DC-link current estimation for load-side converter of brushless doubly-fed generator in the current feed-forward control

被引:15
|
作者
Wang, Xingwei [1 ]
Lin, Hua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan, Peoples R China
关键词
brushless machines; electric current control; machine control; AC-DC power convertors; PWM power convertors; voltage control; stability; DC generators; load-side converter; brushless doubly-fed generator; current feed-forward control; BDFG control system; back-to-back converter; machine-side converter; MSC; LSC; three-phase AC-DC pulse width modulation converter; double-loop control strategy; outer voltage loop; inner current loop; load disturbance; complex harmonic spectrum; DC-link current estimation algorithm; equivalent circuit; CONTROL SCHEME; PWM CONVERTER; EQUIVALENT-CIRCUIT; INVERTER SYSTEM; FED MACHINES; PERFORMANCE; RECTIFIER; MODEL; CAPACITOR;
D O I
10.1049/iet-pel.2015.0910
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the stand-alone brushless doubly-fed generator (BDFG) control system, there are two back-to-back converters composed of the machine-side converter (MSC) and the load-side converter (LSC). The LSC is a three-phase AC-DC pulse width modulation converter which usually adopts the double-loop control strategy with outer voltage loop and inner current loop. The introduction of the DC-link current feed-forward for improving the dynamic performance of the LSC can reduce the effect of the load disturbance to the system. However, the DC-link current has a complex harmonic spectrum with the MSC connected to the DC side, so its average value is not convenient to measure. This study presents a DC-link current estimation algorithm for the current feed-forward control in the LSC of the stand-alone BDFG. With the help of the equivalent circuit of the BDFG and the power balance, the rapid calculation of the average DC-link current can be estimated as well. With this estimation of the current instead of the actual DC-link current, the DC-link voltage and AC side current of the LSC can achieve stability quickly. The effectiveness and correction is validated by the simulation and experiments.
引用
收藏
页码:1703 / 1710
页数:8
相关论文
共 50 条
  • [1] A transient reactive current compensation strategy for load-side converters of brushless doubly-fed generator in stand-alone operation
    Wang Z.
    Lin H.
    Wang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2016, 36 (15): : 4242 - 4248
  • [2] Brushless Doubly-Fed Induction Machine with Feed-Forward Torque Compensation Control
    Mehrjardi, Ramin Tafazzoli
    Ershad, Nima Farrokhzad
    Rahrovi, Babak
    Ehsani, Mehrdad
    2021 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2021, : 53 - 58
  • [3] Digital load current feed-forward control method for a dc-dc converter
    Chae, S. Y.
    Hyun, B. C.
    Kim, W. S.
    Cho, B. H.
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 498 - 502
  • [4] Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
    Morawiec, Marcin
    Kroplewski, Pawel
    Wilczynski, Filip
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (08) : 9055 - 9066
  • [5] Application of the DC-Link Current Sensors of the Back-to-Back Converters for the Operation of a Doubly-Fed Induction Generator
    Suwan-ngam, W.
    Khomfoi, S.
    2015 18TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2015, : 698 - 704
  • [6] Transient Control of the Reactive Current for the Line-Side Converter of the Brushless Doubly-Fed Induction Generator in Stand-Alone Operation
    Wang, Xingwei
    Lin, Hua
    Wang, Zhe
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (10) : 8193 - 8203
  • [7] Direct capacitance current control strategy of dc-link voltage for doubly-fed wind power generation
    Gao S.
    Cui J.
    Hu T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (08): : 152 - 158
  • [8] Control of a Brushless Doubly-Fed Induction Generator via a Matrix Converter
    Sureda, Alvaro
    Munoz, Andres
    Pena, Ruben
    Cardenas, Roberto
    Clare, Jon
    Wheeler, Pat
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [9] Dynamic modeling of a dual active bridge DC to DC converter with average current control and load-current feed-forward
    Guacaneme, Javier
    Garcera, Gabriel
    Figueres, Emilio
    Patrao, Ivan
    Gonzalez-Medina, Raul
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2015, 43 (10) : 1311 - 1332
  • [10] Research on current loop decoupling control of Brushless doubly-fed machine
    Wang, Nannan