ABC/2 Method Does not Accurately Predict Cerebral Arteriovenous Malformation Volume

被引:12
|
作者
Roark, Christopher [1 ]
Vadlamudi, Venu [2 ]
Chaudhary, Neeraj [3 ]
Gemmete, Joseph J. [3 ]
Seinfeld, Joshua [1 ]
Thompson, B. Gregory [4 ]
Pandey, Aditya S. [4 ]
机构
[1] Univ Colorado, Sch Med, Dept Neurosurg, Aurora, CO USA
[2] Inova Alexandria Hosp, Dept Radiol, Alexandria, VA USA
[3] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Neurosurg, 1500 E Med Ctr Dr,Room 3552 TC, Ann Arbor, MI 48109 USA
关键词
ABC/2; method; Arteriovenous malformation; AVM volume; Cerebral AVM; Planimetric; GAMMA-KNIFE RADIOSURGERY; INTRACEREBRAL HEMORRHAGE; NATURAL-HISTORY; BRAIN; OBLITERATION; HEMATOMA; THERAPY; TRIAL; RATES;
D O I
10.1093/neuros/nyx139
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Stereotactic radiosurgery (SRS) is a treatment option for cerebral arteriovenous malformations (AVMs) to prevent intracranial hemorrhage. The decision to proceed with SRS is usually based on calculated nidal volume. Physicians commonly use the ABC/2 formula, based on digital subtraction angiography (DSA), when counseling patients for SRS. OBJECTIVE: To determine whether AVM volume calculated using the ABC/2 method on DSA is accurate when compared to the exact volume calculated from thin-cut axial sections used for SRS planning. METHODS: Retrospective search of neurovascular database to identify AVMs treated with SRS from 1995 to 2015. Maximum nidal diameters in orthogonal planes on DSA images were recorded to determine volume using ABC/2 formula. Nidal target volume was extracted from operative reports of SRS. Volumes were then compared using descriptive statistics and paired t-tests. RESULTS: Ninety intracranial AVMs were identified. Median volume was 4.96 cm(3) [interquartile range (IQR) 1.79-8.85] with SRS planning methods and 6.07 cm(3) (IQR 1.3-13.6) with ABC/2 methodology. Moderate correlation was seen between SRS and ABC/2 (r = 0.662; P < .001). Paired sample t-tests revealed significant differences between SRS volume and ABC/2 (t = -3.2; P = .002). When AVMs were dichotomized based on ABC/2 volume, significant differences remained (t = 3.1, P = .003 for ABC/2 volume < 7 cm(3); t = -4.4, P < .001 for ABC/2 volume > 7 cm(3)). CONCLUSION: The ABC/2 method overestimates cerebral AVM volume when compared to volumetric analysis from SRS planning software. For AVMs > 7 cm(3), the overestimation is even greater. SRS planning techniques were also significantly different than values derived from equations for cones and cylinders.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 50 条
  • [41] Oxotremorine-induced cerebral hyperemia does not predict infarction volume in spontaneously hypertensive or stroke-prone rats
    Harukuni, I
    Takahashi, H
    Traystman, RJ
    Bhardwaj, A
    Kirsch, JR
    CRITICAL CARE MEDICINE, 2000, 28 (01) : 190 - 195
  • [42] Does Estimated Cardiorespiratory Fitness Accurately Predict Directly Measured Vo2peak In Breast Cancer Survivors?
    Michalski, Meghan
    Capaci, Catherine
    Rowed, Kylie
    Happel, Richard
    Scott, Jessica
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 357 - 357
  • [43] Does effect of a neuroprotective agent on volume of experimental animal cerebral infarct predict effect of the agent on clinical outcome in human stroke?
    Jonas, S
    Tran, AQ
    Eisenberg, E
    Azam, M
    Viera, D
    Grumet, S
    NEUROPROTECTIVE AGENTS - THIRD INTERNATIONAL CONFERENCE, 1997, 825 : 281 - 287
  • [44] ACCURACY OF INTRACEREBRAL HEMORRHAGE VOLUME CALCULATION: COMPARISON BETWEEN A FULLY AUTOMATIC COMPUTERISED METHOD, ABC/2 and sABC/2
    Purcaru, L.
    Radu, R. A.
    Terecoasa, E.
    Tiu, C.
    Marinescu, A. V.
    EUROPEAN JOURNAL OF NEUROLOGY, 2020, 27 : 1037 - 1037
  • [45] NORMAL TISSUE COMPLICATION PROBABILITY ESTIMATION BY THE LYMAN-KUTCHER-BURMAN METHOD DOES NOT ACCURATELY PREDICT SPINAL CORD TOLERANCE TO STEREOTACTIC RADIOSURGERY
    Daly, Megan E.
    Luxton, Gary
    Choi, Clara Y. H.
    Gibbs, Iris C.
    Chang, Steven D.
    Adler, John R.
    Soltys, Scott G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 2025 - 2032
  • [46] Preliminary results of PET activation study in cerebral arteriovenous malformation (AVM), using C15O2 and 18F-FDG
    Itosaka, H
    Kuroda, S
    Houkin, K
    Abe, H
    Shiga, S
    Tamaki, N
    NEUROLOGICAL SURGERY, 2001, 29 (01): : 45 - 50
  • [47] Assessment of the ABC/2 Method of Epidural Hematoma Volume Measurement as Compared to Computer-Assisted Planimetric Analysis
    Hu, Ting-Ting
    Yan, Ling
    Yan, Peng-Fei
    Wang, Xuan
    Yue, Ge-Fen
    BIOLOGICAL RESEARCH FOR NURSING, 2016, 18 (01) : 5 - 11
  • [48] Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?
    Marlies Wagner
    Yiannis Kyriakou
    Richard du Mesnil de Rochemont
    Oliver C. Singer
    Joachim Berkefeld
    CardioVascular and Interventional Radiology, 2013, 36 : 1132 - 1138
  • [49] Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?
    Wagner, Marlies
    Kyriakou, Yiannis
    de Rochemont, Richard du Mesnil
    Singer, Oliver C.
    Berkefeld, Joachim
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (04) : 1132 - 1138
  • [50] Glycated haemoglobin does not accurately predict average capillary glucose in non insulin-treated type 2 diabetes: The PRISMA study experience
    Trevisan, R.
    Bonizzoni, E.
    Bosi, E.
    Ceriello, A.
    Cucinotta, D.
    Giorgino, F.
    Tiengo, A.
    Scavini, M.
    NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2016, 26 (02) : 169 - 170