Automated finite element meshing of the lumbar spine: Verification and validation with 18 specimen-specific models

被引:42
|
作者
Campbell, J. Q. [1 ,2 ]
Coombs, D. J. [3 ,4 ]
Rao, M. [5 ]
Rullkoetter, P. J. [3 ]
Petrella, A. J. [1 ]
机构
[1] Colorado Sch Mines, Computat Biomech Grp, 1500 Illinois St, Golden, CO 80401 USA
[2] Vector Sci Inc, Golden, CO USA
[3] Univ Denver, Ctr Orthopaed Biomech, Denver, CO 80208 USA
[4] DePuy Synthes Trauma, W Chester, PA USA
[5] BD Med Medicat & Procedural Solut, Franklin Lakes, NJ USA
基金
美国国家科学基金会;
关键词
Lumbar spine; Finite element analysis; Automation; Subject-specific; Validation; SENSITIVITY; LOADS; ROTATION;
D O I
10.1016/j.jbiomech.2016.05.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to seek broad verification and validation of human lumbar spine finite element models created using a previously published automated algorithm. The automated algorithm takes segmented CT scans of lumbar vertebrae, automatically identifies important landmarks and contact surfaces, and creates a finite element model. Mesh convergence was evaluated by examining changes in key output variables in response to mesh density. Semi-direct validation was performed by comparing experimental results for a single specimen to the automated finite element model results for that specimen with calibrated material properties from a prior study. Indirect validation was based on a comparison of results from automated finite element models of 18 individual specimens, all using one set of generalized material properties, to a range of data from the literature. A total of 216 simulations were run and compared to 186 experimental data ranges in all six primary bending modes up to 7.8 Nm with follower loads up to 1000 N. Mesh convergence results showed less than a 5% difference in key variables when the original mesh density was doubled. The semi-direct validation results showed that the automated method produced results comparable to manual finite element modeling methods. The indirect validation results showed a wide range of outcomes due to variations in the geometry alone. The studies showed that the automated models can be used to reliably evaluate lumbar spine biomechanics, specifically within our intended context of use: in pure bending modes, under relatively low non-injurious simulated in vivo loads, to predict torque rotation response, disc pressures, and facet forces. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2669 / 2676
页数:8
相关论文
共 50 条
  • [21] Estimating Facet Joint Apposition with Specimen-Specific Computer Models of Subaxial Cervical Spine Kinematics
    Quarrington, Ryan D.
    Thompson-Bagshaw, Darcy W.
    Jones, Claire F.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (12) : 3200 - 3210
  • [22] Estimating Facet Joint Apposition with Specimen-Specific Computer Models of Subaxial Cervical Spine Kinematics
    Ryan D. Quarrington
    Darcy W. Thompson-Bagshaw
    Claire F. Jones
    Annals of Biomedical Engineering, 2021, 49 : 3200 - 3210
  • [23] Specimen-specific vertebral fracture modeling: a feasibility study using the extended finite element method
    Hugo Giambini
    Xiaoliang Qin
    Dan Dragomir-Daescu
    Kai-Nan An
    Ahmad Nassr
    Medical & Biological Engineering & Computing, 2016, 54 : 583 - 593
  • [24] Specimen-specific vertebral fracture modeling: a feasibility study using the extended finite element method
    Giambini, Hugo
    Qin, Xiaoliang
    Dragomir-Daescu, Dan
    An, Kai-Nan
    Nassr, Ahmad
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) : 583 - 593
  • [25] Specimen-Specific Nonlinear Finite Element Modeling to Predict Vertebrae Fracture Loads After Vertebroplasty
    Matsuura, Y.
    Giambini, H.
    Ogawa, Y.
    Fang, Z.
    Thoreson, A. R.
    Yaszemski, M. J.
    Lu, L.
    An, K. N.
    SPINE, 2014, 39 (22) : E1291 - E1296
  • [26] Quantifying dynamic mechanical properties of human placenta tissue using optimization techniques with specimen-specific finite-element models
    Hu, Jingwen
    Klinich, Kathleen D.
    Miller, Carl S.
    Nazmi, Giseli
    Pearlman, Mark D.
    Schneider, Lawrence W.
    Rupp, Joanthan D.
    JOURNAL OF BIOMECHANICS, 2009, 42 (15) : 2528 - 2534
  • [27] Lumbar spine finite element model for healthy subjects: development and validation
    Xu, Ming
    Yang, James
    Lieberman, Isador H.
    Haddas, Ram
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (01) : 1 - 15
  • [28] Development and validation of a human lumbar spine finite element model based on an automated process: Application to disc degeneration
    Liang, Chang
    Yang, Lei
    Wang, Yuming
    Zhang, Jinyang
    Zhang, Bing
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 105
  • [29] Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material
    Matsuura, Yusuke
    Kuniyoshi, Kazuki
    Suzuki, Takane
    Ogawa, Yasufumi
    Sukegawa, Koji
    Rokkaku, Tomoyuki
    Takahashi, Kazuhisa
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (06) : 1012 - 1018
  • [30] Finite element models more accurately predict structural behavior of human cancellous bone when using specimen-specific tissue properties
    Cole, J. H.
    Myers, E. R.
    van der Meulen, M. C. H.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 : S225 - S225