Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents In Vivo Assessment With Optical Coherence Tomography

被引:107
|
作者
Gutierrez-Chico, Juan Luis [1 ]
Regar, Evelyn [1 ]
Nueesch, Eveline [2 ,3 ]
Okamura, Takayuki [1 ]
Wykrzykowska, Joanna [1 ]
di Mario, Carlo [4 ]
Windecker, Stephan [5 ]
van Es, Gerrit-Anne [6 ]
Gobbens, Pierre [6 ]
Jueni, Peter [2 ,3 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
[3] Univ Hosp Bern, CTU Bern, CH-3010 Bern, Switzerland
[4] Royal Brompton Hosp, London SW3 6LY, England
[5] Univ Bern, Inselspital, Schweizer Herzzentrum, CH-3010 Bern, Switzerland
[6] Cardialysis BV, Rotterdam, Netherlands
关键词
drug eluting stent; malapposition; neointima; optical coherence tomography; INTRAVASCULAR ULTRASOUND FINDINGS; VESSEL WALL RESPONSE; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; BIFURCATION LESIONS; DURABLE POLYMER; THROMBOSIS; IMPLANTATION; PACLITAXEL; APPOSITION;
D O I
10.1161/CIRCULATIONAHA.110.014514
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results-Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I-2=38.40) but not in the other comparisons. Conclusions-Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography.
引用
收藏
页码:612 / U192
页数:21
相关论文
共 50 条
  • [1] Delayed coverage in malapposed and side-branch struts with respect to well-apposed struts in drug-eluting stents: in vivo-assessment with optical coherence tomography
    Gutierrez-Chico, J. L.
    Regar, E.
    Nueesch, E.
    Okamura, T.
    Wykrzykowska, J.
    Di Mario, C.
    Windecker, S.
    Van Es, G. A.
    Jueni, P.
    Serruys, P. W.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 407 - 407
  • [2] Response to Letter Regarding Article, "Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents: In Vivo Assessment With Optical Coherence Tomography"
    Gutierrez-Chico, Juan Luis
    Regar, Evelyn
    Okamura, Takayuki
    Wykrzykowska, Joanna
    Serruys, Patrick W.
    Nuesch, Eveline
    Jueni, Peter
    di Mario, Carlo
    Windecker, Stephan
    van Es, Gerrit-Anne
    Gobbens, Pierre
    [J]. CIRCULATION, 2012, 125 (10) : E459 - E459
  • [3] Letter by Perez de Prado et al Regarding Article, "Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents: In Vivo Assessment With Optical Coherence Tomography"
    Perez de Prado, Armando
    Cuellas-Ramon, Carlos
    Fernandez-Vazquez, Felipe
    [J]. CIRCULATION, 2012, 125 (10) : E458 - E458
  • [4] Malapposed struts in drug-eluting stents entail higher risk of incomplete tissue coverage at 9-13 months compared to well-apposed struts: in-vivo demonstration with optical coherence tomography
    Gutierrez-Chico, J. L.
    Regar, E.
    Juni, P.
    Garcia-Garcia, H.
    Kelbaek, H.
    Macaya, C.
    Silber, S.
    Di Mario, C.
    Windecker, S.
    Serruys, P. W.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 72 - 72
  • [5] Neointimal Coverage on Drug-Eluting Stent Struts Crossing Side-Branch Vessels Using Optical Coherence Tomography
    Her, Ae-Young
    Lee, Byoung Kwon
    Shim, Jae-Min
    Kim, Jung-Sun
    Kim, Byoung-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (11): : 1565 - 1569
  • [6] NEOINTIMAL COVERAGE ON THE DRUG-ELUTING STENT STRUTS CROSSING THE SIDE-BRANCH VESSELS : AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Her, Ae-Young
    Hong, Myeong-Ki
    Shim, Jae-Min
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [7] THE CHANGE OF NEOINTIMAL COVERAGE ON DRUG-ELUTING STENT STRUTS CROSSING SIDE-BRANCH VESSELS USING SERIAL OPTICAL COHERENCE TOMOGRAPHY
    Lee, Seung-Yul
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yang Soo
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E149 - E149
  • [8] Neointimal coverage on everolimus-eluting stent struts crossing side-branch vessels compared with first generation drug-eluting stents: an optical coherence tomography analysis
    Nasu, K.
    Kurita, T.
    Ko, E.
    Yokota, D.
    Ito, T.
    Habara, M.
    Kinoshita, Y.
    Terashima, M.
    Suzuki, T.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 403 - 403
  • [9] Assessment by Optical Coherence Tomography of Stent Struts Across Side Branch - Comparison of Bare-Metal Stents and Drug-Eluting Stents
    Liu, Yong
    Imanishi, Toshio
    Kubo, Takashi
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Ino, Yasushi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Komukai, Kenichi
    Ishibashi, Kohei
    Kashiwagi, Manabu
    Ozaki, Yuichi
    Hirata, Kumiko
    Mizukoshi, Masato
    Akasaka, Takashi
    [J]. CIRCULATION JOURNAL, 2011, 75 (01) : 106 - 112
  • [10] Optical Coherence Tomography Assessment of Neointimal Coverage According to the Presence Or Absence Of Malapposed Struts After Drug-eluting Stent Implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B184 - B184