Prevention of short term reversible chronic atrial fibrillation by permanent pacing at the triangle of Koch

被引:17
|
作者
Padeletti, L [1 ]
Porciani, MC [1 ]
Michelucci, A [1 ]
Colella, A [1 ]
Costoli, A [1 ]
Ciapetti, C [1 ]
Pieragnoli, P [1 ]
Musilli, N [1 ]
Gensini, GF [1 ]
机构
[1] Univ Florence, Inst Internal Med & Cardiol, I-50134 Florence, Italy
关键词
atrial fibrillation; atrial pacing; electrical cardioversion;
D O I
10.1023/A:1026557313240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of this study was to investigate if single lead interatrial septum pacing could be effective in maintaining sinus rhythm in patients in whom restoration of sinus rhythm was only possible for a period of 2-24 hours after one or more previous electrical cardioversions, and in whom a sinus bradycardia was documented before arrhythmia restarted. The two hours limit was chosen because it was considered a sufficient time to implant a dual chamber pacemaker. Background: Alternative atrial pacing techniques have been demonstrated to be successful in preventing recurrences of atrial fibrillation (AF) in patients with sinus bradycardia. Excluding the AF occurring after only a few sinus beats, at 24 hours from electrical cardioversion an early restart of chronic AF has been reported in 12% to 17% of the patients. Methods: After sinus rhythm was restored by internal electrical cardioversion, 17 patients, 7 ablated at the AV junction, underwent a dual chamber rate response (DDDR) pacemaker implantation with a screw-in atrial lead placed in the interatrial septum. Results: After a follow-up period of 17 +/- 5 months (range 12 to 27 months) persistence of sinus rhythm was observed in 11 patients (65%). Six patients (35%) had recurrences of paroxysmal attacks, while five (30%) were totally free of AF. Recurrence of chronic AF was observed in six cases (35%) after 2 days-12 months from implantation. No dislodgements of the atrial lead and no complications were observed at implantation and during follow-up. Conclusions: Interatrial septum pacing is a safe and feasible technique with a satisfying success rate (65%) in long-term maintaining sinus rhythm in previously unsuccessfully cardioverted patients.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 50 条
  • [31] Anodal pacing reversion in short-term canine atrial fibrillation model
    Oke, L
    Mower, MM
    Cothran, LV
    Coleman, B
    Huang, Z
    Tearney, R
    Ball, C
    Watson, S
    FASEB JOURNAL, 2000, 14 (04): : A697 - A697
  • [32] Anodal pacing reversion in short-term canine atrial fibrillation model
    Oke, L
    Mower, MM
    Cothran, LV
    Coleman, B
    Huang, Z
    Tearney, R
    Ball, C
    Watson, S
    JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (02) : 199A - 199A
  • [33] Dynamic atrial pacing (DAOTM) and multisite atrial pacing for prevention of atrial fibrillation:: The stadim trial
    Senatore, G
    Fazzari, M
    De Simone, A
    Stabile, G
    Vasquez, L
    Maddalon, M
    Moro, E
    EUROPACE 2001, 2001, : 413 - 417
  • [34] Atrial pacing for the prevention of atrial fibrillation after cardiovascular surgery
    Greenberg, MD
    Katz, NM
    Iuliano, S
    Tempesta, BJ
    Solomon, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) : 1416 - 1422
  • [35] Multisite atrial pacing: An option for atrial fibrillation prevention? Preliminary results of the Dutch Dual-site Right Atrial Pacing for Prevention of Atrial Fibrillation study
    Misier, ARR
    Beukema, WP
    Luttikhuis, HAO
    Willems, R
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (9A): : 20K - 24K
  • [36] PERMANENT ATRIAL-PACING FOR TREATMENT OF CHRONIC RECURRENT IDIOPATHIC VENTRICULAR-TACHYCARDIA AND FIBRILLATION
    DAVY, JM
    LEGULUDEC, D
    SIRINELLI, A
    SEBAG, C
    MOTTE, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 997 - 997
  • [37] Evaluation of bi-atrial pacing and single site right atrial pacing for the prevention of atrial fibrillation
    Enjoji, Y
    Sugi, K
    Noro, M
    Nakae, T
    Tezuka, N
    Takami, M
    Kawase, A
    Kumagai, K
    Sakai, T
    Ikeda, T
    Yamaguchi, T
    CIRCULATION JOURNAL, 2002, 66 (01) : 70 - 74
  • [38] Is overdrive pacing useful for the prevention of paroxysmal atrial fibrillation?
    Attuel, P
    El Allaf, D
    Konz, KH
    Szendey, I
    Brachmann, J
    Schibgilla, V
    Danilovic, D
    CARDIAC ARRHYTHMIAS 2001, 2002, : 492 - 497
  • [39] Multisite or alternate site pacing for the prevention of atrial fibrillation
    Misier, ARR
    Beukema, WP
    Luttikhuis, HAO
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (5B): : 237D - 240D
  • [40] Local capture by atrial pacing in spontaneous chronic atrial fibrillation
    Pandozi, C
    Bianconi, L
    Villani, M
    Castro, A
    Altamura, G
    Toscano, S
    Jesi, AP
    Gentilucci, G
    Ammirati, F
    LoBianco, F
    Santini, M
    CIRCULATION, 1997, 95 (10) : 2416 - 2422