polyethylene; wear; osteolysis; survivorship analysis; Martell method; total hip arthroplasty outcomes; CROSS-LINKED POLYETHYLENE; RANDOMIZED CONTROLLED-TRIAL; FOLLOW-UP; REVISION RATES; OSTEOLYSIS; THA; ASSOCIATION; REPLACEMENT; VALIDATION; AGE;
D O I
10.1016/j.arth.2018.08.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip arthroplasty (THA) remains a successful procedure for most patients. However, there is a paucity of information regarding the long-term performance of conventional polyethylene (CPE) bearings in young patients undergoing THA. Methods: After accounting for incomplete follow-up of a prospective cohort of 123 THAs in patients <= 50 years, we performed a retrospective review of 101 hips in 84 patients (82.1%) with an average 17.1-year follow-up (14.7-19.6 years). Outcomes of interest included linear and volumetric wear, clinical outcome scores, implant survivorship, and patient mortality. Wear rates were calculated using Martell Software. Results: Wear analysis revealed median linear and volumetric wear rates of 0.106 mm/y (confidence interval, 0.079-0.133) and 43.58 mm(3)/y (confidence interval, 33.4-53.75). The modified Harris hip scores improved by 36 points while University of California, Los Angeles activity scores improved by 2.0 points at 15-year follow-up (P < .0001). Twenty-two hips (21.8%) were revised, 13 of which (12.8%) were for wear-related causes at an average of 14.9 years (range, 9.2-21 years) from index arthroplasty. There was significantly higher mortality in patients with a preoperative diagnosis of inflammatory avascular necrosis (P = .015). Conclusion: Because CPE was commonly used in THA over the last 25 years, it is important to understand its implications on the growing revision burden. Significant concerns exist with regard to the long-term durability of CPE bearings in young, moderately active patients 15 years after THA. These patients should be followed closely for wear-related problems. Our results should be used as a comparison when evaluating the outcomes of more modern bearing surface combinations. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:3712 / 3718
页数:7
相关论文
共 50 条
  • [41] Redefining Indications for Modern Cementless Total Knee Arthroplasty: Clinical Outcomes and Survivorship in Patients &gt;75 Years Old
    Goh, Graham S.
    Fillingham, Yale A.
    Ong, Christian B.
    Krueger, Chad A.
    Courtney, P. Maxwell
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (03): : 476 - +
  • [42] Activity Levels and Functional Outcomes of Young Patients Undergoing Total Hip Arthroplasty
    Malcolm, Tennison L.
    Szubski, Caleb R.
    Nowacki, Amy S.
    Klika, Alison K.
    Iannotti, Joseph P.
    Barsoum, Wael K.
    ORTHOPEDICS, 2014, 37 (11) : E983 - E992
  • [43] Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30
    Pakos, Emilios E.
    Paschos, Nikolaos K.
    Xenakis, Theodoros A.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2014, 2 (03): : 157 - 162
  • [44] Influence of Prior Hip Salvage Surgery on Outcomes After Total Hip Arthroplasty in Young Patients
    George, Jaiben
    Miller, Evan M.
    Higuera, Carlos A.
    Kuivila, Thomas E.
    Mont, Michael A.
    Goodwin, Ryan C.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1108 - 1112
  • [45] Relationship between the hip movements during walking and the polyethylene wear in Charnley's cemented total hip arthroplasty.
    Mejjad, O
    Dujardin, FH
    Toupin, JM
    DaSilva, LF
    Weber, J
    Thomine, JM
    LeLoet, X
    ARTHRITIS AND RHEUMATISM, 1996, 39 (09): : 882 - 882
  • [46] Ten-year survivorship of primary total hip arthroplasty in patients 30 years of age or younger
    Makarewich, C. A.
    Anderson, M. B.
    Gililland, J. M.
    Pelt, C. E.
    Peters, C. L.
    BONE & JOINT JOURNAL, 2018, 100B (07): : 867 - 874
  • [47] Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years
    Jonsson, B. A.
    Kadar, T.
    Havelin, L. I.
    Haugan, K.
    Espehaug, B.
    Indrekvam, K.
    Furnes, O.
    Hallan, G.
    BONE & JOINT JOURNAL, 2015, 97B (11): : 1463 - 1469
  • [48] Long-Term Follow-Up of Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Heightened Wear-Related Complications Are Observed at the Beginning of the Third Decade
    Parilla, Frank W.
    Ince, Deniz C.
    Pashos, Gail E.
    Maloney, William J.
    Clohisy, John C.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (09): : 1816 - 1821
  • [49] Highly cross-linked polyethylene improves wear and mid-term failure rates for young total hip arthroplasty patients
    Keeney, James A.
    Martell, John M.
    Pashos, Gail
    Nelson, Christopher J.
    Maloney, William J.
    Clohisy, John C.
    HIP INTERNATIONAL, 2015, 25 (05) : 435 - 441
  • [50] Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty
    Buckner, Brandt C.
    Urban, Nathanael D.
    Cahoy, Kevin M.
    Lyden, Elizabeth R.
    Deans, Christopher F.
    Garvin, Kevin L.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 38 - 43