Characterization of a Molecular Breast Imaging system in Limited Angle Tomography using a dedicated breast phantom

被引:1
|
作者
Poma, G. E. [1 ,2 ]
Cisbani, E. [3 ]
Nuyts, J. [7 ]
Giuliani, F. [3 ]
Insero, T. [4 ]
Lucentini, M. [3 ]
Marcucci, A. [5 ]
Musico, P. [6 ]
Santavenere, F. [3 ]
Sutera, C. [1 ]
Garibaldi, F. [3 ]
机构
[1] INFN, Sez Catania, Via S Sofia 64, I-95123 Catania, Italy
[2] Univ Catania, Dipartimento Fis & Astron, Via S Sofia 64, I-95123 Catania, Italy
[3] ISS, Viale Regina Elena 199, I-00161 Rome, Italy
[4] Osped Pediat Bambin Gesu, Viale San Paolo 15, I-00146 Rome, Italy
[5] Aeronaut Mil Italiana, Viale Univ 4, I-00185 Rome, Italy
[6] INFN, Sez Genova, Via Dodecaneso 33, I-16146 Genoa, Italy
[7] Univ Leuven, KU Leuven, Dept Imaging & Pathol, Nucl Med & Mol Imaging,Med Imaging Res Ctr MIRC, B-3000 Leuven, Belgium
来源
JOURNAL OF INSTRUMENTATION | 2020年 / 15卷 / 02期
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPGe; HgI etc); Image reconstruction in medical imaging; MODALITY;
D O I
10.1088/1748-0221/15/02/C02046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work reports on the Limited Angle Tomography (LAT) studies of a novel Molecular Breast Imaging (MBI) system with radionuclides, made by two asymmetric SPECT-like detector heads with two different optics. MBI has a central role to play in detecting the small breast tumours, especially for dense breasts, due to its specificity in detecting tumours even in dense breasts. For this purpose, an innovative device has been developed at ISS in Rome, composed of a dual detector setup which combines images from two complementary detectors at the opposite sides of the compressed breast, and that allows spot compression and LAT for a tumour 3-D reconstruction. Our study tries to demonstrate the feasibility of using this novel system in LAT , where a small detector head with pinhole collimator is able to rotate around the breast phantom, to diagnose the small tumours and to improve the sensitivity and efficiency. Detector heads and phantom, LAT setup and first preliminary results, are presented.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Heterogeneous breast phantom for computed tomography and magnetic resonance imaging
    Saleh, Gameel
    Abuelhaija, Ashraf
    Alfaris, Budour
    Aljabr, Aljohara
    Zainalabedin, Maryam
    Mhareb, M. H. A.
    Alhashim, Maryam
    Alenezi, Salma
    PLOS ONE, 2023, 18 (04):
  • [22] Quantitative characterization of breast tissues with dedicated CT imaging
    Piai, Anna
    Contillo, Adriano
    Arfelli, Fulvia
    Bonazza, Deborah
    Brombal, Luca
    Cova, Maria Assunta
    Delogu, Pasquale
    Di Trapani, Vittorio
    Donato, Sandro
    Golosio, Bruno
    Mettivier, Giovanni
    Oliva, Piernicola
    Rigon, Luigi
    Taibi, Angelo
    Tonutti, Maura
    Tromba, Giuliana
    Zanconati, Fabrizio
    Longo, Renata
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15):
  • [23] Molecular Imaging Using Light-Absorbing Imaging Agents and a Clinical Optical Breast Imaging System-a Phantom Study
    van de Ven, Stephanie M. W. Y.
    Mincu, Niculae
    Brunette, Jean
    Ma, Guobin
    Khayat, Mario
    Ikeda, Debra M.
    Gambhir, Sanjiv S.
    MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (02) : 232 - 238
  • [24] Design considerations for a limited-angle, dedicated breast, TOF PET scanner
    Surti, Suleman
    Karp, Joel S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3667 - 3672
  • [25] Confocal Imaging of Breast Tumor Phantom Using 3-D-Printed Breast Phantom
    Kono, Hayato
    Sugitani, Takumi
    Xiao, Xia
    Aritome, Katsuhiro
    Miyake, Ryo
    Kikkawa, Takamaro
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 530 - 531
  • [26] Dosimetric characterization of a dedicated breast computed tomography clinical prototype
    Sechopoulos, Ioannis
    Feng, Steve Si Jia
    D'Orsi, Carl J.
    MEDICAL PHYSICS, 2010, 37 (08) : 4110 - 4120
  • [27] Physical Breast Phantom Dedicated for Mammography Studies
    Feradov, Firgan
    Marinov, Stoyko
    Bliznakova, Kristina
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 344 - 352
  • [28] A Heterogeneous Breast Phantom for Microwave Breast Imaging
    Ostadrahimi, Majid
    Reopelle, Ryan
    Noghanian, Sima
    Pistorius, Stephen
    Vahedi, Arman
    Safari, Faezeh
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2727 - 2730
  • [29] Newer Technologies in Breast Cancer Imaging: Dedicated Cone-Beam Breast Computed Tomography
    O'Connell, Avice M.
    Karellas, Andrew
    Vedantham, Srinivasan
    Kawakyu-O'Connor, Daniel T.
    SEMINARS IN ULTRASOUND CT AND MRI, 2018, 39 (01) : 106 - 113
  • [30] A Dedicated Breast PET-CT System for Metabolic Imaging of Breast Tumors
    Magometschnigg, H.
    Pinker-Domenig, K.
    Bickel, H.
    Brueck, B.
    Mayerhoefer, M.
    Schernthaner, M.
    Helbich, T.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S64 - S64