Multivariate calibration standardization across instruments for the determination of glucose by Fourier transform near-infrared spectrometry

被引:45
|
作者
Zhang, L
Small, GW [1 ]
Arnold, MA
机构
[1] Ohio Univ, Ctr Intelligent Chem Instrumentat, Dept Chem & Biochem, Clippinger Labs, Athens, OH 45701 USA
[2] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
关键词
D O I
10.1021/ac034495x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The transfer of multivariate calibration models is investigated between a primary (A) and two secondary Fourier transform near-infrared (near-IR) spectrometers (13, Q. The application studied in this work is the use of bands in the near-IR combination region of 5000-4000 cm(-1) to determine physiological levels of glucose in a buffered aqueous matrix containing varying levels of alanine, ascorbate, lactate, triacetin, and urea. The three spectrometers are used to measure 80 samples produced through a randomized experimental design that minimizes correlations between the component concentrations and between the concentrations of glucose and water. Direct standardization (DS), piecewise direct standardization (PDS), and guided model reoptimization (GMR) are evaluated for use in transferring partial least-squares calibration models developed with the spectra of 64 samples from the primary instrument to the prediction of glucose concentrations in 16 prediction samples measured with each secondary spectrometer. The three algorithms are evaluated as a function of the number of standardization samples used in transferring the calibration models. Performance criteria for judging the success of the calibration transfer are established as the standard error of prediction (SEP) for internal calibration models built with the spectra of the 64 calibration samples collected with each secondary spectrometer. These SEP values are 1.51 and 1.14 mM for spectrometers B and C, respectively. When calibration standardization is applied, the GMR algorithm is observed to outperform DS and PDS. With spectrometer C, the calibration transfer is highly successful, producing an SEP value of 1.07 mM. However, an SEP of 2.96 mM indicates unsuccessful calibration standardization with spectrometer B. This failure is attributed to differences in the variance structure of the spectra collected with spectrometers A and B. Diagnostic procedures are presented for use with the GMR algorithm that forecasts the successful calibration transfer with spectrometer C and the unsatisfactory results with spectrometer B.
引用
收藏
页码:5905 / 5915
页数:11
相关论文
共 50 条
  • [31] Applications of Fourier transform infrared spectroscopy, Fourier transform infrared microscopy and near-infrared spectroscopy to cancer research
    Yano, K
    Sakamoto, Y
    Hirosawa, N
    Tonooka, S
    Katayama, H
    Kumaido, K
    Satomi, A
    [J]. SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2003, 17 (2-3): : 315 - 321
  • [32] Fourier Transform Spectrometry with a Near Infrared Supercontinuum Source
    Michaels, Chris A.
    Masiello, Tony
    Chu, Pamela M.
    [J]. 2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 369 - 370
  • [33] MOISTURE DETERMINATION BY NEAR-INFRARED SPECTROMETRY
    VORNHEDER, PF
    BRABBS, WJ
    [J]. ANALYTICAL CHEMISTRY, 1970, 42 (12) : 1454 - +
  • [34] Fourier transform spectrometry with a near infrared supercontinuum source
    Chu, Pamela M.
    Michaels, Chris A.
    Masiello, Tony
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [35] Heterodyne Fourier transform spectrometer for the near-infrared region
    Hirai, A
    Matsumoto, H
    Lin, DJ
    Tagaki, C
    [J]. OPTICS EXPRESS, 2003, 11 (11): : 1258 - 1264
  • [36] Near-Infrared Fourier Transform Raman Spectroscopy of Indigoids
    Tatsch, E.
    Schrader, B.
    [J]. Journal of Raman Spectroscopy, 26 (06):
  • [37] Wavelet hybrid direct standardization of near-infrared multivariate calibrations
    Tan, HW
    Brown, SD
    [J]. JOURNAL OF CHEMOMETRICS, 2001, 15 (08) : 647 - 663
  • [38] Fast calibration of photodiodes in the near-infrared, visible and ultraviolet using a Fourier-transform spectrometer
    Werner, L
    Fischer, J
    [J]. METROLOGIA, 1998, 35 (04) : 403 - 406
  • [39] Determination of triglycerides in human plasma using near-infrared spectroscopy and multivariate calibration methods
    da Costa, PA
    Poppi, RJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 446 (1-2) : 39 - 47
  • [40] Quantitative determination of epoxidized soybean oil using near-infrared spectroscopy and multivariate calibration
    Parreira, TF
    Ferreira, MMC
    Sales, HJS
    de Almeida, WB
    [J]. APPLIED SPECTROSCOPY, 2002, 56 (12) : 1607 - 1614