Blood pressure measurement in epidemiological studies: a comparative analysis of two methods. Data from the EPIC-Potsdam Study

被引:23
|
作者
Kroke, A
Fleischhauer, W
Mieke, S
Klipstein-Grobusch, K
Willich, SN
Boeing, H
机构
[1] German Inst Human Nutr, Dept Epidemiol, D-14558 Bergholz Rehbrucke, Germany
[2] Humboldt Univ, Inst Occupat Med Social Med & Epidemiol, Berlin, Germany
[3] Fed Inst Sci & Technol, Berlin, Germany
关键词
blood pressure measurement; epidemiology; measurement error; sphygmomanometry; automated oscillometry; data comparability;
D O I
10.1097/00004872-199816060-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To investigate the impact of a device replacement in blood pressure measurement in epidemiological studies on comparison and interpretation of epidemiological data by replacing traditional aneroid manometry with automated oscillometric devices. Design Within the context of a continuing epidemiological study (EPIC-Potsdam Study), blood pressure measurements were performed simultaneously with an aneroid sphygmomanometer and an automated oscillometric device for each subject We randomly selected 400 men and women from the main study population and one observer performed three consecutive blood pressure measurements for each subject according to a standardized procedure. In total, 10 oscillometric devices of the same type were used. Demographic and anthropometric data for each subject were obtained by trained interviewers. Results The mean difference between the aneroid and the oscillometric measurements of systolic blood pressure was 0.2 +/- 5.6 mmHg (aneroid value greater, NS), whereas the mean difference in diastolic blood pressure, 0.5 +/- 3.5 mmHg (aneroid value smaller), attained statistical significance (P = 0.0001), Estimates of prevalence for hypertension differed by 0.4% for women, and by 2.9% for men, Associations with the differences between methods were observed with age, blood pressure, lean body mass, upper arm circumference and specific devices without indicating a strong and consistent pattern. Conclusions The use of automated oscillometric devices in epidemiological studies introduces a bias of very small magnitude compared with use of the aneroid method. The effect of the change to this automated measurement procedure on prevalence estimates is small but might affect comparability of data. Minor differences in measurement performance between devices of one type might affect population parameters. (C) 1998 Lippincott-Raven Publishers.
引用
收藏
页码:739 / 746
页数:8
相关论文
共 50 条
  • [21] Use of automated blood pressure measurements in clinical trials and registration studies: data from the VALTOP Study
    Mengden, Thomas
    Asmar, Roland
    Kandra, Albert
    Di Giovanni, Robert
    Brudi, Philip
    Parati, Gianfranco
    BLOOD PRESSURE MONITORING, 2010, 15 (04) : 188 - 194
  • [22] Validation of a Practical Approach to Blood Pressure Measurement: Secondary Analysis of Data from a Nationally Representative Survey in India
    Shivashankar, Roopa
    Sharma, Bhawna
    Moran, Andrew E.
    Pathni, Anupam Khungar
    GLOBAL HEART, 2021, 16 (01)
  • [23] Patient Experiences With Blood Pressure Measurement Methods for Hypertension Diagnosis: Qualitative Findings From the BP-CHECK Study
    Hansell, Laurel D.
    Hsu, Clarissa W.
    Munson, Sean A.
    Margolis, Karen L.
    Thompson, Matthew J.
    Ehrlich, Kelly J.
    Hall, Yoshio N.
    Anderson, Melissa L.
    Evers, Sarah C.
    Marcus-Smith, Miriam S.
    McClure, Jennifer B.
    Green, Beverly B.
    AMERICAN JOURNAL OF HYPERTENSION, 2024, 37 (11) : 868 - 875
  • [24] Data on prevalence of hypertension and blood pressure in Turkey: Systematic review, meta-analysis and meta-regression of epidemiological studies on cardiovascular risk factors
    Kilickap, Mustafa
    Barcin, Cem
    Goksuluk, Huseyin
    Karaaslan, Doruk
    Ozer, Necla
    Kayikcioglu, Meral
    Ural, Dilek
    Yilmaz, Mehmet Birhan
    Abaci, Adnan
    Arici, Mustafa
    Altun, Bulent
    Tokgozoglu, Lale
    Sahin, Mahmut
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (07): : 525 - 545
  • [25] Neighbourhood socioeconomic characteristics and blood pressure among Jamaican youth: a pooled analysis of data from observational studies
    Ferguson, Trevor S.
    Younger-Coleman, Novie O. M.
    Mullings, Jasneth
    Francis, Damian
    Greene, Lisa-Gaye
    Lyew-Ayee, Parris
    Wilks, Rainford
    PEERJ, 2020, 8
  • [26] Detection of masked hypertension by home blood pressure measurement: Is the number of measurements an important issue? Data from the SHEAF study
    Mallion, JM
    Genes, N
    Clerson, P
    Vaur, L
    Vaisse, B
    Bobrie, G
    Chatellier, G
    JOURNAL OF HYPERTENSION, 2004, 22 : S137 - S138
  • [27] Association of low blood pressure and falls: An analysis of data from the Leiden 85-plus Study
    Rothlisberger, David
    Jungo, Katharina Tabea
    Buetikofer, Lukas
    Poortvliet, Rosalinde K. E.
    Gussekloo, Jacobijn
    Streit, Sven
    PLOS ONE, 2023, 18 (12):
  • [28] Population pharmacokinetic analysis of blood robenacoxib data from two dose confirmation field studies in dogs with osteoarthritis
    Giraudel, J. M.
    Peyrou, M.
    King, J. N.
    Gruet, P.
    JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 2009, 32 : 102 - 103
  • [29] Description of two waterborne disease outbreaks in France: a comparative study with data from cohort studies and from health administrative databases
    Mouly, D.
    Van Cauteren, D.
    Vincent, N.
    Vaissiere, E.
    Beaudeau, P.
    Ducrot, C.
    Gallay, A.
    EPIDEMIOLOGY AND INFECTION, 2016, 144 (03): : 591 - 601
  • [30] TWO SIMPLE METHODS OF MEASURING ADHERENCE IN HYPERTENSIVE PATIENTS ARE PREDICTIVE OF BLOOD PRESSURE CONTROL: POOLED ANALYSIS OF 17,516 PATIENTS FROM SEVEN VALSARTAN STUDIES
    Villa, L.
    MacDonald, K.
    Denhaerynck, K.
    Sun, D.
    Vancayzeele, S.
    Brie, H.
    Aerts, A.
    Abraham, I
    VALUE IN HEALTH, 2013, 16 (07) : A532 - A532