Spectral Phase Measurements of Heterodyne Detection in Interfacial Broadband Electronic Spectroscopy

被引:12
|
作者
Zhang, Tong [1 ,2 ,3 ,4 ]
Huangfu, Zhi-Chao [4 ]
Qian, Yuqin [4 ]
Lu, Zhou [5 ]
Gao, Hong [1 ,2 ]
Rao, Yi [4 ]
机构
[1] Chinese Acad Sci, Inst Chem, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Inst Chem, State Key Lab Mol React Dynam, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Utah State Univ, Dept Chem & Biochem, Logan, UT 84322 USA
[5] Anhui Normal Univ, Sch Phys Elect Informat, Anhui Prov Key Lab Optoelect Mat Sci & Technol, Wuhu 241002, Anhui, Peoples R China
来源
JOURNAL OF PHYSICAL CHEMISTRY C | 2022年 / 126卷 / 05期
基金
美国国家科学基金会;
关键词
SUM-FREQUENCY GENERATION; VIBRATIONAL SPECTROSCOPY; AIR/WATER INTERFACE; LIQUID INTERFACES; 2ND-HARMONIC GENERATION; MOLECULAR-ORIENTATION; MONOLAYERS; SURFACES; WATER; GOLD;
D O I
10.1021/acs.jpcc.1c09692
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A spectral phase is vital to retrieve both the real and imaginary parts of both second-order vibrational and electronic sum frequency generation spectra. Despite recent efforts, phase measurements in electronic spectra at interfaces are lacking. In particular, references are not well established for frequency-dependent spectral phases in interfacial electronic spectroscopy. In this work, we present broadband heterodyne detection (HD) of interfacial electronic spectroscopy for spectral phases of references. Such a broadband HD method was based upon a broadband short-wave IR laser source from 1100 to 2200 nm. A collinear geometry method was adopted for passive phase stability. We further compared often-used reference samples, including gold (Au) thin films, silver (Ag) thin films, p-type GaP (100), p-type GaAs (100), as well as left-handed and right-handed z-cut alpha-quartz crystals. The phases of the second-order susceptibilities for Ag thin films, the GaP crystal, the GaAs crystal, and the quartz crystals are independent of frequency from 630 to 730 nm. More importantly, it was found that the often-used Au thin film in the literature is not a good phase reference for frequency-dependent phases.
引用
收藏
页码:2823 / 2832
页数:10
相关论文
共 50 条
  • [31] Measuring buried interfacial electronic structure using heterodyne detected electronic sum frequency generation
    Moon, Aaron
    Bender, Jon
    Cotton, Daniel
    Renard, Benny
    Roberts, Sean
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [32] Self-Heterodyne Detection for SNR Improvement and Distributed Phase-Shift Measurements in BOTDA
    Zornoza, Ander
    Sagues, Mikel
    Loayssa, Alayn
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2012, 30 (08) : 1066 - 1072
  • [33] Frequency-Resolved Detection of Broadband THz Waves with Cherenkov-Phase-Matched Heterodyne EO Sampling
    Tani, Masahiko
    Azuma, Syougo
    Nagase, Tomohiro
    Ozawa, Shinpei
    Funkner, Stefan
    Niehues, Gudrun
    Iwamae, Atsushi
    Yamamoto, Kohji
    Furuya, Takashi
    Estacio, Elmer
    Bakunov, Michael I.
    [J]. 2014 39TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2014,
  • [34] Tunable spatial heterodyne spectroscopy (TSHS): a new technique for broadband visible interferometry
    Hosseini, S. Sona
    Gong, Aaron
    Ruth, Dustin
    Baldis, Hector A.
    Harris, Walter
    [J]. OPTICAL AND INFRARED INTERFEROMETRY II, 2010, 7734
  • [35] Heterodyne terahertz detection through electronic and optoelectronic mixers
    Lin, Yen-Ju
    Jarrahi, Mona
    [J]. REPORTS ON PROGRESS IN PHYSICS, 2020, 83 (06)
  • [36] Electronic resonances in broadband stimulated Raman spectroscopy
    Batignani, G.
    Pontecorvo, E.
    Giovannetti, G.
    Ferrante, C.
    Fumero, G.
    Scopigno, T.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [37] Electronic resonances in broadband stimulated Raman spectroscopy
    G. Batignani
    E. Pontecorvo
    G. Giovannetti
    C. Ferrante
    G. Fumero
    T. Scopigno
    [J]. Scientific Reports, 6
  • [38] The Research of Spatial Heterodyne Raman Spectroscopy with Standoff Detection
    Hu Guang-xiao
    Xiong Wei
    Luo Hai-yan
    Shi Hai-liang
    Li Zhi-wei
    Shen Jing
    Fang Xue-jing
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (12) : 3951 - 3957
  • [39] EQUIPMENT FOR PHOTON-CORRELATION SPECTROSCOPY MEASUREMENTS IN THE HETERODYNE MODE
    SASAKI, S
    MANDEL, M
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09): : 738 - 740
  • [40] Broadband cavity-enhanced absorption spectroscopy in the ultraviolet spectral region for measurements of nitrogen dioxide and formaldehyde
    Washenfelder, R. A.
    Attwood, A. R.
    Flores, J. M.
    Zarzana, K. J.
    Rudich, Y.
    Brown, S. S.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (01) : 41 - 52