Laryngoscope and a New Tracheal Tube Assist Lightwand Intubation in Difficult Airways due to Unstable Cervical Spine

被引:19
|
作者
Wu, Cai-neng [1 ]
Ma, Wu-hua [1 ]
Wei, Jian-qi [1 ]
Wei, Hua-feng [2 ]
Cen, Qing-yun [1 ]
Cai, Qing-xiang [1 ]
Cao, Ying [3 ]
机构
[1] Guangzhou Univ Tradit Chinese Med, Affiliated Hosp 1, Dept Anesthesiol, Guangzhou, Guangdong, Peoples R China
[2] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
[3] Southern Med Univ, Sch Pharmacol Sci, Guangzhou, Guangdong, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
LARYNGEAL MASK AIRWAY; LIGHTED STYLET; CLINICAL-TRIAL; MANAGEMENT; TRACHLIGHT(TM); VENTILATION; INSTABILITY; FACILITATE; CHILDREN; PATIENT;
D O I
10.1371/journal.pone.0120231
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The WEI Jet Endotracheal Tube (WEI JET) is a new tracheal tube that facilitates both oxygenation and ventilation during the process of intubation and assists tracheal intubation in patients with difficult airway. We evaluated the effectiveness and usefulness of the WEI JET in combination with lightwand under direct laryngoscopy in difficult tracheal intubation due to unstable cervical spine. Methods Ninety patients with unstable cervical spine disorders (ASA I-III) with general anaesthesia were included and randomly assigned to three groups, based on the device used for intubation: lightwand only, lightwand under direct laryngoscopy, lightwand with WEI JET under direct laryngoscopy. Results No statistically significant differences were detected among three groups with respect to demographic characteristics and C/L grade. There were statistically significant differences between three groups for overall intubation success rate (p = 0.015) and first attempt success rate (p = 0.000). The intubation time was significantly longer in the WEI group (110.8 +/- 18.3 s) than in the LW group (63.3 +/- 27.5 s, p = 0.000) and DL group (66.7 +/- 29.4 s, p = 0.000), but the lowest SpO2 in WEI group was significantly higher than other two groups (p<0.01). The WEI JET significantly reduced successful tracheal intubation attempts compared to the LW group (p = 0.043). The severity of sore throat was similar in three groups (p = 0.185). Conclusions The combined use of WEI JET under direct laryngoscopy helps to assist tracheal intubation and improves oxygenation during intubation in patients with difficult airway secondary to unstable spine disorders.
引用
收藏
页数:9
相关论文
共 41 条