A geometric method of measuring the left ventricular ejection fraction on gated Tc-99m sestamibi myocardial imaging

被引:5
|
作者
Miron, SD [1 ]
Finkelhor, R [1 ]
Penuel, PH [1 ]
Bahler, R [1 ]
Bellon, EM [1 ]
机构
[1] CASE WESTERN RESERVE UNIV,METROHEALTH MED CTR,DEPT MED,DIV CARDIOL,CLEVELAND,OH 44109
关键词
D O I
10.1097/00003072-199606000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Geometric measurements of the left ventricular diameters as used in biplane angiocardiography and echocardiography were applied to gated SPECT Tc-99m sestamibi myocardial scintigrams in order to calculate the left ventricular ejection fraction. These measurements take no longer than 5 minutes and require no additional computer software. In a review of 79 examinations, the left ventricular ejection fraction calculated using these measurements correlated well with the echocardiographically estimated ejection fraction (r = 0.78, P < 0.0001). The technique is highly reproducible with an intraobserver correlation of r = 0.94 and interobserver correlation of r = 0.93.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 50 条
  • [1] A geometric method of measuring the left ventricular ejection fraction on gated Tc-99m sestamibi myocardial imaging (vol 21, pg 439, 1996)
    Miron, SD
    Finkelhor, R
    Penuel, PH
    Bahler, R
    Bellon, EM
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (08) : 663 - 663
  • [2] MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION FROM GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    BOONYAPRAPA, S
    EKMAHACHAI, M
    THANACHAIKUN, N
    JAIPRASERT, W
    SUKTHOMYA, V
    PORAMATIKUL, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06): : 528 - 531
  • [3] EJECTION FRACTION WITH PLANAR GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    SZULC, M
    HERROLD, EM
    ZANZONICO, P
    BORER, JS
    CLINICAL RESEARCH, 1993, 41 (03): : A610 - A610
  • [4] EJECTION FRACTION WITH PLANAR GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    SZULC, M
    HERROLD, EM
    ZANZONICO, P
    BORER, JS
    CIRCULATION, 1993, 88 (04) : 582 - 582
  • [5] Automated calculation of left ventricular ejection fraction from gated Tc-99m sestamibi myocardial images - Comparison to quantitative echocardiography
    Zanger, DR
    Bhatnagar, A
    Hausner, E
    Botello, MF
    Nuquist, CE
    Martinez, AI
    Welssman, NJ
    Cerqueira, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 98546 - 98546
  • [6] Gated SPECT Tc-99m N-NOET myocardial perfusion studies provide similar information regarding left ventricular ejection fraction and volumes as Tc-99m sestamibi.
    Magram, MY
    Line, BR
    Zinnes, A
    Lodge, MA
    Magram, DN
    Shankovich, A
    Bacetti, N
    Dilsizian, V
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 86P - 87P
  • [7] Impact of gender on rest Tc-99m sestamibi-gated left ventricular election fraction
    Kane, GC
    Hauser, MF
    Behrenbeck, TR
    Miller, TD
    Gibbons, RJ
    Christian, TF
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (10): : 1238 - +
  • [8] AUTOMATIC-MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION BY GATED SPECT TC-99M SESTAMIBI - A COMPARISON WITH RADIONUCLIDE VENTRICULOGRAPHY
    MORIEL, M
    GERMANO, G
    KIAT, H
    FRIEDMAN, J
    HYUN, M
    TINKER, T
    BERMAN, DS
    CIRCULATION, 1993, 88 (04) : 582 - 582
  • [9] Left ventricular ejection fraction determined by gated perfusion tomography with thallium-201 and Tc-99m sestamibi and by first pass imaging: Effect of depressed left ventricular function
    He, ZX
    Mahmarian, JJ
    Preslar, JS
    Verani, MS
    CIRCULATION, 1997, 96 (08) : 2109 - 2109
  • [10] Quantitative left ventricular ejection fraction derived from gated Tl-201 perfusion SPECT: Comparison with gated Tc-99m sestamibi SPECT
    Erel, J
    Germano, G
    Kiat, H
    Friedman, JD
    Kavanagh, PB
    Berman, DS
    CIRCULATION, 1996, 94 (08) : 1766 - 1766