Photomask CD and LER characterization using Mueller Matrix Spectroscopic Ellipsometry

被引:2
|
作者
Heinrich, A. [1 ]
Dirnstorfer, I. [1 ]
Bischoff, J. [2 ]
Meiner, K. [3 ]
Ketelsen, H. [3 ]
Richter, U. [3 ]
Mikolajick, T. [1 ,4 ]
机构
[1] NaMLab gGmbH, D-01187 Dresden, Germany
[2] Osires, D-98693 Ilmenau, Germany
[3] Sentech Instruments GmbH, D-12489 Berlin, Germany
[4] Tech Univ Dresden, Inst Semicond & Microsystems, D-01187 Dresden, Germany
关键词
Mueller matrix; spectroscopic ellipsometry; RCWA; photomask; line edge roughness; critical dimension; GRATINGS;
D O I
10.1117/12.2065670
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Critical dimension and line edge roughness on photomask arrays are determined with Mueller matrix spectroscopic ellipsometry. Arrays with large sinusoidal perturbations are measured for different azimuth angels and compared with simulations based on rigorous coupled wave analysis. Experiment and simulation show that line edge roughness leads to characteristic changes in the different Mueller matrix elements. The influence of line edge roughness is interpreted as an increase of isotropic character of the sample. The changes in the Mueller matrix elements are very similar when the arrays are statistically perturbed with rms roughness values in the nanometer range suggesting that the results on the sinusoidal test structures are also relevant for "real" mask errors. Critical dimension errors and line edge roughness have similar impact on the SE MM measurement. To distinguish between both deviations, a strategy based on the calculation of sensitivities and correlation coefficients for all Mueller matrix elements is shown. The Mueller matrix elements M-13/M-31 and M-34/M-43 are the most suitable elements due to their high sensitivities to critical dimension errors and line edge roughness and, at the same time, to a low correlation coefficient between both influences. From the simulated sensitivities, it is estimated that the measurement accuracy has to be in the order of 0.01 and 0.001 for the detection of 1 nm critical dimension error and 1 nm line edge roughness, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Broadband optical properties of graphene and HOPG investigated by spectroscopic Mueller matrix ellipsometry
    Song, Baokun
    Gu, Honggang
    Zhu, Simin
    Jiang, Hao
    Chen, Xiuguo
    Zhang, Chuanwei
    Liu, Shiyuan
    APPLIED SURFACE SCIENCE, 2018, 439 : 1079 - 1087
  • [22] Application of Mueller Matrix Spectroscopic Ellipsometry to determine Line Edge Roughness on Photomasks
    Heinrich, A.
    Dirnstorfer, I.
    Bischoff, J.
    Richter, U.
    Ketelsen, H.
    Meiner, K.
    Mikolajick, T.
    29TH EUROPEAN MASK AND LITHOGRAPHY CONFERENCE, 2013, 8886
  • [23] Optical activity temperature-dependent measurements of chiral solutions using Mueller matrix spectroscopic ellipsometry
    Vala, Daniel
    Micica, Martin
    Postava, Kamil
    Pistora, Jaromir
    21ST CZECH-POLISH-SLOVAK OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2018, 10976
  • [24] Mueller-matrix ellipsometry: a review
    Azzam, RMA
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING, 1997, 3121 : 396 - 405
  • [25] MUELLER MATRIX ANALYSIS OF INFRARED ELLIPSOMETRY
    WOLD, E
    BREMER, J
    APPLIED OPTICS, 1994, 33 (25): : 5982 - 5993
  • [26] MUELLER MATRIX ELLIPSOMETRY WITH IMPERFECT COMPENSATORS
    HAUGE, PS
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (11) : 1519 - 1528
  • [27] Useful Mueller matrix symmetries for ellipsometry
    Arteaga, Oriol
    THIN SOLID FILMS, 2014, 571 : 584 - 588
  • [28] Characterization of Volume Gratings Based on Distributed Dielectric Constant Model Using Mueller Matrix Ellipsometry
    Jiang, Hao
    Ma, Zhao
    Gu, Honggang
    Chen, Xiuguo
    Liu, Shiyuan
    APPLIED SCIENCES-BASEL, 2019, 9 (04):
  • [29] Imaging Mueller matrix ellipsometry for characterization of non-periodic nanostructures
    Kaeseberg, Tim
    Grundmann, Jana
    Siefke, Thomas
    Kroker, Stefanie
    Bodermann, Bernd
    TM-TECHNISCHES MESSEN, 2022, 89 (06) : 438 - 446
  • [30] Fast ellipsometry and Mueller-matrix ellipsometry using the division-of-amplitude photopolarimeter
    Krishnan, S
    Nordine, PC
    INTERNATIONAL SYMPOSIUM ON POLARIZATION ANALYSIS AND APPLICATIONS TO DEVICE TECHNOLOGY, 1996, 2873 : 152 - 156