Higher-order aberration analysis in symmetry-free optical systems

被引:0
|
作者
Tang, Z. [1 ]
Gross, H. [1 ,2 ]
机构
[1] Friedrich Schiller Univ Jena, Inst Appl Phys, Albert Einstein Str 15, D-07745 Jena, Germany
[2] Fraunhofer Inst Appl Opt & Precis Engn IOF, Albert Einstein Str 7, D-07745 Jena, Germany
来源
关键词
Full-order transverse aberration; surface contribution; intrinsic/induced aberration; Zernike coefficient;
D O I
10.1117/12.2596127
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Compared to the rotationally symmetric systems, the surface-decomposed aberrations of the symmetry-free system is harder for analysis, due to the invalidity of the conventional paraxial reference. To solve this problem, a novel higher-order aberration calculation method for symmetry-free systems is proposed based on the mixed ray-tracing method, which is proved as a good approximation of the full-order transverse aberration for generalized systems. Furthermore, the method is also applicable for intrinsic/induced aberration calculation, as well as the surface additive Zernike coefficient fitting. With various potential implementations, the method is considered a convenient and powerful tool for aberration analysis of offaxis systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Anti-symmetry of higher-order subtyping
    Compagnoni, A
    Goguen, H
    COMPUTER SCIENCE LOGIC, PROCEEDINGS, 1999, 1683 : 420 - 438
  • [22] SYMMETRY AND QUANTIZATION - HIGHER-ORDER POLARIZATION AND ANOMALIES
    ALDAYA, V
    NAVARROSALAS, J
    BISQUERT, J
    LOLL, R
    JOURNAL OF MATHEMATICAL PHYSICS, 1992, 33 (09) : 3087 - 3097
  • [23] Comparison of higher-order aberration and optical quality after Epi-LASIK and LASIK for myopia
    Xiaoyan Yang
    Yan Wang
    Kanxing Zhao
    Lihua Fang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 281 - 288
  • [24] Comparison of higher-order aberration and optical quality after Epi-LASIK and LASIK for myopia
    Yang, Xiaoyan
    Wang, Yan
    Zhao, Kanxing
    Fang, Lihua
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (02) : 281 - 288
  • [25] DIGITAL SYSTEMS OF HIGHER-ORDER
    SCHEUING, EU
    SPERLICH, J
    1978, 51 (4-5): : 185 - 190
  • [26] HIGHER-ORDER PCM SYSTEMS
    SPERLICH, J
    INTERNATIONALE ELEKTRONISCHE RUNDSCHAU, 1974, 28 (01): : 5 - 7
  • [27] HIGHER-ORDER SENSITIVITY ANALYSIS OF COMPLEX, COUPLED SYSTEMS
    SOBIESZCZANSKISOBIESKI, J
    AIAA JOURNAL, 1990, 28 (04) : 756 - 758
  • [28] Corneal higher-order aberrations Cross Mark and higher-order Strehl ratio after aberration-free ablation profile to treat compound myopic astigmatism
    Brenner, Luis F.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12): : 2672 - 2682
  • [29] CANONICAL ABERRATION THEORY FOR CALCULATING HIGHER-ORDER CHROMATIC ABERRATIONS
    XIMEN, JY
    JOURNAL OF APPLIED PHYSICS, 1991, 69 (04) : 1962 - 1967
  • [30] Influence of refractive status and age on corneal higher-order aberration
    Kiuchi, Gaku
    Hiraoka, Takahiro
    Ueno, Yuta
    Mihashi, Toshifumi
    Oshika, Tetsuro
    VISION RESEARCH, 2021, 181 : 32 - 37