Coupling between 3D displacements and rotations at the glenohumeral joint during dynamic tasks in healthy participants

被引:26
|
作者
Dal Maso, Fabien [1 ]
Raison, Maxime [2 ]
Lundberg, Arne [3 ]
Arndt, Anton [3 ,4 ]
Begon, Mickael [1 ]
机构
[1] Univ Montreal, Dept Kinesiol, Lab Simulat & Modelisat Mouvement, Laval, PQ H7N 0B6, Canada
[2] Ecole Polytech, Montreal, PQ H3C 3A7, Canada
[3] Karolinska Inst, Stockholm, Sweden
[4] Swedish Sch Sport & Hlth Sci, Stockholm, Sweden
基金
加拿大自然科学与工程研究理事会;
关键词
Intracortical pin; Shoulder prosthesis; Kinematic model; 3D kinematics; CT-scan; TOTAL SHOULDER ARTHROPLASTY; IN-VIVO; SCAPULAR KINEMATICS; SUBTALAR KINEMATICS; FORMAL METHODS; HUMERAL HEAD; MOTION; TRANSLATION; MODEL; ELEVATION;
D O I
10.1016/j.clinbiomech.2014.08.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Glenohumeral displacements assessment would help to design shoulder prostheses with physiological arthrokinematics and to establish more biofidelic musculoskeletal models. Though displacements were documented during static tasks, there is little information on their 3D coupling with glenohumeral angle during dynamic tasks. Our objective was to characterize the 3D glenohumeral displacement-rotation couplings during dynamic arm elevations and rotations. Methods: Glenohumeral displacements were measured from trajectories of reflective markers fitted on intracortical pins inserted into the scapula and humerus. Bone geometry was recorded using CT-scan. Only four participants were recruited to the experiment due to its invasiveness. Participants performed dynamic arm abduction, flexion and axial rotations. Linear regressions were performed between glenohumeral displacements and rotations. The pin of the scapula of one participant moved, his data were removed from analysis, and results are based on three participants. Findings: The measurement error of glenohumeral kinematics was less than 0.15 mm and 0.2 degrees. Maximum glenohumeral displacements were measured along the longitudinal direction and reached up to +12.4 mm for one participant. Significant couplings were reported especially between longitudinal displacement and rotation in abduction (adjusted R-2 up to 0.94). Interpretation: The proposed method provides the potential to investigate glenohumeral kinematics during all kinds of movements. A linear increase of upward displacement during dynamic arm elevation was measured, which contrasts with results based on a series of static poses. The systematic investigation of glenohumeral displacements under dynamic condition may help to provide relevant recommendation for the design of shoulder prosthetic components and musculoskeletal models. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1048 / 1055
页数:8
相关论文
共 50 条
  • [31] Modeling Static and Dynamic Joint Relationship for 3D Pose Estimation
    Liu, Qiong
    He, Jianhang
    Wen, Jiaxiao
    Beijing Youdian Daxue Xuebao/Journal of Beijing University of Posts and Telecommunications, 2024, 47 (05): : 35 - 43
  • [32] Synergistic coupling between 3D bioprinting and vascularization strategies
    Yeo, Miji
    Sarkar, Anwita
    Singh, Yogendra Pratap
    Derman, Irem Deniz
    Datta, Pallab
    Ozbolat, Ibrahim T.
    BIOFABRICATION, 2024, 16 (01)
  • [33] Glenohumeral Joint Volume Measurement in Patients with Shoulder Instability: A 3D Volumetric Magnetic Resonance Arthrographic Study
    Gueclue, Derya
    Unlu, Elif Nisa
    Arican, Mehmet
    Acar, Oguzhan
    Uludag, Veysel
    Ogul, Hayri
    MEDICINA-LITHUANIA, 2024, 60 (09):
  • [34] Investigation of 3D glenohumeral displacements from 3D reconstruction using biplane X-ray images: Accuracy and reproducibility of the technique and preliminary analysis in rotator cuff tear patients
    Zhang, Cheng
    Skalli, Wafa
    Lagace, Pierre-Yves
    Billuart, Fabien
    Ohl, Xavier
    Cresson, Thierry
    Bureau, Nathalie J.
    Rouleau, Dominique M.
    Roy, Andre
    Tetreault, Patrice
    Sauret, Christophe
    de Guise, Jacques A.
    Hagemeister, Nicola
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2016, 29 : 12 - 20
  • [35] Correlation between 3D microstructural and 2D histomorphometric properties of subchondral bone with healthy and degenerative cartilage of the knee joint
    Lahm, Andreas
    Kasch, Richard
    Spank, Heiko
    Erggelet, Christoph
    Esser, Jan
    Merk, Harry
    Mrosek, Eike
    HISTOLOGY AND HISTOPATHOLOGY, 2014, 29 (11) : 1477 - 1488
  • [36] Impact of plasma response on plasma displacements in DIII-D during application of external 3D perturbations
    Wingen, A.
    Ferraro, N. M.
    Shafer, M. W.
    Unterberg, E. A.
    Evans, T. E.
    Hillis, D. L.
    Snyder, P. B.
    NUCLEAR FUSION, 2014, 54 (06)
  • [37] Glenohumeral translation during active and passive elevation of the shoulder - a 3D open-MRI study
    Graichen, H
    Stammberger, T
    Bonel, H
    Englmeier, KH
    Reiser, M
    Eckstein, F
    JOURNAL OF BIOMECHANICS, 2000, 33 (05) : 609 - 613
  • [38] 3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation
    Balocco, Simone
    Basset, Olivier
    Azencot, Jacques
    Tortoli, Piero
    Cachard, Christian
    MEDICAL PHYSICS, 2008, 35 (12) : 5440 - 5450
  • [39] Comparison of low back joint moment using a dynamic 3D biomechanical model in different transferring tasks wearing low back belt
    Katsuhira, Junji
    Sasaki, Hideaki
    Asahara, Sanae
    Ikegami, Takanori
    Ishihara, Hisako
    Kikuchi, Takashi
    Hirai, Yusuke
    Yamasaki, Yasuyuki
    Wada, Tomohiko
    Maruyama, Hitoshi
    GAIT & POSTURE, 2008, 28 (02) : 258 - 264
  • [40] 3D Analysis of the Proximal Interphalangeal Joint Kinematics during Flexion
    Hess, Florian
    Fuernstahl, Philipp
    Gallo, Luigi-Maria
    Schweizer, Andreas
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013