Comparative study of methods for measuring window film UV and luminous transmittance

被引:0
|
作者
Caly, Jose P. [1 ]
Ferreira, Antonio F. G., Jr. [1 ]
机构
[1] IPT, Inst Technol Res, BR-05508901 Sao Paulo, SP, Brazil
关键词
D O I
10.1088/1742-6596/575/1/012022
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This work presents a comparison of window film ultraviolet transmission calculated according ISO 13837 methods A and B and window film luminous transmission calculated for illuminates A and D65. The results show a difference from 350% to 800% in ultraviolet transmission between ISO 13837 methods A and B for the evaluated window films. On the other hand, the difference in luminous transmission results for the evaluated window films is less than 1%.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A comparative study of two different methods for measuring cardiac output
    Parke, Rachael L.
    Reed, Peter W.
    Beca, John S.
    McGuiness, Shay P.
    [J]. AUSTRALIAN CRITICAL CARE, 2009, 22 (01) : 55 - 55
  • [22] A Comparative Study of Three Methods of Measuring Flat and Weak Feet
    Danford, Harold R.
    [J]. RESEARCH QUARTERLY, 1935, 6 (01): : B43 - B49
  • [23] Comparative study of methods of measuring acute pain intensity in an ED
    Berthier, F
    Potel, G
    Leconte, P
    Touze, MD
    Baron, D
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1998, 16 (02): : 132 - 136
  • [24] COMPARATIVE STUDY OF 3 METHODS MEASURING BLOOD-GLUCOSE
    SCARDINO, V
    RUBENS, SH
    GHOSH, NK
    [J]. CLINICAL CHEMISTRY, 1972, 18 (07) : 706 - &
  • [25] Synergistic TiO2/VO2 Window Coating with Thermochromism, Enhanced Luminous Transmittance, and Photocatalytic Activity
    Ji, Yuxia
    Mattsson, Andreas
    Niklasson, Gunnar A.
    Granqvist, Claes G.
    Osterlund, Lars
    [J]. JOULE, 2019, 3 (10) : 2457 - 2471
  • [26] A temperature-responsive polyurethane film with reversible visible light transmittance change and constant low UV light transmittance
    Xiao, Y.
    Wu, B.
    Liu, Z.
    Jiang, L.
    Lei, J.
    Wang, R.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2019, 136 (09)
  • [27] A NEW METHOD OF MEASURING INVIVO THE LENS TRANSMITTANCE, AND STUDY OF LENS SCATTER, FLUORESCENCE AND TRANSMITTANCE
    ZEIMER, RC
    NOTH, JM
    [J]. OPHTHALMIC RESEARCH, 1984, 16 (05) : 246 - 255
  • [28] A Comparative Study on Titanium Dioxide Sol-gel Treatment for Protein Fabrics, Focusing on UV Transmittance Effects
    Zhang, Hu
    Deb-Choudhury, Santanu
    Plowman, Jeffrey
    Harland, Duane
    Dyer, Jolon
    [J]. FIBERS AND POLYMERS, 2014, 15 (11) : 2335 - 2339
  • [29] A comparative study on titanium dioxide sol-gel treatment for protein fabrics, focusing on UV transmittance effects
    Hu Zhang
    Santanu Deb-Choudhury
    Jeffrey Plowman
    Duane Harland
    Jolon Dyer
    [J]. Fibers and Polymers, 2014, 15 : 2335 - 2339
  • [30] Measuring solar UV radiation with EBT radiochromic film
    Butson, Ethan T.
    Cheung, Tsang
    Yu, Peter K. N.
    Butson, Martin J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (20): : N487 - N493