Blood pressure measurement in epidemiological studies: a comparative analysis of two methods. Data from the EPIC-Potsdam Study

被引:23
|
作者
Kroke, A
Fleischhauer, W
Mieke, S
Klipstein-Grobusch, K
Willich, SN
Boeing, H
机构
[1] German Inst Human Nutr, Dept Epidemiol, D-14558 Bergholz Rehbrucke, Germany
[2] Humboldt Univ, Inst Occupat Med Social Med & Epidemiol, Berlin, Germany
[3] Fed Inst Sci & Technol, Berlin, Germany
关键词
blood pressure measurement; epidemiology; measurement error; sphygmomanometry; automated oscillometry; data comparability;
D O I
10.1097/00004872-199816060-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To investigate the impact of a device replacement in blood pressure measurement in epidemiological studies on comparison and interpretation of epidemiological data by replacing traditional aneroid manometry with automated oscillometric devices. Design Within the context of a continuing epidemiological study (EPIC-Potsdam Study), blood pressure measurements were performed simultaneously with an aneroid sphygmomanometer and an automated oscillometric device for each subject We randomly selected 400 men and women from the main study population and one observer performed three consecutive blood pressure measurements for each subject according to a standardized procedure. In total, 10 oscillometric devices of the same type were used. Demographic and anthropometric data for each subject were obtained by trained interviewers. Results The mean difference between the aneroid and the oscillometric measurements of systolic blood pressure was 0.2 +/- 5.6 mmHg (aneroid value greater, NS), whereas the mean difference in diastolic blood pressure, 0.5 +/- 3.5 mmHg (aneroid value smaller), attained statistical significance (P = 0.0001), Estimates of prevalence for hypertension differed by 0.4% for women, and by 2.9% for men, Associations with the differences between methods were observed with age, blood pressure, lean body mass, upper arm circumference and specific devices without indicating a strong and consistent pattern. Conclusions The use of automated oscillometric devices in epidemiological studies introduces a bias of very small magnitude compared with use of the aneroid method. The effect of the change to this automated measurement procedure on prevalence estimates is small but might affect comparability of data. Minor differences in measurement performance between devices of one type might affect population parameters. (C) 1998 Lippincott-Raven Publishers.
引用
收藏
页码:739 / 746
页数:8
相关论文
共 50 条
  • [1] Is macronutrient composition of dietary intake data affected by underreporting? Results from the EPIC-Potsdam study
    Voss, S
    Kroke, A
    Klipstein-Grobusch, K
    Boeing, H
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1998, 52 (02) : 119 - 126
  • [2] Is macronutrient composition of dietary intake data affected by underreporting? Results from the EPIC-Potsdam study
    S Voss
    A Kroke
    K Klipstein-Grobusch
    H Boeing
    European Journal of Clinical Nutrition, 1998, 52 : 119 - 126
  • [3] Circulating Omentin as a Novel Biomarker for Colorectal Cancer Risk: Data from the EPIC-Potsdam Cohort Study
    Aleksandrova, Krasimira
    di Giuseppe, Romina
    Isermann, Berend
    Biemann, Ronald
    Schulze, Matthias
    Wittenbecher, Clemens
    Fritsche, Andreas
    Lehmann, Rainer
    Menzel, Juliane
    Weikert, Cornelia
    Pischon, Tobias
    Boeing, Heiner
    CANCER RESEARCH, 2016, 76 (13) : 3862 - 3871
  • [4] Data from the EPIC-Potsdam Study Type 2 Diabetes: Omega-6 Fatty Acids in Lipid Fractions as Biomarkers of Disease Risk
    不详
    AUSTRIAN JOURNAL OF CLINICAL ENDOCRINOLOGY AND METABOLISM, 2023, 16 (02): : 81 - 82
  • [5] Volatile compounds from banana. Comparative study of two extraction methods.
    Cosio, R
    Rene, F
    SCIENCES DES ALIMENTS, 1996, 16 (04) : 383 - 392
  • [6] A comparative study of invasive and oscillometric methods of arterial blood pressure measurement in the anesthetized rabbit
    Ypsilantis, P
    Didilis, VN
    Politou, M
    Bougioukas, I
    Bougioukas, G
    Simopoulos, C
    RESEARCH IN VETERINARY SCIENCE, 2005, 78 (03) : 269 - 275
  • [7] Comparative study of non-invasive blood pressure measurement methods in elderly people
    Fabian, Vratislav
    Janouch, Martin
    Novakova, Lenka
    Stepankova, Olga
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 612 - 615
  • [8] COMPARATIVE STUDY OF TWO AMBULATORY BLOOD PRESSURE MONITORS THAT USE DIFFERING METHODS OF CALIBRATION TO DETERMINE CENTRAL AORTIC BLOOD PRESSURE FROM THE BRACHIAL WAVEFORM
    Hathway, P.
    Butlin, M.
    Turner, M.
    Avolio, A. P.
    JOURNAL OF HYPERTENSION, 2015, 33 : E181 - E182
  • [9] Dispersed decision-making system with fusion methods. from the rank level and the measurement level - A comparative study
    Przybyla-Kasperek, Malgorzata
    Wakulicz-Deja, Alicja
    INFORMATION SYSTEMS, 2017, 69 : 124 - 154
  • [10] Comparative Study for Measurement of Residual Leucocytes in Leucodepleted Red Blood Cells by Two Different Methods
    Prashant Pandey
    Amit Pande
    Divya Setya
    Praveen Kumar
    Ajay Shanker
    Indian Journal of Hematology and Blood Transfusion, 2020, 36 : 740 - 744