Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents In Vivo Assessment With Optical Coherence Tomography

被引:107
|
作者
Gutierrez-Chico, Juan Luis [1 ]
Regar, Evelyn [1 ]
Nueesch, Eveline [2 ,3 ]
Okamura, Takayuki [1 ]
Wykrzykowska, Joanna [1 ]
di Mario, Carlo [4 ]
Windecker, Stephan [5 ]
van Es, Gerrit-Anne [6 ]
Gobbens, Pierre [6 ]
Jueni, Peter [2 ,3 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
[3] Univ Hosp Bern, CTU Bern, CH-3010 Bern, Switzerland
[4] Royal Brompton Hosp, London SW3 6LY, England
[5] Univ Bern, Inselspital, Schweizer Herzzentrum, CH-3010 Bern, Switzerland
[6] Cardialysis BV, Rotterdam, Netherlands
关键词
drug eluting stent; malapposition; neointima; optical coherence tomography; INTRAVASCULAR ULTRASOUND FINDINGS; VESSEL WALL RESPONSE; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; BIFURCATION LESIONS; DURABLE POLYMER; THROMBOSIS; IMPLANTATION; PACLITAXEL; APPOSITION;
D O I
10.1161/CIRCULATIONAHA.110.014514
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results-Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I-2=38.40) but not in the other comparisons. Conclusions-Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography.
引用
收藏
页码:612 / U192
页数:21
相关论文
共 50 条
  • [31] Neointimal Coverage on the Stent Struts across Ostia of Aretrial Branches Differs in the Vessel Size of the Side Branch: An Optical Coherence Tomography Study
    Mizukoshi, Masato
    Imanishi, Toshio
    Tanaka, Atsushi
    Kubo, Takashi
    Hirata, Kumiko
    Takarada, Shigeho
    Kitabata, Hironori
    Ino, Yasushi
    Tanimoto, Takashi
    Komukai, Kenichi
    Kuroi, Akio
    Satogami, Keisuke
    Ikejima, Hideyuki
    Kashiwagi, Manabu
    Tsujioka, Hiroto
    Matsumoto, Hiroki
    Ozaki, Yuichi
    Wada, Nozomi
    Nishiguchi, Tsuyoshi
    Masuno, Tomizou
    Maniwa, Naoki
    Teraguchi, Ikuko
    Liu, Yong
    Akasaka, Takashi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 57D - 57D
  • [32] Fate of Side-Branch Jailing and a Malapposed Platinum Marker After Resorption of an Everolimus-Eluting Bioresorbable Vascular Scaffold Serial Optical Coherence Tomography Observations
    Karanasos, Antonios
    Garcia-Garcia, Hector M.
    van Geuns, Robert-Jan
    Regar, Evelyn
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (03) : E53 - E54
  • [33] SERIAL CHANGES OF NEOINTIMAL COVERAGE CHARACTERISTICS IN 4 KINDS OF DRUG-ELUTING STENTS: OPTICAL COHERENCE TOMOGRAPHY STUDY
    Nakamura, Daisuke
    Nishino, Masami
    Yoshimura, Takahiro
    Lee, Yasuharu
    Taniike, Masayuki
    Kato, Hiroyasu
    Egami, Yasuyuki
    Tanouchi, Jun
    Yamada, Yoshio
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E121 - E121
  • [34] Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents
    Guagliumi, Giulio
    Musumeci, Giuseppe
    Sirbu, Vasile
    Bezerra, Hiram G.
    Suzuki, Nobuaki
    Fiocca, Luigi
    Matiashvili, Aleksandre
    Lortkipanidze, Nikoloz
    Trivisonno, Antonio
    Valsecchi, Orazio
    Biondi-Zoccai, Giuseppe
    Costa, Marco A.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) : 531 - 539
  • [35] Assessment of the stent struts across a side branch by optical coherence tomography: comparison among bare-metal stent, sirolimus-eluting stent and paclitaxel-eluting stent
    Liu, Y.
    Mizukoshi, M.
    Tanaka, A.
    Takarada, S.
    Kitabata, H.
    Tanimoto, T.
    Kuroi, A.
    Ikejima, H.
    Imanishi, T.
    Akasaka, T.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 669 - 669
  • [36] A time-course analysis of neointimal growth on the Sirolimus-Eluting Stent struts crossing a side branch using optical coherence tomography
    Terashima, Mitsuyasu
    Ito, Tatsuya
    Takeda, Yoshihiro
    Surmely, Jean-Francois
    Katoh, Osamu
    Matsubara, Tetsuo
    Tsuchikane, Etsuo
    Ehara, Mariko
    Kinoshita, Yoshihisa
    Nasu, Kenya
    Tanaka, Nobuyoshi
    Murata, Akira
    Suzuki, Takahiko
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 96M - 97M
  • [37] NEOINTIMAL COVERAGE OF JAILED STRUT FOLLOWING SINGLE STENTING TO BIFURCATION: OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT FOR 3 TYPES OF DRUG-ELUTING STENTS
    Hariki, Hirotoshi
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Hirata, Ken-ichi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E89 - E89
  • [38] Determinants and Long-Term Outcomes of Largely Uncovered Struts in Thin-Strut Drug-Eluting Stents Assessed by Optical Coherence Tomography: A TRANSFORM-OCT Substudy
    Moretti, Francesco
    Bernelli, Chiara
    Pellegrini, Dario
    Boccuzzi, Giacomo
    Colombo, Francesco
    Sirbu, Vasile
    Vassileva, Angelina
    Fiocca, Luigi
    Canova, Paolo
    Pereira, Gabriel Tensol Rodrigues
    Cereda, Alberto
    De Luca, Leonardo
    Kim, Jung-Sun
    Saia, Francesco
    Capodanno, Davide
    Guagliumi, Giulio
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B179 - B179
  • [39] Tissue coverage and neointimal hyperplasia in overlap versus nonoverlap segments of drug-eluting stents 9 to 13 months after implantation: In vivo assessment with optical coherence tomography
    Gutierrez-Chico, Juan Luis
    Raeber, Lorenz
    Regar, Evelyn
    Okamura, Takayuki
    di Mario, Carlo
    van Es, Gerrit-Anne
    Windecker, Stephan
    Serruys, Patrick W.
    [J]. AMERICAN HEART JOURNAL, 2013, 166 (01) : 83 - +
  • [40] OPTICAL COHERENCE TOMOGRAPHY ACCURATELY DETERMINES NEOINTIMAL COVERAGE AND STENT AREA OF BARE METAL AND DRUG-ELUTING CORONARY STENTS
    Mills, James S.
    Stack-N'diaye, Colleen
    Povsic, Thomas
    Yow, Eric
    Urtz, Mark
    Greenfield, Joseph
    Phillips, Harry
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1743 - E1743