Removal of adenovirus, calicivirus, and bacteriophages by conventional drinking water treatment
被引:19
|
作者:
Abbaszadegan, Morteza
论文数: 0引用数: 0
h-index: 0
机构:
Arizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USAArizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
Abbaszadegan, Morteza
[1
]
Monteiro, Patricia
论文数: 0引用数: 0
h-index: 0
机构:
Univ Brasilia, Dept Civil & Environm Engn, Brasilia, DF, BrazilArizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
Monteiro, Patricia
[2
]
Nwachuku, Nena
论文数: 0引用数: 0
h-index: 0
机构:
US EPA, Off Sci & Technol, Off Water, Washington, DC 20460 USAArizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
Nwachuku, Nena
[3
]
Alum, Absar
论文数: 0引用数: 0
h-index: 0
机构:
Arizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USAArizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
Alum, Absar
[1
]
Ryu, Hodon
论文数: 0引用数: 0
h-index: 0
机构:
Arizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USAArizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
Ryu, Hodon
[1
]
机构:
[1] Arizona State Univ, Dept Civil & Environm Engn, Natl Sci Fdn, Water Qual Ctr, Tempe, AZ 85287 USA
adenovirus;
calicivirus;
MS-2;
fr;
PRD-1;
Phi X-174;
conventional drinking water treatment;
pilot plant study;
D O I:
10.1080/10934520701781541
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
This study was conducted to evaluate the removal of adenovirus, feline calicivirus (FCV), and bacteriophages MS-2, fr, PRD-1, and Phi X-174 during conventional drinking water treatment using ferric chloride as a coagulant. Adenovirus and FCV were removed to a greater extent than PRD-1 and Phi X-174, indicating that these bacteriophages may be appropriate surrogates for both adenovirus and FCV. Of the four bacteriophages studied in the pilot plant, MS-2 was removed to the greatest extent (5.1 log), followed by fr (4.9 log), PRD-1 (3.5 log), and Phi X-174 (1.3 log). The virus removal trend in the pilot-scale testing was similar to the bench-scale testing; however, the bench-scale testing seemed to provide a conservative estimate of the pilot plant performance. In the pilot-scale testing, MS-2 and fr were removed with the greatest efficiency during filtration, whereas PRD-1 and Phi X-174 showed the greatest removal during sedimentation.
机构:
Institute of Environmental and Water Resource Management, Faculty of Civil Engineering, Universiti Teknologi MalaysiaInstitute of Environmental and Water Resource Management, Faculty of Civil Engineering, Universiti Teknologi Malaysia
Ng K.-S.
Ujang Z.
论文数: 0引用数: 0
h-index: 0
机构:
Institute of Environmental and Water Resource Management, Faculty of Civil Engineering, Universiti Teknologi MalaysiaInstitute of Environmental and Water Resource Management, Faculty of Civil Engineering, Universiti Teknologi Malaysia
Ujang Z.
Le-Clech P.
论文数: 0引用数: 0
h-index: 0
机构:
UNESCO Centre for Membrane Science and Technology, School of Chemical Engineering and Industrial Chemistry, University of New South WalesInstitute of Environmental and Water Resource Management, Faculty of Civil Engineering, Universiti Teknologi Malaysia