A portable system for autoregulation and wireless control of sensorized left ventricular assist devices

被引:2
|
作者
Fontana, Rossella [1 ]
Tortora, Giuseppe [1 ]
Silvestri, M. [1 ]
Vatteroni, M. [1 ,2 ]
Dario, Paolo [1 ]
Trivella, M. G. [3 ]
机构
[1] Scuola Super Sant Anna, BioRobot Inst, I-56100 Pisa, Italy
[2] Univ Lyon 1, Inst Analyt Sci, F-69365 Lyon, France
[3] CNR, Inst Clin Physiol, Pisa, Italy
关键词
Heart failure; Sensorized LVADs; Portable monitoring and autoregulation unit; Safety unit; Wireless monitoring; ADAPTIVE-CONTROL; PUMP SPEED; BLOOD-FLOW; BRIDGE; TRANSPLANTATION; EXERCISE;
D O I
10.1016/j.bbe.2016.02.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
End stage heart failure patients could benefit from left ventricular assist device (LVAD) implantation as bridge to heart transplantation or as destination therapy. However, LVAD suffers from several limitations, including the presence of a battery as power supply, the need for cabled connection from inside to outside the patient, and the lack of autonomous adaptation to the patient metabolic demand during daily activity. The authors, in this wide scenario, aim to contribute to advancement of the LVAD therapy by developing the hardware and the firmware of a portable autoregulation unit (ARU), able to fulfill the needs of sensorized VAD in terms of physic/physiological data storing, continuous monitoring, wireless control from the external environment and automatic adaptation to patient activities trough the implementation of autoregulation algorithms. Moreover, in order to answer the rules and safety requirements for implantable biomedical devices, a user control interface (UCI), was developed and associated to the ARU for an external manual safe control. The ARU and UCI functionalities and autoregulation algorithms have been successfully tested on bench and on animal, with a response time of 1 s for activating autoregulation algorithms. Animal experiments showed as the presence of the ARU do not affect the animal cardiovascular system, giving a proof of concept of its applicability in vivo. (C) 2016 Nalecz Institute of Biocybemetics and Biomedical Engineering of the Polish Academy of Sciences. Published by Elsevier Sp. z o.o. All rights reserved.
引用
收藏
页码:366 / 374
页数:9
相关论文
共 50 条
  • [41] Anticoagulation strategies for left ventricular assist devices
    Toeg, Hadi
    Ruel, Marc
    Haddad, Haissam
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (02) : 192 - 196
  • [42] Anticoagulation management of left ventricular assist devices
    Connors, Jean M.
    AMERICAN JOURNAL OF HEMATOLOGY, 2015, 90 (02) : 175 - 178
  • [43] Implantable Left Ventricular Assist Devices and the Kidney
    Mao, Huijuan
    Katz, Nevin
    Kim, Jeong Chul
    Day, Sonya
    Ronco, Claudio
    BLOOD PURIFICATION, 2014, 37 (01) : 57 - 66
  • [44] Left ventricular assist devices: An ethical analysis
    Katrina A. Bramstedt
    Science and Engineering Ethics, 1999, 5 : 89 - 96
  • [45] Salvaging Exposed Left Ventricular Assist Devices
    White, Aisha
    Kalimuthu, Ramasamy
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (03) : 127E - 129E
  • [46] Percutaneous Deactivation of Left Ventricular Assist Devices
    Albulushi, Arif
    Goldsweig, Andrew M.
    Stoller, Douglas
    Delaney, Jeffrey W.
    Um, John
    Lowes, Brian
    Zolty, Ronald
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (03) : 467 - 472
  • [47] LEFT VENTRICULAR ASSIST DEVICES AND GASTROINTESTINAL BLEEDING
    Islam, S.
    Cevik, C.
    Islam, E.
    Nugent, K.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2011, 59 (02) : 482 - 483
  • [48] Reverse Remodeling With Left Ventricular Assist Devices
    Burkhoff, Daniel
    Topkara, Veli K.
    Sayer, Gabriel
    Uriel, Nir
    CIRCULATION RESEARCH, 2021, 128 (10) : 1594 - 1612
  • [49] MECHANICAL LEFT-VENTRICULAR ASSIST DEVICES
    KRONZON, I
    HAREFUAH, 1977, 93 (3-4) : 105 - 109
  • [50] Left Ventricular Assist Devices: The Authors Reply
    Kostick, Kristin M.
    Blumenthal-Barby, Jennifer
    HEALTH AFFAIRS, 2015, 34 (10)