Multilayer mirror based soft x-ray spectrometer as a high temperature plasma diagnostic

被引:4
|
作者
Duorah, S [1 ]
Ejiri, A
Lee, S
Iguchi, H
Fujisawa, A
Kojima, M
Matsuoka, K
Ishiyama, E
Hanada, K
Shiraiwa, S
Toyama, H
Takase, Y
机构
[1] Univ Tokyo, Sch Sci, Dept Phys, Tokyo 1130033, Japan
[2] Japan Atom Energy Res Inst, Tsukuba, Ibaraki 3110193, Japan
[3] Natl Inst Fus Sci, Toki 5095292, Japan
[4] Kyushu Univ, RIAM, Adv Fus Res Ctr, Fukuoka 8160811, Japan
[5] Univ Tokyo, Sch Frontier Sci, Dept Complex Sci & Engn, Tokyo 1130033, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2001年 / 72卷 / 01期
关键词
D O I
10.1063/1.1324745
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fully calibrated multilayer mirror (MLM) based soft x-ray spectrometer has been developed and installed on the Compact Helical System (CHS). This MLM based spectrometer is a new approach to devising a soft x-ray spectrometer with medium time and energy resolutions. The spectrometer mainly consists of a MLM as the dispersive element and a 20-channel (p-i-n) pin diode array for the detection of the soft x-rays. Both the MLM and the pin diodes have been calibrated at the KEK (High Energy Accelerator Research Organization) Photon Factory for an energy range of 300-1200 eV. The reflectivity of the mirror was found to increase from 3% (photon energy of 335 eV) to 25% (photon energy of 1050 eV). The pin diodes were found to have almost 100% efficiency for creating electron-hole pairs in the calibrated energy range. The spectrometer was installed on the CHS with the aim of fast electron temperature measurement and study of fast magneto-hydrodynamic (MHD) events occurring in plasmas. The experiments show that in the energy range of measurement, the electron "temperature" determined from the slope of the soft x-ray spectrum is much lower than that measured by the Thomson scattering diagnostic. Analysis showed that the soft x-ray spectrum is highly contaminated by impurity emission. Therefore it may be possible to measure electron temperature with this diagnostic if we choose another energy range where we can measure the continuous spectrum. The present time resolution of the system is of the order similar to0.1 ms, which made it possible to study the behavior of the plasma during fast MHD events. Modulations in the soft x-ray intensity were observed during MHD events in CHS plasmas. Analysis of these shows that these may be due to modulations in the temperature or the impurity concentration. (C) 2001 American Institute of Physics.
引用
收藏
页码:1183 / 1187
页数:5
相关论文
共 50 条
  • [1] Multilayer Mirror Based High-Resolution Solar Soft X-Ray Spectrometer
    Panini, S. S.
    Narendranath, S.
    Sreekumar, P.
    Sankarasubramanian, K.
    FRONTIERS IN ASTRONOMY AND SPACE SCIENCES, 2021, 8
  • [2] Multilayer mirror soft x-ray spectrometer for fast electron temperature measurement on the compact helical system
    Lee, S
    Duorah, S
    Ejiri, A
    Iguchi, H
    Fujisawa, A
    Ishiyama, E
    Takase, Y
    Toyama, H
    Aramaki, M
    Kojima, M
    Okamura, S
    Matsuoka, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (04): : 1671 - 1674
  • [3] Multilayer mirror-based soft x-ray polarimeter for astronomical observations
    Panini, Singam S.
    Sreekumar, Parameswaran
    Marshall, Herman L.
    Narendranath, Shyama
    Nayak, Maheswar
    Athiray, P. Subramania
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (01)
  • [4] Calculation of line profile and luminosity of X-ray spectrometer based on multilayer cylindrical mirror
    Lobanova, Yu.L.
    Subbotin, A.N.
    Nagornyi, V.I.
    Gusikhina, I.A.
    Poverkhnost Rentgenovskie Sinkhronnye i Nejtronnye Issledovaniya, 2004, (11): : 5 - 9
  • [5] HIGH THROUGHPUT MULTILAYER MIRROR BASED SOFT-X-RAY SPECTROMETER FOR METALLIC IMPURITY EMISSION FROM TOKAMAKS
    ZWICKER, AP
    REGAN, SP
    FINKENTHAL, M
    MOOS, HW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2786 - 2788
  • [6] Structure design and finite-element analysis of multilayer-mirror soft X-ray energy spectrometer
    Research Center of Laser Fusion, China Acad. of Eng. Phys., P.O.Box 919-986, Mianyang 621900, China
    Qiangjiguang Yu Lizishu, 2008, 8 (1275-1278):
  • [7] A Soft X-ray Spectrometer using a Highly Dispersive Multilayer Grating
    Warwick, Tony
    Padmore, Howard
    Voronov, Dmitriy
    Yashchuk, Valeriy
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 776 - 780
  • [8] Soft X-ray Photon Energy Calibration Using Multilayer Mirror
    Kiranjot
    Sinha, Mangalika
    Gupta, R. K.
    Yadav, P. K.
    Modi, Mohammed H.
    DAE SOLID STATE PHYSICS SYMPOSIUM 2019, 2020, 2265
  • [9] Application of Multilayer Mirror for Harmonic Analysis in Soft X-ray Region
    Modi, Mohammed H.
    Gupta, R. K.
    Lodha, G. S.
    SOLID STATE PHYSICS, PTS 1 AND 2, 2012, 1447 : 507 - 508
  • [10] High resolution solar soft X-ray spectrometer
    张飞
    王焕玉
    彭文溪
    梁晓华
    张春雷
    曹学蕾
    姜维春
    张家宇
    崔兴柱
    中国物理C, 2012, 36 (02) : 146 - 150