DC-link current estimation for load-side converter of brushless doubly-fed generator in the current feed-forward control

被引:15
|
作者
Wang, Xingwei [1 ]
Lin, Hua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan, Peoples R China
关键词
brushless machines; electric current control; machine control; AC-DC power convertors; PWM power convertors; voltage control; stability; DC generators; load-side converter; brushless doubly-fed generator; current feed-forward control; BDFG control system; back-to-back converter; machine-side converter; MSC; LSC; three-phase AC-DC pulse width modulation converter; double-loop control strategy; outer voltage loop; inner current loop; load disturbance; complex harmonic spectrum; DC-link current estimation algorithm; equivalent circuit; CONTROL SCHEME; PWM CONVERTER; EQUIVALENT-CIRCUIT; INVERTER SYSTEM; FED MACHINES; PERFORMANCE; RECTIFIER; MODEL; CAPACITOR;
D O I
10.1049/iet-pel.2015.0910
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the stand-alone brushless doubly-fed generator (BDFG) control system, there are two back-to-back converters composed of the machine-side converter (MSC) and the load-side converter (LSC). The LSC is a three-phase AC-DC pulse width modulation converter which usually adopts the double-loop control strategy with outer voltage loop and inner current loop. The introduction of the DC-link current feed-forward for improving the dynamic performance of the LSC can reduce the effect of the load disturbance to the system. However, the DC-link current has a complex harmonic spectrum with the MSC connected to the DC side, so its average value is not convenient to measure. This study presents a DC-link current estimation algorithm for the current feed-forward control in the LSC of the stand-alone BDFG. With the help of the equivalent circuit of the BDFG and the power balance, the rapid calculation of the average DC-link current can be estimated as well. With this estimation of the current instead of the actual DC-link current, the DC-link voltage and AC side current of the LSC can achieve stability quickly. The effectiveness and correction is validated by the simulation and experiments.
引用
收藏
页码:1703 / 1710
页数:8
相关论文
共 50 条
  • [41] Phase Current Estimation of BLDC Motor Drive System by Using Source Side Current of DC-Link
    Moon, Jong-Joo
    Park, Je-Wook
    Kim, Jang-Mok
    Hwang, Seon-Hwan
    Bang, Deok-Je
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 1270 - 1275
  • [42] A Modified DC Chopper for Limiting the Fault Current and Controlling the DC-Link Voltage to Enhance Fault Ride-Through Capability of Doubly-Fed Induction-Generator-Based Wind Turbine
    Naderi, Seyed Behzad
    Negnevitsky, Michael
    Muttaqi, Kashem M.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (02) : 2021 - 2032
  • [43] Flexible Control of DC-link Voltage for Doubly Fed Induction Generator during Grid Voltage Swell
    Liu, Changjin
    Huang, Xiaobo
    Chen, Min
    Xu, Dehong
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 3091 - 3095
  • [44] An improved control strategy of limiting the dc-link voltage fluctuation for a doubly fed induction wind generator
    Yao, Jun
    Li, Hui
    Liao, Yong
    Chen, Zhe
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) : 1205 - 1213
  • [45] A New Vector Control of Brushless Doubly-Fed Induction Generator With Transient Current Compensation for Stand-Alone Power Generation Applications
    Liu, Yi
    Xu, Wei
    Yu, Kailiang
    Blaabjerg, Frede
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 1392 - 1398
  • [46] Research on Short Circuit Current Characteristics of Doubly-fed Wind Power Generator Considering Converter Regulation
    Ma, Jing
    Zhang, Weibo
    Liu, Jing
    Thorp, James S.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (19) : 2118 - 2130
  • [47] Observer-Based DC Voltage Droop and Current Feed-Forward Control of a DC Microgrid
    Li, Xialin
    Guo, Li
    Zhang, Shaohui
    Wang, Chengshan
    Li, Yun Wei
    Chen, Anwei
    Feng, Yibin
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (05) : 5207 - 5216
  • [48] Design and Implementation of Current based Vector Control Model of Brushless Doubly Fed Induction Generator
    Moghaddam, F. Khazaeli
    Gorginpour, H.
    Hajbabaei, A.
    Ouni, S.
    Oraee, H.
    2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [49] Improved Current Control Structure for the Brushless Doubly-Fed Machine Based on a New Equivalent Circuit Model
    Loehdefink, Philipp
    Dietz, Armin
    Moeckel, Andreas
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 1551 - 1557
  • [50] Stator-Current-Based MRAS Observer for the Sensorless Control of the Brushless Doubly-Fed Induction Machine
    Zhang, Guanguan
    Yang, Jian
    Su, Mei
    Tang, Weiyi
    Blaabjerg, Frede
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 3150 - 3155