Multilayer mirror based soft x-ray spectrometer as a high temperature plasma diagnostic

被引:4
|
作者
Duorah, S [1 ]
Ejiri, A
Lee, S
Iguchi, H
Fujisawa, A
Kojima, M
Matsuoka, K
Ishiyama, E
Hanada, K
Shiraiwa, S
Toyama, H
Takase, Y
机构
[1] Univ Tokyo, Sch Sci, Dept Phys, Tokyo 1130033, Japan
[2] Japan Atom Energy Res Inst, Tsukuba, Ibaraki 3110193, Japan
[3] Natl Inst Fus Sci, Toki 5095292, Japan
[4] Kyushu Univ, RIAM, Adv Fus Res Ctr, Fukuoka 8160811, Japan
[5] Univ Tokyo, Sch Frontier Sci, Dept Complex Sci & Engn, Tokyo 1130033, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2001年 / 72卷 / 01期
关键词
D O I
10.1063/1.1324745
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fully calibrated multilayer mirror (MLM) based soft x-ray spectrometer has been developed and installed on the Compact Helical System (CHS). This MLM based spectrometer is a new approach to devising a soft x-ray spectrometer with medium time and energy resolutions. The spectrometer mainly consists of a MLM as the dispersive element and a 20-channel (p-i-n) pin diode array for the detection of the soft x-rays. Both the MLM and the pin diodes have been calibrated at the KEK (High Energy Accelerator Research Organization) Photon Factory for an energy range of 300-1200 eV. The reflectivity of the mirror was found to increase from 3% (photon energy of 335 eV) to 25% (photon energy of 1050 eV). The pin diodes were found to have almost 100% efficiency for creating electron-hole pairs in the calibrated energy range. The spectrometer was installed on the CHS with the aim of fast electron temperature measurement and study of fast magneto-hydrodynamic (MHD) events occurring in plasmas. The experiments show that in the energy range of measurement, the electron "temperature" determined from the slope of the soft x-ray spectrum is much lower than that measured by the Thomson scattering diagnostic. Analysis showed that the soft x-ray spectrum is highly contaminated by impurity emission. Therefore it may be possible to measure electron temperature with this diagnostic if we choose another energy range where we can measure the continuous spectrum. The present time resolution of the system is of the order similar to0.1 ms, which made it possible to study the behavior of the plasma during fast MHD events. Modulations in the soft x-ray intensity were observed during MHD events in CHS plasmas. Analysis of these shows that these may be due to modulations in the temperature or the impurity concentration. (C) 2001 American Institute of Physics.
引用
收藏
页码:1183 / 1187
页数:5
相关论文
共 50 条
  • [21] PHOTOMULTIPLIER SOFT X-RAY SPECTROMETER
    JACOB, L
    NOBLE, R
    YEE, H
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1960, 37 (12): : 460 - 463
  • [22] Global optimization of two-multilayer mirror objective for focusing soft X-ray high harmonics
    Toyoda, M.
    Yamashita, S.
    Chen, J.
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE VI, 2019, 11032
  • [23] A Design Method of Multilayer Mirror in Soft X Ray Multilayer Mirror and Its Program
    Song Limin
    Yu Hua
    Chi Fengshi
    PROCEEDINGS OF 2ND INTERNATIONAL SYMPOSIUM ON PHYSICS AND HIGH-TECH INDUSTRY, 4TH INTERNATIONAL SYMPOSIUM ON MAGNETIC INDUSTRY, 1ST SHENYANG FORUM FOR DEVELOPMENT AND COOPERATION OF HIGH-TECH INDUSTRY IN NORTHEAST ASIA, 2009, : 302 - 304
  • [24] Calibration of a high resolution grating soft x-ray spectrometer
    Magee, E. W.
    Dunn, J.
    Brown, G. V.
    Cone, K. V.
    Park, J.
    Porter, F. S.
    Kilbourne, C. A.
    Kelley, R. L.
    Beiersdorfer, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [25] Multilayer Soft X-Ray Optics
    Falco, Charles M.
    FIFTY YEARS OF OPTICAL SCIENCES AT THE UNIVERSITY OF ARIZONA, 2014, 9186
  • [26] Soft X-ray multilayer optics
    Salashchenko, N.N.
    Platonov, Yu.Ya.
    Zuev, S.Yu.
    Poverkhnost Rentgenovskie Sinkhronnye i Nejtronnye Issledovaniya, 1995, (09): : 5 - 20
  • [27] Laterally-graded multilayer as x-ray mirror for the laser-induced plasma x-ray sources
    Cheng, Xianchao
    Tan, Bozhong
    Cheng, Jinming
    Liu, Dongbing
    Mu, Jian
    Yang, Qingguo
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XII, 2017, 10386
  • [28] ON THE THEORY OF REFLECTIVITY BY AN X-RAY MULTILAYER MIRROR
    KOHN, VG
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1995, 187 (01): : 61 - 70
  • [29] Development of a multilayer mirror for high-intensity monochromatic x-ray using lab-based x-ray source
    Thanh-Hai Nguyen
    Song, Seonggeun
    Jung, Jin-Ho
    Jeon, Insu
    OPTICS LETTERS, 2012, 37 (18) : 3777 - 3779
  • [30] Feasibility study for a high-k temperature fluctuation diagnostic based on soft x-ray imaging
    Chen, X.
    Ruiz, J. Ruiz
    Howard, N. T.
    Guttenfelder, W.
    Candy, J.
    Hughes, J. W.
    Granetz, R. S.
    White, A. E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):