High-Resolution Multi-Channel Frequency Standard Comparator Using Digital Frequency Measurement

被引:4
|
作者
Xiao, Bo [1 ,2 ,3 ]
Liu, Ya [1 ,2 ,3 ]
Li, Xiaohui [1 ,2 ,3 ]
Deng, Zhifeng [1 ,2 ,3 ]
Xue, Yanrong [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Natl Time Serv Ctr, East Shu Yuan Rd, Xian 710600, Peoples R China
[2] Chinese Acad Sci, Key Lab Time & Frequency Primary Stand, Xian 710600, Peoples R China
[3] Univ Chinese Acad Sci, Sch Astron & Space Sci, Yu Quan Rd, Beijing 100049, Peoples R China
关键词
multichannel; frequency standard comparison; digital frequency measurement;
D O I
10.3390/s21165626
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapid improvement accuracy of the atomic frequency standard puts forward higher requirements for the measurement resolution of the atomic frequency standard comparison system. To overcome the defect that the single zero-crossing point detection is sensitive to noise in the traditional dual mixer time difference measurement method, a digital frequency measurement method is proposed. This method combines sinusoidal beat technology, multi-channel synchronous acquisition technology, and digital frequency measurement technology, and uses differential compensation of system error to realize the precision measurement of atomic frequency standard. The frequency measurement accuracy is less than 2.5 x 10(-14) and the noise floor is better than 6.5 x 10(-15)/tau = 1 s. The system has a high frequency measurement accuracy and a low noise floor, which can realize the precise measurement of a highly stable frequency source.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Multi-Channel Beat-Frequency Digital Measurement System for Frequency Standard
    Liu, Ya
    Li, Xiao-Hui
    Wang, Yu-Lan
    [J]. 2009 JOINT MEETING OF THE EUROPEAN FREQUENCY AND TIME FORUM AND THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2, 2009, : 679 - 684
  • [2] Optimal measurement of frequency instability in a multi-channel comparator
    I. N. Chernyshev
    K. G. Mishagin
    [J]. Measurement Techniques, 2009, 52 : 931 - 939
  • [3] OPTIMAL MEASUREMENT OF FREQUENCY INSTABILITY IN A MULTI-CHANNEL COMPARATOR
    Chernyshev, I. N.
    Mishagin, K. G.
    [J]. MEASUREMENT TECHNIQUES, 2009, 52 (09) : 931 - 939
  • [4] High-resolution frequency standard comparator based on a special phase comparison approach
    Zhou, H
    Zhou, W
    Xuan, ZQ
    Wang, H
    Liu, CS
    [J]. PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, 2005, : 689 - 692
  • [5] Quick measurement of signal frequency in multi-channel
    Lin, H
    Wang, J
    Huang, YQ
    Hu, TL
    [J]. ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 116 - 119
  • [6] A High Precision Proton Magnetometer Based on a Multi-Channel Frequency Measurement
    Liu, Huan
    Dong, Haobin
    Ge, Jian
    Bai, Bingjie
    [J]. 2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 837 - 841
  • [7] High-Resolution Frequency Detection with Multiple AWGs and Post-Processing for Multi-Channel Fiber Sensors
    Takahashi, Kazuto
    Kishikawa, Hiroki
    Goto, Nobuo
    Yu, Yi-Lin
    Liaw, Shien-Kuei
    [J]. 2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [8] A high speed direct digital frequency synthesizer based on multi-channel structure
    袁凌
    张强
    石寅
    [J]. Journal of Semiconductors, 2015, (06) : 135 - 139
  • [9] A high speed direct digital frequency synthesizer based on multi-channel structure
    Ling, Yuan
    Qiang, Zhang
    Yin, Shi
    [J]. JOURNAL OF SEMICONDUCTORS, 2015, 36 (06)
  • [10] A high speed direct digital frequency synthesizer based on multi-channel structure
    袁凌
    张强
    石寅
    [J]. Journal of Semiconductors., 2015, 36 (06) - 139