Denoising of time-density data in digital subtraction angiography

被引:0
|
作者
Bogunovic, H [1 ]
Loncaric, S [1 ]
机构
[1] Univ Zagreb, Fac Elect Engn & Comp, Zagreb 10000, Croatia
来源
IMAGE ANALYSIS, PROCEEDINGS | 2005年 / 3540卷
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper we present methods for removing the noise from a time sequence of digitally subtracted x-ray angiographic images. By observing the contrast agent propagation profile in a region of the angiogram one can estimate the time of arrival of that agent. Due to the large level of noise, it is difficult to detect the moment of the contrast agent arrival accurately. Hence denoising is required. Two methods are presented. The first one is based on 1D Wiener filtering of the time data. Wiener filter was chosen because it presents the optimal linear filter in the least-squares sense. The other method is based on 3D wavelet denoising via wavelet shrinkage technique, which is a nonlinear method. Since it is based on 3D wavelet basis it can perform denoising simultaneously in the spatial as well as in the time dimension of the image sequence. Wavelet based denoising proved to be superior but computationally more demanding. The experiments were performed on a sequence of cerebral angiograms.
引用
收藏
页码:1157 / 1166
页数:10
相关论文
共 50 条
  • [31] VIDEODENSITOMETRIC QUANTITATION OF AORTIC REGURGITATION BY DIGITAL SUBTRACTION AORTOGRAPHY USING A COMPUTER-BASED METHOD ANALYZING TIME-DENSITY CURVES
    KLEIN, LW
    AGARWAL, JB
    STETS, G
    RUBINSTEIN, RI
    WEINTRAUB, WS
    HELFANT, RH
    AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (09): : 753 - 756
  • [32] Pulmonary digital subtraction angiography: Ready for prime time
    Darcy, MD
    RADIOLOGY, 1998, 207 (01) : 11 - 12
  • [33] PULMONARY DIGITAL SUBTRACTION ANGIOGRAPHY - A METHOD FOR CHARACTERIZING PERFUSION BY MEANS OF TIME-DENSITY-CURVES
    RICHTER, C
    SCHRODER, G
    ZEITSCHRIFT FUR KLINISCHE MEDIZIN-ZKM, 1988, 43 (22): : 1939 - 1942
  • [34] Rotational digital subtraction carotid angiography: Technique and comparison with static digital subtraction angiography
    Bosanac, Z
    Miller, RJ
    Jain, M
    CLINICAL RADIOLOGY, 1998, 53 (09) : 682 - 687
  • [35] Rotational digital subtraction carotid angiography: Technique and comparison with static digital subtraction angiography
    Bosanac, ZB
    Miller, R
    RADIOLOGY, 1998, 209P : 278 - 279
  • [36] Evaluation of intra-aneurysmal blood flow by time density curve using digital subtraction angiography
    Tenjin, H
    Asakura, F
    Nakahara, Y
    Matsumoto, K
    Matsuo, T
    Urano, F
    Ueda, S
    STROKE, 1998, 29 (01) : 311 - 311
  • [37] PEDIATRIC DIGITAL SUBTRACTION ANGIOGRAPHY
    TSCHAPPELER, H
    TRILLER, J
    FRITSCHY, P
    PEDIATRIC RADIOLOGY, 1986, 16 (04) : 341 - 342
  • [38] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY
    BUTLER, P
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1986, 35 (01): : 30 - &
  • [39] DIGITAL SUBTRACTION ANGIOGRAPHY WITH IOHEXOL
    CACAYORIN, ED
    BERNSTEIN, AD
    FRUEHAN, CT
    NAGLE, RW
    LEE, SH
    KIEFFER, SA
    RADIOLOGY, 1982, 144 (04) : 961 - 961
  • [40] DIGITAL SUBTRACTION ANGIOGRAPHY IN NEURORADIOLOGY
    ENZMANN, DR
    KWAN, E
    LEWIS, D
    BRODY, WR
    NEURORADIOLOGY, 1984, 26 (02) : 164 - 164