Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis

被引:30
|
作者
Tiwari, Aseem Kumar [1 ]
Pandey, Prashant [1 ]
Dixit, Surbhi [1 ]
Raina, Vimarsh [2 ,3 ]
机构
[1] Medanta Medicity Hosp, Dept Transfus Med, Gurgaon 122001, Haryana, India
[2] Medanta Medicity Hosp, Lab Serv, Gurgaon 122001, Haryana, India
[3] Medanta Medicity Hosp, Transfus Serv, Gurgaon 122001, Haryana, India
关键词
hemolysis; pneumatic tube system (PTS); supernatant hemoglobin; DELIVERY;
D O I
10.1515/CCLM.2011.779
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The objective of the study was to find the incidence of hemolysis in samples transported through a pneumatic tube system (PTS) at different speeds. Methods: This prospective observational study was done in three phases: "short distance and high speed (115 m at 3 m/s)", "long distance and high speed (225 m at 3 m/s)" and "short distance and slow speed (115 at 2 m/s)". Fifty-two, 215 and 45 serum tube pairs, respectively, were evaluated in these three phases. A set of tubes was sent by PTS while the other was hand-carried. Samples were analyzed for supernatant hemoglobin (Hb), potassium (K+) and lactate dehydrogenase (LD). Results: Mean transit time of samples through the PTS was much shorter as compared to human courier in all three phases. LD was elevated in PTS arm in the "short distance and high speed" phase and in the "long distance and high speed" phase, all three indices of hemolysis - Hb, K+ and LD - showed elevation in the PTS arm. However, at "short distance and slow speed" phase, there was no hemolysis in the PTS arm. Conclusions: Hospitals should validate their PTS before use and, by altering speed of sample transportation, hemolysis may be obliterated.
引用
收藏
页码:471 / 474
页数:4
相关论文
共 40 条
  • [31] EXPERIENCE OF PNEUMATIC TUBE SYSTEM (PTS) FOR TRANSPORTATION OF BLOOD AND BLOOD COMPONENTS AT A TERTIARY CARE REFERRAL ONCOLOGY CENTRE
    Rajadhyaksha, S.
    Malankar, S.
    Desai, P.
    VOX SANGUINIS, 2013, 105 : 81 - 81
  • [32] Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality
    Fernandes, CMB
    Worster, A
    Eva, K
    Hill, S
    McCallum, C
    JOURNAL OF EMERGENCY NURSING, 2006, 32 (02) : 139 - 143
  • [33] EFFECT OF SAMPLE TRANSPORT BY TEMPUS600 PNEUMATIC TUBE SYSTEM ON PLATELETS, PLATELET FUNCTION TESTS AND THROMBOELASTOMETRY
    De Kesel, Pieter
    Devreese, Katrien
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 49 - 49
  • [34] Effects of Transportation of IV Bags Containing Protein Formulations Via Hospital Pneumatic Tube System: Particle Characterization by Multiple Methods
    Linkuviene, Vaida
    Ross, Emma L.
    Crawford, Lindsey
    Weiser, Sarah E.
    Man, Damen
    Kay, Stephen
    Kolhe, Parag
    Carpenter, John F.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 111 (04) : 1024 - 1039
  • [35] The influence of pneumatic tube system vs. manual transport on activation of coagulation measured with thromboelastometry and thrombin generation
    Kuiper, G. J. A. J. M.
    Lance, M. D.
    Sloep, M.
    Spronk, H. M. H.
    van Oerle, R.
    Henkens, Y. M. C.
    Marcus, M. A. E.
    Cate, H. T.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 811 - 811
  • [36] THE PNEUMATIC TUBE SYSTEM IMPROVES SAMPLE TURNAROUND TIME WITHOUT AFFECTING COMPLETE BLOOD COUNT RESULTS: A VALIDATION STUDY AT A TERTIARY CARE HOSPITAL
    Al-Riyami, Arwa Z.
    Al-Khabori, Murtadha
    Al Hadhrami, Rajaa
    Al Azwani, Intisar
    Davis, Heidi
    Al-Farsi, Khalil
    Al-Hunaeini, Mohammed
    Alkindi, Salam
    Daar, Shahina
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 121 - 121
  • [37] Numerical Study on the Influence of the Speed on the Aerodynamic Thermal in the HTS Maglev-Evacuated Tube Transport System
    Wang, Jukun
    Bao, Shijie
    Hu, Xiao
    Li, Haitao
    Deng, Zigang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [38] USE OF A DUAL SAMPLE-BIAXIAL ROTATING ASSEMBLY WITH A PNEUMATIC TUBE TRANSFER SYSTEM FOR HIGH PRECISION 14-MEV NEUTRON ACTIVATION ANALYSIS
    LUNDGREN, FA
    NARGOLWA.SS
    ANALYTICAL CHEMISTRY, 1968, 40 (04) : 672 - &
  • [39] Urgent Delivery - Validation and Operational Implementation of Urgent Blood Delivery by Modern High Speed Hospital Pneumatic Tube System to Support Bleeding Emergencies Within a Hospital Massive Transfusion Protocol
    Chay, Jason Wai Mun
    Kim, Ji Hyun
    Taha, Nur Shahirah B. M.
    Chiew, Siew Hong
    Chin, Kwong Weng
    Lim, Shu Hong
    Ho, Liam Pock
    LABORATORY MEDICINE, 2019, 50 (04) : E59 - E69
  • [40] Effect of primary tube underfilling and hemolysis on PT, APTT, antithrombin and D-Dimer assays; implementing the pre-analytical sample integrity checks of the Sysmex CS-2100i System
    Hoogendoorn, H.
    De Haan, J.
    McGrath, J.
    Ali, E.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 1033 - 1034